Inspection history · 79
15 October 2008
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3345797
27 August 2008
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3320492
10 July 2008
Damage Survey
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3264419
3 March 2008
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3157953
2 November 2006
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2812811
21 August 2006
Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2755175
7 April 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2619429
14 March 2006
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2602373
11 January 2006
COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2564745
4 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2450963
25 March 2005
MTSA Verification
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2319237
25 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2319440
10 December 2004
Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2256806
10 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2238518
2 January 2004
Periodic Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1973318
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1983835
8 January 2003
Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1727647
5 July 2002
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1643593
28 December 2001
Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1479073
6 November 2001
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 532746
5 September 2001
Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1071290
20 June 2001
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 510216
15 February 2001
COI Inspection · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1406863
2 February 2000
Re-Inspection · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1045451
11 March 1999
COI Inspection · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1426181
15 May 1998
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1125383
2 September 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 479492
21 August 1997
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1119050
7 May 1997
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1435924
2 August 1996
Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1411348
19 June 1996
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 538653
8 May 1996
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1082222
10 March 1996
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 519916
5 March 1996
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 538993
19 January 1996
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1184369
7 June 1995
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 881616
23 April 1995
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 507983
21 December 1994
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1155241
18 August 1994
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 860890
20 October 1993
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 490046
6 October 1993
Damage Survey · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 832022
28 June 1993
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 845391
21 September 1992
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 527006
15 September 1992
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 954640
6 February 1992
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 500199
23 January 1992
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 465832
9 July 1991
COI Inspection · Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1248173
21 May 1991
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 442644
23 October 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 513625
7 August 1990
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 921465
18 June 1990
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1227111
15 June 1990
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 903491
17 April 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 468948
24 October 1989
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 452635
28 August 1989
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1038046
29 March 1989
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 504858
6 December 1988
Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 896794
17 June 1988
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 892002
25 April 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 493794
25 April 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1034142
31 March 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 533057
29 February 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 437119
29 December 1987
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1005629
13 November 1987
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1023796
22 May 1987
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1026732
21 May 1987
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 496984
16 January 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 524271
4 November 1986
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 512189
19 June 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294435
7 March 1986
Re-Inspection · Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1298125
5 February 1986
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 998363
13 December 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 990699
1 November 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 498087
3 October 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 451292
19 August 1985
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1297220
16 August 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 529554
5 August 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 443112
4 June 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 979670
21 February 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 451042
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 15 October 2008
Resolved
Replace bolts to P/V cap at #9 and #10 tank
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2021
Resolution: Vessel has been out of service since 06OCT2009. Vessel deficiencies closed to clean up unit's open deficiency list. These deficiencies will be reviewed if the vessel decides to come back into service to ensure vessel is in compliance.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 15 October 2008
Resolved
Crop and renew to good steel the riser vent pipe #5 tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2021
Resolution: Vessel has been out of service since 06OCT2009. Vessel deficiencies closed to clean up unit's open deficiency list. These deficiencies will be reviewed if the vessel decides to come back into service to ensure vessel is in compliance.
Construction/Loadline › Hull › Hull Plating
Issued 10 July 2008
Resolved
Stbd bow corner fractured along the entire corner at the deck and approximatly 3' down from the deck.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2008
Construction/Loadline › Structures › Manhole
Issued 8 January 2003
Resolved
Twenty void single dog hatch covers missing the dogs.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 15 January 2003
Resolved 8 January 2003
Resolution: All dogs replaced.
Deck/Cargo › Cargo Heating
Issued 8 January 2003
Resolved
Fractured blank flange on the steam line.
Condition: Unknown
Due 15 January 2003
Resolved 8 January 2003
Resolution: Replaced.
Stability › Watertight Integrity
Issued 28 December 2001
Resolved
Hatch dog missing. Fixed during inspection LEGACY COMPONENT DESC: hatch dogs missing
Condition: Unknown
Due 28 December 2001
Resolved 28 December 2001
Resolution: Fixed during inspection
Construction/Loadline
Issued 28 June 1993
Resolved
MAKE PERMANENT REPAIRS TO EIGHT INCH FRACTURE IN NO. 3 STARBOARD VOID IN WAY OF DECK KNUCKLE. MAINTAIN TEMPORARY REPAIRS.
Condition: Unknown
Due 28 June 1993
Resolved 28 June 1993
Construction/Loadline
Issued 18 June 1990
Resolved
MAKE PERMANENT REPAIRS TO 24" FRACTURE IN WAY OF STERN AT STBD CORNER, FROM DECK EDGE TO 10' DRAFT LINE.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Construction/Loadline
Issued 15 June 1990
Resolved
STRIP AND LOCATE SOURCE OF EXCESSIVE WATER IN NO. 1 THRU NO. 5 PORT AND STBD WING VOIDS.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Construction/Loadline
Issued 15 June 1990
Resolved
REPLACE ALL MISSING BOLTS IN WAY OF WING VOID DECK CLOSURE DEVICES.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Deck/Cargo
Issued 25 April 1988
Resolved
MAKE PERMANENT REPAIRS TO LEAKING CARGO PUMP PACKING PRIOR TO LOADING NEXT CARGO BUT NO LATER THAN 25 MAY 1988.
Condition: Unknown
Due 25 April 1988
Resolved 25 April 1988
Construction/Loadline
Issued 22 May 1987
Resolved
MAKE PERMANENT REPAIRS TO 6" FRACTURE AT DECK IN WAY OF PORT BOW CORNER WRAPPER AT NEXT GAS FREE AVAILABILITY BUT NOT LATER THAN 30NOV87.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Construction/Loadline
Issued 22 May 1987
Resolved
MAKE PERMANENT REPAIRS TO 6" DECK KNUCKLE FRACTURE IN WAY OF #2 STBD VOID CAVEL AT NEXT GAS FREE AVAILABILITY BUT NOT LATER THAN 30NOV87.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Construction/Loadline
Issued 4 June 1985
Resolved
RENEW ALL MISSING WING VOID HATCH COVER BOLTS (PORT AND STARBOARD) PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 4 June 1985
Resolved 4 June 1985
Construction/Loadline
Issued 4 June 1985
Resolved
MAKE AND MAINTAIN TEMPORARY REPAIRS TO THE FOLLOWING FRACTURES PRIOR TO LOADING OF CARGO BUT NOT LATER THAN COMPLIANCE DATE: 1) 2' HORIZONTAL FRACTURE AT DECK IN STARBOARD BOW CORNER. 2) 1' VERTICAL FRACTURE IN WAY OF 10' DRAFT ON PORT STERN CORNER WRAPPER.
Condition: Unknown
Due 4 June 1985
Resolved 4 June 1985
Construction/Loadline
Issued 4 June 1985
Resolved
MAKE PERMANENT REPAIRS TO THE FOLLOWING FRACTURES AT THE NEXT GAS FREE BUT NOT LATER THAN COMPLIANCE DATE: 1) 2' HORIZONTAL FRACTURE AT DECK IN STARBOARD BOW CORNER. 2) 1' VERTICAL FRACTURE IN WAY OF 10' DRAFT ON PORT STERN CORNER WRAPPER.
Condition: Unknown
Due 4 June 1985
Resolved 4 June 1985