Records from 1994 to 2008. Most recent: inspection, 15 September 2008.
Inspection history · 16
15 September 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3325321
15 September 2008
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3325346
13 September 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3324041
13 September 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3328037
10 September 2008
Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3317150
26 May 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 403968
4 May 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 403339
2 January 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 398818
28 April 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 390675
28 April 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 455399
6 April 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 391926
17 June 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 379634
3 October 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1182041
3 September 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 370216
3 September 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 861978
27 May 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 367045
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 15 September 2008
Resolved
The main engine electronic control unit that manages the controllable pitch of the propeller system had a failure of a fuse. This caused a loss of power to the main engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 September 2008
Resolved 15 September 2008
Resolution: Received proper documentation from Germanischer Lloyd satisfying requirement.
Engineering › Fuel Oil Service System › Piping
Issued 10 September 2008
Resolved
Temporary patch placed on fuel oil supply line for the MDE. Make permanent repairs to the satisfaction of the attending class surveyor.
Action required: 705 - Other - as specified
Due 17 September 2008
Resolved 15 September 2008
Resolution: Received proper documentation from Germanischer Lloyd satisfying requirement.
Engineering › Fuel Oil Service System › Piping
Issued 10 September 2008
Resolved
Fuel oil soaked lagged on MDE fuel oil supply line. Remove and replace lagging to the satisfaction of the attending class surveyor.
Action required: 705 - Other - as specified
Due 24 September 2008
Resolved 15 September 2008
Resolution: Received proper documentation from Germanischer Lloyd satisfying requirement.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 10 September 2008
No resolution recorded
Chief Engineer could not provide documentation of hydrostatic test of bunkering lines. Vessel to provide documentation of proof of hydrostatic test IAW 33 CFR 156.170 prior to bunking or transfering fuel in US waters.
Action required: 703 - Prior to bunkering operations
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 September 2008
No resolution recorded
X-band radar is inop. Provide techicians report that radar is operatingn as expected to the USCG.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving
Issued 4 May 1997
Resolved
UPDATE ONBOARD SOLAS TRAINING MANUAL IAW SOLAS CH III REG 51 PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 26 May 1997
Resolved 26 May 1997
Construction/Loadline
Issued 4 May 1997
Resolved
PROVIDE EVIDENCE OF CLASS VERIFICATION OF SATISFACTORY 15PPM OWS AND ALARM TEST PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 26 May 1997
Resolved 26 May 1997
Engineering
Issued 27 May 1994
Resolved
VESSEL DOES NOT HAVE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 31 May 1994
Resolved 31 May 1994
Navigation
Issued 27 May 1994
Resolved
MANEUVERING FACT SHEET DOES NOT CONTAIN TABLE OF SPEEDS AT WHICH BOW THRUSTER IS EFFECTIVE.
Condition: Unknown
Due 3 September 1994
Resolved 3 September 1994
Navigation
Issued 27 May 1994
Resolved
BLOCK DIAGRAM OPERATING INSRUCTIONS FOR STEERING GEAR CHANGE OVER NOT DISPLAYED ON THE BRIDGE.
Condition: Unknown
Due 3 September 1994
Resolved 3 September 1994
Documentation
Issued 27 May 1994
Resolved
VESSEL DOES NOT HAVE OIL POLLUTION PLACARD POSTED.
Condition: Unknown
Due 31 May 1994
Resolved 31 May 1994