Records from 1994 to 2002. Most recent: inspection, 3 October 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
3 October 2002
Deficiency Check
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1683693
9 September 2002
Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1673204
9 August 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1449496
2 January 2001
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 825036
17 July 2000
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 820667
17 July 2000
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1448148
21 October 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 790454
29 July 1999
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1397215
15 June 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 810774
11 May 1999
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1397166
27 July 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1449088
30 July 1997
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1394847
25 July 1997
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1116240
25 July 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1439764
5 October 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 873330
11 September 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 884007
31 August 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1394371
22 June 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 886024
29 July 1994
Initial Certification · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1177594
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 9 September 2002
Resolved
Ensure portable fire extinguishers are serviced prior to carrying passengers. LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 9 October 2002
Resolved 13 September 2002
Engineering
Issued 17 July 2000
Resolved
Fabricate means to operate the emergency fuel shut-off in accordance with 46CFR 182.455(b)(4) no later thean 20 Aug 00
Condition: Unknown
Due 20 August 2000
Resolved 31 August 2000
Fire Fighting
Issued 17 July 2000
Resolved
Acquire and provide proof to attending marine inspector of reg'd 3-2.5 gallon buckets for firefighting
Condition: Unknown
Due 20 August 2000
Resolved 31 August 2000
Lifesaving
Issued 17 July 2000
Resolved
Acquire first aid kit in accordance with 46 CFR 160 NLT 20 AUG00
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Engineering
Issued 17 July 2000
Resolved
Place two hose clamps on both port and STBD fuel intake lines NLT 25 JUl 00_x001C_
Condition: Unknown
Due 25 July 2000
Resolved 31 August 2000
Electrical
Issued 17 July 2000
Resolved
Remove all dead end wiring and ensure proper electrical connection under_x001C_ the operating station NLT 20 AUG 00
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Fire Fighting
Issued 29 July 1999
Resolved
INSTALL FIRE DETECTING SYSTEM AS REQUIRED BY 46 CFR 181.400(c). SYSTEM TO BE INSTALLED AS PER 46 CFR 76.27.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 29 July 1999
Resolved
INSTALL RETROREFLECTIVE TAPE ON LIFE RING,(4 PLACES, EVENLY SPACED, BOTH SIDES, FULL WIDTH, 2 INCHES WIDE) AS REQUIRED BY 46 CFR 185.604(i).
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Fire Fighting
Issued 29 July 1999
Resolved
CORRECT FIXED GAS FIRE EXTINGUISHING SYSTEM TO COMPLY WITH 46 CFR 181.400, 181.410, AND 181.420.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 11 May 1999
Resolved
INSTALL FLAMMABLE VAPOR DETECTION SYSTEM, AS PER 46 CFR 182.480 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 11 May 1999
Resolved
REPAIR 4"X2" FRP AREA THAT IS PEELING AWAY FROM PLYWOOD TRANSOM.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 11 May 1999
Resolved
INSTALL HIGH BILGE ALARM AS PER 46 CFR 182.530 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Electrical
Issued 11 September 1995
Resolved
REPLACE ALL NON-MARINE (ROMEX) WIRING THROUGHOUT VESSEL PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 11 September 1995
Resolved 11 September 1995
Accommodation/Occupational Safety
Issued 31 August 1995
Resolved
PROVIDE INSECT SCREEN FOR POTABLE WATER TANK.
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Electrical
Issued 31 August 1995
Resolved
REMOVE DEAD-ENDED WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Engineering
Issued 31 August 1995
Resolved
PROVIDE MACHINERY GUARD FOR PROPULSION ENGINE.
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Lifesaving
Issued 31 August 1995
Resolved
PROVIDE LABEL SHOWING NUMBER OF LIFE JACKETS IN STORAGE AREAS
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Construction/Loadline
Issued 31 August 1995
Resolved
PROVIDE CHECK VALVE IN BILGE LINE.
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995