MAURY USCG vessel records
← All vessels

FLYER

FLYER is a 1994 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in March 2026, along with 53 deficiencies, 1 operational control and 3 casualty investigations between 2016 and 2019.

Records from 2016 to 2026. Most recent: inspection, 12 March 2026.

Built
1994
Last inspected
12 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCJ6148
405752
Flag
UNITED STATES
Maury page id
psix-405752

Documentation record

Registered dimensions (L × B × D)57.0 ft × 31.0 ft × 7.0 ft
Registered tonnagegross 26 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGREENE MARINE INC · YARMOUTH, ME, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 4 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Simplified, Gross Ton
21 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

12 March 2026 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8325209
4 March 2026 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8321212
29 January 2025 COI Inspection · Administrative Inspection · DAPI Audit · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8072379
1 November 2024 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8070928
18 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7936544
11 April 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7659274
12 October 2022 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7573299
27 April 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7438333
15 October 2021 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7332469
9 August 2021 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7281525
14 April 2020 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6926060
24 October 2019 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6835604
16 July 2019 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6752589
12 July 2019 Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6747390
16 May 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6659578
11 January 2019 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6616969
8 May 2018 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6408775
9 January 2018 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6334699
14 April 2017 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6123118
28 November 2016 Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6048756
12 April 2016 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5851592
11 April 2016 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5851831
25 January 2016 Internal Structural Exam · Drydock Extension · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5802623

Deficiency record · 53

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 November 2024 Resolved
Vessel must complete Drydock Exam and Internal Structural Exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2025
Resolution: Vessel completed satisfactory DD & ISE to satisfaction of local MSU STT OCMI.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 June 2024 Resolved
Provide 02 additional hand red flare distress signals so there are a total of 06 on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2024
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 June 2024 Resolved
Due to high winds, vessel unable to get underway for propulsion, sail, and steering tests as well as emergency drills. Conduct underway tests and drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 June 2024 Resolved
Fire pump rattles and makes a loud grinding noise when engaged. Service the pump's bearings or replace pump to prevent potential pump failure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2024
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 18 June 2024 Resolved
Provide a visual indicator for the starboard engine room bilge high level alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 June 2024 Resolved
Install a positive shutoff valve at the hull penetration of the port and starboard aft automatic submersible bilge pump discharge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 June 2024 Resolved
Abandon ship, man overboard, and fire fighting drills must be conducted and logged at least once every 3 months. Conduct and log drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 June 2024 Resolved
Starboard aft bilge pump was not operational. Vessel mechanic cleaned and tightened wire connections and tested sat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 June 2024 Resolved
Seal the cable run in the starboard engine room aft bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 June 2024
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 April 2023 Resolved
Due to high winds, vessel unable to get underway for propulsion, sail, and steering tests as well as emergency drills. Conduct underway tests and drills within 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 October 2022 Resolved
The starboard backstay chainplate has a stress fracture in the upper load bearing area. Replace chainplate in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 October 2022 Resolved
Conduct post Mast Inspection sea trials.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 27 April 2022 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Install guards in front of or covering the rotating machinery on the port and starboard engines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 29 July 2022
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 27 April 2022 Resolved
Provide a battery powered bullhorn.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 August 2021 Resolved
Make the port lazarette hatch watertight prior to August 26, 2021.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 August 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 August 2021 Resolved
Your vessel must undergo an annual inspection with the 3 months before or after each anniversary date. Vessel is overdue for annual inspection. Anniversary date is 14APR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2020 Resolved
Submit electrical drawings to the Coast Guard at [email withheld] for newly installed 12volt power source under operating station for vital systems (note vessel name and Official Number). Include Manufacture specifications for battery bank, switches, over current protection, battery charger, wire run length, wire size, wire type and connection to house panel if applicable. Following approval, Coast Guard will re-attend Vessel to certify proper installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2020
Resolution: plan submitted and installed per 183.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 April 2020 Resolved
Make collision bulkhead on STBD side watertight (penetration for electrical wire).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 May 2020
Resolution: Penetration sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 April 2020 Resolved
Replace retro-reflective tape (SOLAS) on 36 Adult and 06 Child PFDS, tape was found wasted and no longer reflective.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 May 2020
Resolution: New SOLAS tape applied
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 April 2020 Resolved
Provide 02 portable lights for vessel, 01 shall be stored at operating station and 01 shall be in the vicinity/access of the machinery space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 May 2020
Resolution: Flash lights provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 April 2020 Resolved
Repair/replace set screws in furling foil on jibstay, screws were missing on bottom foil.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 May 2020
Resolution: Screws replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 24 October 2019 Resolved
Repair soft spot locations identified (upper platform, on forward deck in front of storage/benches, vertical section under port window next to mast. all areas of cross member attachments with the exception of the aft one on the port side, and all other self identified locations), submit repair proposal to include material type (Glass type, weight, and resin). Area must be properly prepped and ground down to good glass prior to carrying out repairs.
Action required: 705 - Other - as specified
Resolved 14 November 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 October 2019 Resolved
Seal inboard hull penetrations into the engine room for a watertight in the watertight envelope.
Action required: 705 - Other - as specified
Resolved 10 December 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 October 2019 Resolved
Seal penetrations into the engine rooms for a vapor tight seal (from aft compartment and where hose penetrates the deck above.
Action required: 705 - Other - as specified
Resolved 10 December 2019
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 24 October 2019 Resolved
Provide drawings of new items to attached to deck (i.e. bar) with weight difference to local [name withheld] installed new deck and seating measurements will need to be completed by local OCMI for passenger count.
Action required: 705 - Other - as specified
Resolved 14 November 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 October 2019 Resolved
Vessels rudder post found with crevice corrosion near rudder and minor crevice corrosion found on upper portion before sleeve. Rudder post will be removed for re-inspection NLT 24 APRIL 2020. Local Marine Inspectors will evaluate the condition for any changes.
Action required: 705 - Other - as specified
Resolved 18 November 2019
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 May 2019 Resolved
Valid COD must be kept on board at all times.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2019
Resolution: Copy provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2019 Resolved
Replace 01 adult PFDs, vessel is restricted to carrying 68 total persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: New Adult PFD onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 May 2019 Resolved
Provide metallic positive shutoff valves at hull penetration for all installed submersible bilge pumps.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 May 2019
Resolution: Metallic valves installed at hull.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2019 Resolved
Provide over-current protection device to all wires connected directly to battery terminal within 72 inches of wire run to battery terminal. STBD Battery
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: Inline fuse installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2019 Resolved
All connections to battery terminals shall be made with permanent type connectors, wing nuts are not permanent type. STBD Battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: Wingnuts removed.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 16 May 2019 Resolved
Provide hatch for securing Engine Room door on STBD side, and close bulkhead penetrations on portside to prevent vapors from entering accommodation space (Head).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: Completed
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 May 2019 Resolved
Provide light cover on light fixture in STBD forward compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: Cover installed.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 16 May 2019 Resolved
Cracks discovered on STBD lower shroud chain plate, make connection point available for re-inspection and to conduct NDT (Dye pen) in the presence of attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: NDT conducted, additonal 835 issued.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2019 Resolved
Remove STBD collision bulkhead panel for forward compartment inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: Cover removed, inspected with no deficiencies.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2019 Resolved
Multiple hairline cracks are visible in both Port and STBD stainless steel shroud chain plates, NDT (Dye pen) was conducted in the presence of attending [name withheld] confirmed cracks were not superficial or just surface cracks. Aluminum cross-member connection point for jib-stay was found to be fatigued and elongated an estimated 1/4inch. Provide plan for repair/replace for all lower standing rigging chain-plates and connection points.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 June 2019
Resolution: Additional CG835 issued.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 16 May 2019 Resolved
Provide adequate ventilation for batteries, batteries currently installed in port and STBD lazarette producing unsafe levels of LEL due to charging and lack of ventilation for hydrogen gas.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2019
Resolution: Batteries relocated to E/R
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2019 Resolved
Provide access to attending Marine inspector to visually inspect fastener penetrations when chain plates are removed. Replacement of port and STBD chain plates shall be visually inspected after installation. Retain old fasteners for examination. *Prior to credit drydock
Action required: 705 - Other - as specified
Resolved 26 June 2019
Resolution: Added special note to vessel, must be completed prior to recieving credit drydock.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2019 Resolved
Provide access to attending Marine inspector to visually inspect and measure Aluminum cross-member connection point for jib-stay by removing the clevis pen from the toggle prior to any repair or fabrication. *Prior to credit Drydock
Action required: 705 - Other - as specified
Resolved 26 June 2019
Resolution: Added special note to vessel, must be completed prior to recieving credit drydock.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 8 May 2018 Resolved
Replace/renew port Buoyant Apparatus. BA is not in good serviceable condition, lifeline attachment points degrading.
Action required: 705 - Other - as specified
Due 8 August 2018
Resolved 17 August 2018
Resolution: New 22 person life float on board.
Navigation › Piloting/Steering › Magnetic Compass
Issued 8 May 2018 Resolved
Repair/replace light on magnetic compass.
Action required: 705 - Other - as specified
Due 8 June 2018
Resolved 8 June 2018
Resolution: Light on compass is operational.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 May 2018 Resolved
Post emergency instructions.
Action required: 705 - Other - as specified
Due 8 June 2018
Resolved 8 June 2018
Resolution: Instructions posted.
Engineering › Steering Gear System › Cable
Issued 8 February 2018 Resolved
Repair steering gear assembly prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2018
Resolution: Steering gear assembly repaired.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 February 2018 Resolved
Repair cracked welds on passenger embarkation/disembarkation ladder.
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 1 March 2018
Resolution: Cracked welds repaired.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 April 2017 Resolved
Provide GPS input for VHF radio.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 19 May 2017
Resolution: GPS integrated into VHF radio.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 14 April 2017 Resolved
Replace fixed gas fire system tanks for both port and starboard installations. Manufacture dates are 1994.
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 28 April 2017
Resolution: New fixed fire system tanks were installed, verified coverage of area to be the same as previous installation (200ft3). Conducted operational test of both systems.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 April 2017 Resolved
Provide plans to OCMI to install 4" rail courses on vessel.
Action required: 705 - Other - as specified
Due 14 May 2017
Resolved 19 May 2017
Resolution: Deck rail courses installed at 4" intervals.
Engineering › Steering Gear System › Rudder
Issued 28 November 2016 Resolved
Starboard rudder broken off.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2016
Resolved 9 December 2016
Resolution: Rudder Replaced
Engineering › Steering Gear System › Rudder
Issued 28 November 2016 Resolved
Rudder stop on port side has broken off.
Action required: 705 - Other - as specified
Due 28 December 2016
Resolved 9 December 2016
Resolution: rudder stop replaced.
Documentation › Certificates/Documents › FCC SSL
Issued 12 April 2016 Resolved
Provide valid FCC SSL.
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 12 April 2016
Resolution: Vessel retrieved valid FCC SSL from office.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 12 April 2016 Resolved
Provide a donning placard for each type of lifejacket on board.
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 12 April 2016
Resolution: Vessel printed and posted a donning placard for each type of lifejacket on board.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Valve
Issued 25 January 2016 Resolved
Engine cooling intake valve would not close completely, required to be fixed or replaced prior to DD credit.
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 22 February 2016
Resolution: Valve repaired.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 25 January 2016 Resolved
Provide new shaft, propeller, and bearings for inspection prior to drydock credit.
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 22 February 2016
Resolution: Witnessed installation of new shaft, bearings, propeller.

Casualty record · 3

11 April 2016Routine · role: Involved in a Marine Casualty · activity 5851831
11 January 2019Routine · role: Involved in a Marine Casualty · 1 injured · activity 6616969
30 June 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6734597
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record