MAURY USCG vessel records Sign in
← All vessels

GAS KAIZEN

GAS KAIZEN is a 1991 tank ship. The Coast Guard has recorded 6 inspections since 2001, most recently in June 2008, along with 9 deficiencies and 1 operational control.

Records from 2001 to 2008. Most recent: inspection, 26 June 2008.

Built
1991
Last inspected
26 June 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8818817 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
406237
Flag
DENMARK
—
Maury page id
psix-406237

Inspections, by type

…with no type recorded1
Years with a record 3 calendar years (2001–2008)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7141 - Displacement, Ton
4380 - Dead Weight, Ton
1407 - Convention (Subpart B), Net Ton
4691 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 6

26 June 2008 COC-GAS Renew · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3233653
25 November 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1953882
19 March 2003 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1756997
19 March 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1759599
27 June 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 291127
27 June 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1073033

Deficiency record · 9

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 26 June 2008 Resolved
Vessels Vacuum alarm for the #1 Cargo Tank was found inoperable.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 July 2008
Resolved 27 June 2008
Resolution: Received BV Class report attesting to the repair and proper operation of the Vacuum Alarm on the # 1 Cargo Tank.
Deck/Cargo › Holds/Tanks
Issued 19 March 2003 Resolved
PROVIDE TECHNICIANS REPORT ATTESTING TO THE PROPER OPERATION, CALIBRATION, AND TESTING OF ALL ALARMS OF THE GAS DETECTION SYSTEM. IGC 13.6 LEGACY COMPONENT DESC: Fixed Gas Detection
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 19 March 2003 Resolved
PROVE PROPER OPERATION OF QUICK CLOSING VALVE ON FORWARD STARBOARD MANIFOLD HEADER. IGC 5.6.4 LEGACY COMPONENT DESC: Closure Devices
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2003
Electrical › Lighting (service)
Issued 19 March 2003 Resolved
PROVIDE EXPLOSION PROOF LIGHTING FIXTURE IN CARGO MOTOR ROOM . IGC 10.2.1 LEGACY COMPONENT DESC: Lighting Fixture
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2003
Construction/Loadline › Structures
Issued 19 March 2003 Resolved
PROVE PROPER OPERATION OF AIRLOCK SELF-CLOSING DOORS. IGS 3.6.2. LEGACY COMPONENT DESC: End Bulkhead
Condition: Unknown
Due 19 April 2003
Resolved 22 November 2003
Documentation › Safety/Response Plans/Programs
Issued 19 March 2003 Resolved
PROVIDE UPDATED FIRE PLAN TO INCLUDE FIRE CLASS DIVISIONS/BOUNDARIES. SOLAS 97 consol. II-2/20 LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Due 19 April 2003
Resolved 22 November 2003
Documentation › Manuals/Policy Documentation
Issued 19 March 2003 Resolved
PROVIDE PROCEDURES APPROVED BY CLASS AND SPECIFIED IN SHIPS OPERATING MANUAL TO THE CHANGING OF THE SET PRESSURES OF THE SAFETY RELIEF VALVES. IGC 8.2.7
Due 19 April 2003
Resolved 22 November 2003
Deck/Cargo › Cargo Stowage › General
Issued 19 March 2003 Resolved
PRIOR TO THE CARRIAGE OF PROPLYENE OXIDE OR ETHYLENE OXIDE, PROVE VESSEL IS IN COMPLIANCE WITH SUBCHAPTER "O" ENDORSEMENT IN REGARDS TO SPECIAL RESTRICITIONS, TO THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 26 June 2008
Documentation
Issued 27 June 2001 Resolved
Provide current editions of 46 CFR Parts 35, 150, 153 and 154._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 June 2001
Resolved 2 July 2001

Ownership record