Inspection history · 49
8 September 2011
Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4140270
9 June 2011
MTSA Verification · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4031194
8 September 2010
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3845325
3 March 2010
Deficiency Check
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3689656
27 January 2010
Administrative Inspection
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3684707
14 September 2009
Annual Inspection · Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3595627
1 October 2008
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3336438
2 October 2007
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3071937
13 September 2006
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2777544
19 September 2005
COI Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2496131
21 June 2005
MTSA Verification
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2397639
9 May 2005
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2353353
15 April 2005
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2338026
8 April 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2329354
16 September 2004
Periodic Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2197528
9 September 2004
Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 2191224
25 August 2003
Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1886839
3 February 2003
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1739471
15 August 2002
Administrative Inspection · Annual Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1666830
2 August 2001
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1071004
7 September 2000
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1399440
13 August 1999
Re-Inspection · Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1408356
18 February 1999
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1130558
5 August 1998
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1404595
13 August 1997
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 782855
13 August 1996
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1452194
5 September 1995
Re-Inspection · Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 874622
22 August 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1188356
29 August 1994
Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 861302
16 February 1994
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 859071
9 February 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 644006
27 January 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 42537
27 January 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 440296
27 January 1994
Damage Survey
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1163254
5 August 1993
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 846804
9 April 1993
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 508375
11 August 1992
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1255523
22 January 1992
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 957345
14 August 1991
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 939365
14 August 1991
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 942623
14 February 1991
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 477403
8 August 1990
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1219773
25 April 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 452735
30 August 1989
COI Inspection · Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1344650
2 August 1988
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 891491
24 June 1987
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1314685
13 August 1986
Credit Drydock · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 998708
19 March 1986
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1305137
14 August 1985
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1300591
Documentation › Markings/Placards › Warning Signs
Issued 9 June 2011
Resolved
Replace or Repair warning signs to make them more visible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2011
Resolved 13 July 2011
Resolution: Signs replaced to meet the regulations.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 9 June 2011
Resolved
Provide a non-conducting deck covering at the electrical panels
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2011
Resolved 13 July 2011
Resolution: Non-conducting mat was placed in front of electrical panels to meet regulations.
Engineering › Fuel Oil Service System › Hose
Issued 9 June 2011
Resolved
Replace fuel supply hose on generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2011
Resolved 13 July 2011
Resolution: Fuel supply line was replaced.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 9 June 2011
Resolved
Provide updated Transfer Procedures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2011
Resolved 8 September 2011
Resolution: Item cleared during follow-up inspection
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 9 June 2011
Resolved
Provide gooseneck vent on starboard aft tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2011
Resolved 13 July 2011
Resolution: Vent was made into a gooseneck to meet the regulations.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 9 June 2011
Resolved
Provide a shutoff valve installed in the fuel supply line of the generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2011
Resolved 13 July 2011
Resolution: Shutoff valve installed in the fuel supply line of the generator.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 June 2011
Resolved
Install heat protection on the exhaust manifold.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2011
Resolved 13 July 2011
Resolution: Heat protections was installed on the exhaust manifold to meet regulations.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 9 June 2011
Resolved
Provide proof of the vessel's Notice of Intent for the VGP. [name withheld], [phone withheld], [email withheld]
Sector Ohio Valley, Kentucky
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 July 2011
Resolved 14 June 2011
Resolution: Verified electronic NOI application on EPA website.
Engineering › Generator (propulsion/auxiliary-electric) › Heating Element Circuitry
Issued 9 June 2011
Resolved
Provide proof of the block heater being hard wired instead of plugged to an extension cord.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 July 2011
Resolved 9 August 2011
Resolution: Received email that block heater has been removed and is no longer in use.
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 9 June 2011
Resolved
Proved proof of proper operation of the temperature gauge on the generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2011
Resolved 13 July 2011
Resolution: Replaced temperature gauge to meet regulations.
Electrical › Electric Generation Source (service) › Generator
Issued 9 June 2011
Resolved
Install overcurrent protection on the service generator to meet the regulations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 August 2011
Resolved 8 September 2011
Resolution: Item cleared during follow-up inspection.
Electrical › Electrical Distribution System (service) › Cable
Issued 27 January 2010
Resolved
Remove all dead end and unused wiring.
Action required: 705 - Other - as specified
Due 27 February 2010
Resolved 3 March 2010
Resolution: All dead end and unused wiring has been removed from barge.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 September 2009
Resolved
Prior to conducting cargo operations, ensure fire extinguishers (3) are hydrostatically tested in accordance with NFPA 10.
Action required: 705 - Other - as specified
Resolved 15 October 2009
Resolution: All fire extinguishers were hydrostatically tested in accordance with NFPA 10.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 14 September 2009
Resolved
Ensure electrical installations on the barge are complient with requirements for hazardous locations in accordance with 46CFR111.105-31(i).
Action required: 705 - Other - as specified
Due 15 December 2009
Resolved 27 January 2010
Resolution: Amended COI, no longer required compliance with 46CFR111.105-31(i)
Deck/Cargo
Issued 22 August 1995
Resolved
UPON OFFLOAD AND PRIOR TO RELOAD, DETERMINE SOURCE OF CARGO LEAK/S INTO THEBOW AND STERN VOIDS. COMPLETE REPAIRS TO THE SATISFACTION OF THE COGNIZANTOCMI, REPAIRS TO BE COMPLETED NO LATER THAN 22 SEPTEMBER 1995. NOTIFY OCMIPRIOR TO COMMENCING REPAIRS.
Condition: Unknown
Due 22 August 1995
Resolved 22 August 1995
Deck/Cargo
Issued 27 January 1994
Resolved
UPON OFFLOADING CARGO, MAKE VESSEL GAS-FREE AND PRESENT FOR INSPECTION AND REPAIR OF CARGO TANK LEAK IN WAY OF NO. 2 STARBOARD CARGO TANK.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Deck/Cargo
Issued 14 August 1985
Resolved
REPAINT RED FLAG.
Condition: Unknown
Due 14 August 1985
Resolved 14 August 1985
Electrical
Issued 14 August 1985
Resolved
REPLACE TORN BATTERY CABLE LEADING FROM BATTERIES TO GENERATOR.
Condition: Unknown
Due 14 August 1985
Resolved 14 August 1985
Construction/Loadline
Issued 14 August 1985
Resolved
REPAINT DRAFT MARKS.
Condition: Unknown
Due 14 August 1985
Resolved 14 August 1985