MAURY USCG vessel records
← All vessels

BARUC

BARUC is a 1991 tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in September 2023, along with 20 deficiencies.

Records from 2016 to 2023. Most recent: inspection, 12 September 2023.

Built
1991
Last inspected
12 September 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 September 2023
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8818805
406234
Flag
PANAMA
Maury page id
psix-406234

Documentation record

Tonnage as PSIX records it4691 - Convention (Subpart B), Gross Ton
1407 - Convention (Subpart B), Net Ton
4380 - Dead Weight, Metric Ton
7141 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

13 inspections, each with its date, unit and type; 20 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

12 September 2023 Deficiency Check
Physical examination · Liquefied Gas Carrier National Center of Expertise · Activity 7790164
22 January 2018 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6341294
9 January 2018 Ballast Water Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6331525
20 November 2017 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6305685
27 September 2017 PII Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6267870
31 May 2017 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6161363
17 May 2017 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6148659
11 May 2017 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6137880
11 October 2016 Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6014094
15 September 2016 Ballast Water Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5984786
9 June 2016 ISPS III Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5896428
8 February 2016 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5811672
13 January 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5792435

Deficiency record · 20

Engineering › Generator (propulsion-electric) › Switch
Issued 9 January 2018 Resolved
1430-Aux Eng-Each Emergency Gen set arranged to be auto started shall be equipped w/ starting device approved by the Admin w/ stored energy capability of at least 3 consecutive starts. A 2nd source of energy shall be provided for an additional 3 starts within 30 min unless manual starting can be demonstrated to be effective. Primary starting done by battery, secondary means by air compressor/receiver, crew unable to start E-gen by air. 74 SOLAS(04) II-1/44.2 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2018
Resolution: Crew replaced the starting button on the E-gen that allows the air to turn crankshaft and start the prime mover.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 9 January 2018 Resolved
0750-Fire Prevention-The construction of all doors and frames in "A" class div shall provide resistance to fire as well as to the passage of smoke and flame. Various doors in eng room have installed anti-piracy hasps some of which have been removed leaving holes in the door (Steering Gear room entrance/ Machinery room work area escape). 74 SOLAS (97) II-2/30.2 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 January 2018
Resolution: Received class report stating that fire door have been repaired.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 9 January 2018 Resolved
1410-Propulsion Main Eng-Provision shall be made to facilitate cleaning, inspection and maintenance of main propulsion and aux machinery including boilers and pressure vessels. The #1 f/o pump/injector supply manifold on the main diesel eng is leaking f/o at the connection to the manifold. 74 SOLAS (04) II-1/26.7 10c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 January 2018
Resolution: Connection was isolated, removed and o-ring replaced, done while inspectors where on board.
Engineering › Fuel Oil Service System › Filter
Issued 9 January 2018 Resolved
1430-Aux Engines-Provision shall be made to facilitate cleaning, inspection and maintenance of main propulsion and aux machinery including boilers and pressure vessels. The #1 SSDG (in stand by mode) is leaking f/o at the fuel oil filter. 74 SOLAS (04) II-1/26.7 10c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 January 2018
Resolution: Crew replaced the wasted filter and tightened all connections to stop the leak. Corrected while inspectors where on board the vessel.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 9 January 2018 Resolved
2045-Operation Other-Ballast- This part applies to non recreational vessels, U.S. and foreign that are equipped with ballast tanks and operate in the waters of the United States, except as expressly provided in 151.2015 and 151.2020 of this part. The 200NM extension given to the vessel under 33 CFR 151.2025 expired on Jan. 1, 2018, the vessel cannot produce a new letter and does not have an approved ballast water treatment system on board. Vessel cannot discharge ballast into U.S. Waters IAW 33 CFR 151.2025 unless they discharge to a facility or another vessel. If a new extension is not provided to vessel, the vessel must submit a plan to USCG IAW 151.2025 stating how they will manage ballast water w/ NOA as well as the Ballast Water Reporting Form to NBIC. 33 CFR 151.2010 40c
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 September 2023
Resolution: Open deficiencies on this decommissioned and scrapped vessel were administratively closed based on the objective evidence provided in Bureau Veritas’ email dated August 16, 2023. The email has been uploaded into the vessel’s documents.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 20 November 2017 Resolved
0615-Rescue Boat- Rapid recovery of the rescue boat shall be possible when loaded with its full complement of persons and equipment. During a test of the rescue boat launching appliances, rescue boat brake failed and dropped boat to water. At which time the electric controls used in recovery failed. All items repaired and tested sat prior to departure. 74 SOLAS (97)III/16.4
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 November 2017
Resolution: Vessels crew repaired the controller with new parts and replaced bolt that had slipped free on the brake mechanism. 10 C repaired prior to PSCO departure.
Deck/Cargo › Vapor Control Systems › Backflow Prevention
Issued 27 September 2017 Resolved
1138 - Liquified gasses in bulk - Airlock doors should be self closing and without any hold back arrangements. Vessels exterior airlock door closure was not able to self close without pushing in shut. 74 Solas (14) VII/ 13.1 IGC 3.6.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 October 2017
Resolved 28 September 2017
Resolution: Vessel replaced door closure in kind with a new one.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 11 May 2017 Resolved
Currently, there is an exhaust leak on the Inert Gas Generator. The exhaust leak caused the PSCC's and accompanying cre to experience burning eyes and to smell exhaust. PSCO's had alarms sounding on their portable 4-gas detection meters.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2017
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 15 September 2016 Resolved
1581-Rudder angle indicator- within 12 hours before departure ships steering gear shall be checked and test by the ships crew. The test procedures shall include operational test of the remote steering gear control systems. PSCO observed port bridge wing rudder angle indicator not working. 2014 SOLAS V Reg 26.1.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 11 October 2016
Resolution: During deficiency check and PII exam, received class report attesting to rudder angle indicator operating properly. PSCE visually observed it's operation during exam.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 September 2016 Resolved
1730-Oily water separating equipment-referred to in para 1 of this reg shal be of a design approved by the admin in considering the design of such equipment, the admin shall have regard to the specification recommend by the organization. PSCO observed plastic hose connection below oil content meter that doesn't appear to be original equipment. MARPOL Annex 1.14.6
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 September 2016
Resolved 11 October 2016
Resolution: During deficiency check and PII exam PSC team received class report attesting to repairs and PSCO visually observed plastic hose was replaced by metal pipe.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 9 June 2016 Resolved
1138 - Liquefied Gases in Bulk - Gas detection equipment should be so designed that it may readily be tested. Testing and calibration shall be carried out at regular intervals. Vessel's crew could not produce a "Flow Fault" alarm during examination of fixed gas detection system. Crew also did not have a calibration interval schedule. GAS CARRIER CODE A83 13.6.6
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2016
Resolution: Received class report, tested satisfactory. Flow fault alarm to be added to ships prodecures to be tested monthly.
Deck/Cargo › Cargo Condition › Bulk Liquefied Gas
Issued 9 June 2016 Resolved
1138 - Liquified Gases in Bulk - Electrical installation should be such to minimize the risk of fire and explosion from flammable products. PSCO discovered wiring on deck in various locations installed incorrectly and which could be potentially dangerous. GAS CARRIER CODE 1983 10.1.2
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2016
Resolution: Received survey report, wiring on deck was found to be reinstalled correctly.
Lifesaving › Inflatable Liferafts › Float Free
Issued 9 June 2016 Resolved
0620 - Inflatable Liferafts - Liferaft painter system shall provide connection between ship and liferaft. Liferaft painters on liferafts were not connected to the ship after drydock. 74 SOLAS 97 III/38.6.1
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 9 June 2016
Resolution: Rectified by ship crew on the spot.
Electrical › Electric Supply System (service) › Cable
Issued 9 June 2016 Resolved
1499 - Other (Prop & Aux Machinery) - Electrical apparatus shall be installed as not to cause injury when handled. Dead end wires found in engine room. 74 SOLAS 97 II-1/45.1.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 June 2016
Resolution: Received survey report, dead end wires were found to have been removed.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 9 June 2016 Resolved
0799 - Other (Fire Fighting Equipment) - All fire extinguishers shall be of an approved type and design. Extinguishers in engine room are mounted to bulkhead in an unapproved design. 74 SOLAS 97 II-2/6.1
Action required: 705 - Other - as specified
Resolved 10 June 2016
Resolution: Received survey report, extinguishers were found to be remounted to engine room bulkheads by surveyor.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 9 June 2016 Resolved
1420 - Cleanliness of Engine Room - The machinery shall be so installed and protected as to reduce to a minimum any dangers to persons on board. Soot on the main engine exhaust piping after turbo indicates a leak and potential for carbon monoxide in the space. 74 SOLAS 97 II-1/26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 June 2016
Resolved 10 June 2016
Resolution: Received survey report, gasket of the exhaust piping after the main engine turbo was replaced.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 13 January 2016 Resolved
0330 - Sanitary Facilities - Sanitary facilities must be provided for all ships crew on vessels over 500 GT. Water closets shall be provided with ample flush of water, available at all times and independently controlled. PSCO's observed two toilets not able to be independently controlled or able to flush. - ILO 147
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 January 2016
Resolution: Cleared during exam, Vessel was able to fix and show USCG that toilets operated correctly prior to departing vessel.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 January 2016 Resolved
0730 - Appliances (general equipment) - Stairways which penetrate only a single deck shall be protected by A60 self closing doors. PSCO's observed the machinery room entry door with derating damage. - 74 SOLAS (1997) II-2/9.2.3.4
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 February 2016
Resolution: RECEIVED RECEIPT FOR A CLASS FIRE DOORS AND CLASS REPORT ATTESTING TO PROPER INSTALLATION 14FEB16
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 January 2016 Resolved
0730 - Appliances (general equipment) - The construction of fire doors in "A" class divisions shall provide resistance to fire, as well as passage of smoke and flame equivalent. PSCO's observed derating damage to the fire door at the sanitary cleaning locker. - 74 SOLAS (1997) II-2 4.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 February 2016
Resolution: RECEIVED RECEIPT FOR A CLASS FIRE DOORS AND CLASS REPORT ATTESTING TO PROPER INSTALLATION OF DOORS 14FEB16
Communications › Alarms/Indicators › Propeller Pitch Position Indicator
Issued 13 January 2016 Resolved
1510 - Navigation equipment - The equipment and condition of the ship shall be maintained to conform with present regulations and conditions of survey. PSCO's observed the Pitch repeater on the CPP for bow thruster is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 February 2016
Resolution: received class report and survey attesting to repair, testing of system and proper operation of CPP 16feb16

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.