MAURY USCG vessel records Sign in
← All vessels

MING HANG 5

MING HANG 5 is a 1990 freight ship. The Coast Guard has recorded 20 inspections since 1994, most recently in April 2017, along with 16 deficiencies — 2 with no resolution recorded — and 2 operational controls.

Records from 1994 to 2017. Most recent: inspection, 10 April 2017.

Built
1990
Last inspected
10 April 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8921470 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
406026
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-406026

Inspections, by type

…with no type recorded9
Years with a record 8 calendar years (1994–2017)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it5253 - Convention (Subpart B), Net Ton
10405 - Convention (Subpart B), Gross Ton
16958 - Displacement, Metric Ton
10742 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

10 April 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6121250
28 December 2015 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5787963
2 May 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3197458
28 October 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1931945
4 August 2003 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1866435
29 July 2003 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1860872
28 July 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1861551
28 July 2003 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1866235
14 July 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1846185
19 May 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1796594
7 May 2003 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1788306
5 May 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1787589
12 June 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1629124
1 February 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 274183
28 October 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 384707
15 September 1995 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 382550
1 May 1995 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 377855
27 February 1995 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 375659
28 December 1994 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 373624
28 December 1994 MARPOL Annex I Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1161905

Deficiency record · 16

Fire Fighting › Structural - A Class Divisions › Aux Spaces (little/no fire risk)
Issued 10 April 2017 No resolution recorded
CODE: 0750 CITE: 74SOLAS(97 CONS.)II-2/3.3 ACTION: 40ac "A" CLASS DIVISIONS ARE THOSE DIVISIONS FORMED BY BULKHEADS AND DECKS WHICH COMPLY WITH THE FOLLOWING: THEY SHALL BE CONSTRUCTED AS TO BE CAPABLE OF PREVENTING THE PASSAGE OF SMOKE AND FLAME TO THE END OF THE ONE-HOUR STANDARD FIRE TEST. PSC EXAMINER IDENTIFIED NUMEROUS CLASS "A" BULKHEAD PENETRATIONS IN MULTIPLE SPACES IN THE HOUSE.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 April 2017 No resolution recorded
CODE: 0799 CITE: 74SOLAS(97 CONS.)II-2/20.1 ACTION: 40ac IN ALL SHIPS GENERAL ARRANGEMENT PLANS SHALL BE PERMANENTLY EXHIBITED FOR THE GUIDANCE OF THE SHIPS'S OFFICERS. THE FIRE PLAN WAS NOT ACCURATE FOR THE RICE STORAGE ROOM ON THE MAIN DEK THAT HAS BEEN REDESIGNATED AS ELECTRICAL STORAGE.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 28 October 2003 Resolved
COMPANY TO PROVIDE PLANNED MAINTENANCE SYSTEM. CURRENTLY FULL BURDEN OF MAINTENANCE PLANNING IS THE RESPONSIBILITY OF THE CREW. MSD LEAKED FECAL MATTER DUE TO BROKEN VALVE. REPAIR AND OPERATION OF PLANT NOT CLEARLY DEFINED. LEGACY COMPONENT DESC: Company Responsibilities/Authority
Action required: 705 - Other - as specified
Due 28 November 2003
Resolved 18 December 2005
Resolution: MSD inspected by Coast Guard Marine Inspector and no leaks observed. ISM examined with no discrepancies.
Engineering › Sea-water System (primary cooling) › Pump
Issued 28 October 2003 Resolved
REPACK THE BELOW GLANDS TO THE SATISFACTION OF CLASS NOT LATER THAN 28NOV03: a) PORT SERVICE COOL S/W PUMP, b) A/C COOL WATER PUMP, c) DIST PLANT EJECTOR PUMP, AND d) #2 F/W PUMP. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 November 2003
Resolved 18 December 2005
Resolution: New discrepancies issued to the vessel for leaking pumps, see activity number 2553046.
Operations/Management › Vessel Safety Management
Issued 29 July 2003 Resolved
Master and Chief engineer shall work together to develop a non- conformity report stating planned maintenence system needs to be improved by company management. To date the burdon of planned maintence falls to the crew. LEGACY COMPONENT DESC: Plans for Shipboard Operations
Condition: Unknown
Due 15 August 2003
Resolved 28 October 2003
Resolution: Item re-issued during AEF on 10/28/03 to be reviewed by Class.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 29 July 2003 Resolved
The discharge water outlet valve was found to be broken. Vessel was instructed to have entire sewage plant overhauled and inspected to satisfaction of class
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 July 2003
Resolved 30 July 2003
Resolution: Repairs made and inspected by class
Lifesaving
Issued 1 February 2000 Resolved
Replace 3 lifebouys located in variouslocations on vessel.
Condition: Unknown
Due 2 February 2000
Resolved 2 February 2000
Lifesaving
Issued 1 February 2000 Resolved
Replace 6 immersion suits located in embarkation storage locker.
Condition: Unknown
Due 2 February 2000
Resolved 2 February 2000
Lifesaving
Issued 1 February 2000 Resolved
Replace all food rations in Port and Starboard lifeboats.
Condition: Unknown
Due 2 February 2000
Resolved 2 February 2000
Lifesaving
Issued 15 September 1995 Resolved
VESSEL MISSING TWO SELF-IGNITING LIGHTS ON RING LIFEBUOYS.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Lifesaving
Issued 15 September 1995 Resolved
ALL OF VESSEL'S INFLATABLE LIFERAFTS OVERDUE FOR ANNUAL INSPECTION. AS PERCOTP, VESSEL'S CLASS SOCIETY SURVEYOR EXTENDED INSPECTION DATE UNTIL NEXT PORT CALL BUT NOT LATER THAN 05OCT95. THEREFORE, VSL'S LIFERAFTS MUST BE SERVICED BY AN AUTHORIZED LIFERAFT FACILITY PRIOR TO NEXT PORT OR 05OCT95.
Condition: Unknown
Due 9 November 1995
Resolved 9 November 1995
Lifesaving
Issued 28 December 1994 Resolved
_x001C_
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Documentation
Issued 28 December 1994 Resolved
TRANSFER PROCEDURES DID NOT LIST THE NUMBER OF CREW NEEDED FOR OPERATION.
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Documentation
Issued 28 December 1994 Resolved
NO PROCEDURES FOR TOPPING OFF OF THE FUEL TANKS WERE IN THE TRANSFER PROCEDURES.
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Documentation
Issued 28 December 1994 Resolved
TRANSFER PROCEDURES DID NOT IDENTIFY THE DUTIES OF EACH INDIVIDUAL BY THEIRSPECIFIC TITLE. _x001C_
Condition: Unknown
Due 28 December 1994
Resolved 28 December 1994
Documentation
Issued 28 December 1994 Resolved
VESSEL'S TRANSFER PROCEDURES DID NOT HAVE THE NRC PHONE NUMBER OR TO CONTACT THE CG THROUGH VHF16.
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995

Ownership record