Records from 1996 to 2006. Most recent: inspection, 23 June 2006.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 19 June 2006
Resolved
Replace missing Valve Handles ST-8 and ST-12 located on valves in cargo pumproom.
Action required: 705 - Other - as specified
Due 19 June 2006
Resolved 23 June 2006
Resolution: Handles replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 19 June 2006
Resolved
Renew/ repack all valves leaking from the valve stem in cargo pump room to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 July 2006
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Deck/Cargo › Ballast › Pumps
Issued 19 June 2006
Resolved
Repalce missing ballast temperature sensor and prove proper operation of ballast pump bearing temperature indicator to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 June 2006
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 June 2006
Resolved
Renew the three wasted ladders located in pump room to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 July 2006
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 19 June 2006
No resolution recorded
Repair leak of seal on #3 cargo oil turbine to provide gas tight barrier between engine room and cargo pump room.
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 19 June 2006
No resolution recorded
Internal transfer pipe for bunker line has soft patch located adjacent to starboard entrance to pumproom on main deck. Make permanent repairs to bunker line to the satisfaction of class.
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Construction/Loadline › Structures › Manhole
Issued 19 June 2006
Resolved
Renew/ replace the detached hand wheel for the steering room entrance to provide proper watertight integrity, that is located on stern to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 June 2006
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 19 June 2006
Resolved
Replace all broken light bulbs located in emergency escapes located in engine control room and from lower engine room flat to steering gear room.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2006
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 June 2006
No resolution recorded
Provide the calabration kit for the Oil Content Meter to properly calibrate oil content meter per manufacturers manual.
Action required: 705 - Other - as specified
Due 19 July 2006 — due date passed with no resolution recorded
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 19 June 2006
No resolution recorded
Make proper repairs to the Inert Gas System piping where holed at T after the isolation valve. Repairs to be made to the satisfaction of the classification society.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 19 June 2006
No resolution recorded
Renew as original hatch cover handles as needed on the cargo deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2006 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 19 June 2006
No resolution recorded
Renew as original cargo tank sounding attachments as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2006 — due date passed with no resolution recorded
Deck/Cargo › Crude Oil Washing Systems › Piping
Issued 19 June 2006
No resolution recorded
Repair leak on COW line serving 5 center prior to its use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Deck/Cargo › Inert Gas System › Venting System
Issued 19 June 2006
Resolved
Renew pressure/vacuum gauge indicator on the liquid filled pressure/vacuum breaker.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 19 June 2006
No resolution recorded
Renew cargo piping supports as needed. See 4th and 5th supports as counted from the house front.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Engineering › Feedwater/Condensate Water System › Piping
Issued 19 June 2006
No resolution recorded
Cargo Oil Pump Condensor line has pinhole leak located forward of COP pump in bottom engine room flat. Permanently repair pipe to satisfaction of classification society.
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Engineering › Lubricating Oil Service System › Purifier
Issued 19 June 2006
No resolution recorded
#2 lube oil purifier not servicable due to missing parts that have been ordered but not recieved. Prove proper operation of # 2 lube oil purifier to the satisfaction of class.
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 19 June 2006
No resolution recorded
Soft patch located on seawater supply for refrigeration pump located adjacent to port seawater strainer after isolation valve. Make permanent repair to piping to satisfaction of class.
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Fire Fighting › Portable Foam Applicators › General
Issued 19 June 2006
Resolved
Restore foam nozzles as needed.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2006
Resolution: Missing Foam Nozzels found and placed on station.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 19 June 2006
Resolved
Make repairs to hydraulic leak at the pipe run c/l aft of the cargo manifold.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Fire Fighting › Portable Foam Applicators › General
Issued 19 June 2006
Resolved
Make repairs to leaking foam pipe dresser coupling throughout the cargo deck as needed.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 19 June 2006
Resolved
Renew mast riser support cables. Swedges are missing and the thimble is open.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 19 June 2006
No resolution recorded
Make repairs to #2 center cow line where holed prior to cargo operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 June 2006
No resolution recorded
Restore as original to vapor tight and electrical bonded electrical conduit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 19 June 2006
Resolved
Clean and make available for inspection the cargo pump room.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2006
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 19 June 2006
Resolved
Noted lack of effective and systematic implementation of ISM and recommend an external audit be conducted by flag administration or Recognized Organization.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2006
Electrical › Electrical Distribution System (service) › Conductor
Issued 19 June 2006
Resolved
Remove moldy insulation from refrigeration lines and provide means of protecting 220v and 440v electrical junction boxes from condensate dripping onto them running from the refrigeration lines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2006
Resolution: Recieved Class Report
Deck/Cargo › Inert Gas System › Venting System
Issued 19 June 2006
Resolved
Make repairs to leak in inert gas system in the vicinity of pipe support number nine as counted from forward.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 June 2006
Resolved
Renew / Repair wasted and holed deck grating located between pump room fans on main deck to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 July 2006
Resolved 23 June 2006
Resolution: New Grating Placed on deck.
Documentation › Certificates/Documents › Annex VI Statement of Voluntary Compliance
Issued 19 June 2006
Resolved
Vessel did not submit a ballast water report as required. Submit ballast water report.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2006
Resolution: Vessel submitted Ballast Water Report to Agent for transmittal to the NBIC and copy provided to Coast Guard Inspector.
Engineering › Steam System (auxiliary) › Piping
Issued 19 June 2006
Resolved
Make repair to steam leak in the vicinity of the mast riser.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 19 June 2006
Resolved
Renew electrical junction box on emergency generator vent where wasted and exposing the wiring for the blower fan to the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 June 2006
Resolution: New junction box installed.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 19 June 2006
Resolved
Prove proper operation of Echo Depth sounder to the satisfaction of Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2006
Resolution: Recieved Class Report
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 19 June 2006
No resolution recorded
Renew exhaust pipe for emergency generator where holed. Location of hole is adjacent to vent for emergency generator room to the satisfaction of class prior to next port.
Action required: 705 - Other - as specified
Engineering › Steam System (auxiliary) › Piping
Issued 19 June 2006
Resolved
Renew and make operational all leaking steam valves located at the Engine Room deck 2. Portside adjacent to boiler.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 19 June 2006
Resolved
Restore sludge piping and pumps to original condition as provided for in class approved drawings and remove all extra valves and fittings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Engineering › Diesel Engine (auxiliary) › Camshaft
Issued 19 June 2006
No resolution recorded
Renew and make operatonal alarm panel for #2 and #3 main diesel generators as original. Currently alarms are indicated due to bad sensors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Portable Fuel System
Issued 19 June 2006
No resolution recorded
Renew or replace all guages in purifier room that are unreadable of inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2006 — due date passed with no resolution recorded
Engineering › Steam System (auxiliary) › Piping
Issued 19 June 2006
Resolved
Permanently repair soft patch located on steam line located aft of boiler on Engine Room deck number two.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed veified by Coast Guard Marine Inspector.
Engineering › Steam System (auxiliary) › Piping
Issued 19 June 2006
Resolved
Make repairs to steam leaks on pipe and pipe flange in the vicinity of 2C p/v vent.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed, sighted by Coast Guard Marine Inspectorl
Engineering › Steam System (auxiliary) › Piping
Issued 19 June 2006
No resolution recorded
Renew steam line pipe number 10 pipe support as counted from forward.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Fire Fighting › Structural - Main Vertical Zones › General
Issued 19 June 2006
Resolved
Update fire control plan to include means of access from main stairwell into the galley.
Action required: 705 - Other - as specified
Resolved 30 June 2006
Resolution: Recieved Class Report
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 19 June 2006
No resolution recorded
Renew/replace wasted ladders from main deck to foam monitor station number five.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2006 — due date passed with no resolution recorded
Deck/Cargo › Inert Gas System › Venting System
Issued 19 June 2006
No resolution recorded
Renew corroded mast riser cover plates.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Lifesaving › Lifeboat › Propulsion Starting System
Issued 19 June 2006
Resolved
Make repairs to the starboard lifeboat starting system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 August 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 19 June 2006
Resolved
Make repairs and prove operation of the inert gas high temperature and high pressure alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 19 June 2006
Resolved
Make repairs and recalibrate the cargo pump room gas detection system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed, sighted by Coast Guard Marine Inspector.
Fire Fighting › Fire Main › Condition
Issued 19 June 2006
Resolved
Restore fire main. Black oil was discharged during drill from navigation and captains deck fire hydrant.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed, sighted by Coast Guard Marine Inspector.
Operations/Management › Drills/Instruction › Fire
Issued 19 June 2006
Resolved
Complete satisfactory fire drill.
Action required: 705 - Other - as specified
Resolved 30 June 2006
Fire Fighting › Fire Main › Material
Issued 19 June 2006
Resolved
Make repairs to the ruptured fire main near the deck water seal.
Action required: 705 - Other - as specified
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 19 June 2006
Resolved
Make repairs and prove operation of the deck water seal low water alarm.
Action required: 705 - Other - as specified
Resolved 23 June 2006
Resolution: Recieved Class report attesting to permanent repair completed.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 19 June 2006
No resolution recorded
Make repairs to the ODME valve position indicator microswitch.
Action required: 705 - Other - as specified
Due 21 August 2006 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 19 June 2006
No resolution recorded
Repair nonoperational dry provisions store and dairy refrigerations units and make free of pests. Pest specimen was collected by the Department of Agriculture and shipped to Puerto Rico for analysis. The Dry provisions store must remain sealed until cleared by the DOA. The dairy refrigeration units have been cleared by DOA.
Action required: 705 - Other - as specified
Electrical › Lighting (service) › Lighting Fixture
Issued 17 June 2005
Resolved
Replace light cover (cracked) portside just at the bottom of the first ladder level, to the satisfaction of class, flag,or uscg inspector.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 June 2005
Resolution: CLASS SURVEY CONDUCTED AND REPAIRS MADE ON JUNE 17th, 2005. 13 DEC 05 CLASS SURVEY REPORT RECIEVED. DISCREPENCY CLEARED.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 June 2005
Resolved
In the cargo pump room lower level, install the cover for the #2 indicator on the telephone, the wires are exposed. Satisfy to the satisfaction of Class, Flag, or the USCG.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 June 2005
Resolution: 17 JUNE 05 CLASS SURVEY CONDUCTED AND REPAIRS MADE. 13 DEC 05 CLASS SURVEY REPORT RECEIVED. CLASS REPORT IS SUFFICIENT TO CLEAR DEFICIENCY.
Deck/Cargo › Inert Gas System
Issued 3 January 2004
Resolved
Instrumentation of continuously reading the oxygen content for the inert gas system is inoperable. Crew must take oxygen readings every hour and record the same. Prior to the vessel returning from a foreign voyage the vessel must provide proof from Class, that the content meter is working properly. LEGACY COMPONENT DESC: Oxygen Content Meter
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 February 2004
Personnel › Certificates/Documents/Licenses › License, Second Mate
Issued 3 January 2004
Resolved
Second officer missing flag state STCW endorsement. Vessel may not depart from the Port of New York until the USCG receives proof that Liberia has accepted the officer's Lithuanian license or has a national license that matches that which is on his Liberian endorsement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2004
Resolution: Received a copy of his Latvia license, which matches his Liberian endorsement.
Fire Fighting › Fire Hydrants
Issued 3 January 2004
Resolved
Fireplug #18 at frame #28 in lower level of engine room is not easily seen. Crew to paint the area around the fireplug so it may be easily seen. LEGACY COMPONENT DESC: Location/Position
Action required: 705 - Other - as specified
Due 3 February 2004
Resolved 7 February 2004
Engineering › Generator (propulsion/auxiliary-electric)
Issued 3 January 2004
Resolved
Saltwater cooling line for the #2 generator has a hose clamp over a hole. Crew to make permanent and proper repairs to the satisfaction of the attending classification surveyor.
Action required: 705 - Other - as specified
Due 3 February 2004
Resolved 7 February 2004
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 3 January 2004
Resolved
The following portable fire extinguishers are to be installed in their proper brackets, engine room machine shop #31, and both the port and starboard lifeboats. To the satisfaction of the attending classification surveyor. LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 3 February 2004
Resolved 7 February 2004
Construction/Loadline › Structures
Issued 3 January 2004
Resolved
Watertight emergency escape hatch out of the steering space cannot be made watertight. Crew to make this hatch watertight and also easy to open. Demonstrate proper operation to the attending classification surveyor. LEGACY COMPONENT DESC: Scuttle
Action required: 705 - Other - as specified
Due 3 February 2004
Resolved 7 February 2004
Documentation › Safety/Response Plans/Programs
Issued 3 January 2004
Resolved
Provide a Marine Chemist report so a US Coast Guard inspector may enter the vessel's cargo pump room to complete a inspection.
Action required: 705 - Other - as specified
Due 17 January 2004
Resolved 9 February 2004
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 3 January 2004
Resolved
Door out of the hospital cannot be opened.
Action required: 705 - Other - as specified
Due 3 February 2004
Resolved 3 January 2004
Resolution: Crew repaired the door.
Accommodation/Occupational Safety › Occupational Safety
Issued 3 January 2004
Resolved
Door out of the accommodation passageway on the officer deck, starboard side leading aft cannot be opened.
Due 3 February 2004
Resolved 3 January 2004
Resolution: Crew repaired the door.
Lifesaving › Lifeboat
Issued 3 January 2004
Resolved
Water spray for the port lifeboat in operational. Demonstrate proper operation of the water spray to the attending classification surveyor. LEGACY COMPONENT DESC: Fire Protection (water spray system)
Action required: 705 - Other - as specified
Due 3 February 2004
Resolved 7 February 2004
Deck/Cargo
Issued 3 September 2001
Resolved
O2 ANLYSER FOR IGS SYSTEM REMOVED FOR REPAIR. PRIOR TO RETURN U.S. PROVIDE CLASS REPORT THAT VERIFYS IGS SYSTEM MEETS SOLAS 74.
Condition: Unknown
Due 5 September 2001
Resolved 21 May 2002
Resolution: Deficiency corrected after received Class Report via fax form vessel agent in Puerto Rico, [name withheld] Colon. Deficiency corrected to Class satisfaction.
Deck/Cargo
Issued 14 October 1997
Resolved
Install and prove proper operation of cargo tank overfill alarms (98%) as stated in 33CFR155.480 and 46CFR39.20-7 prior to loading cargo in U.S. waters.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Documentation
Issued 24 July 1997
Resolved
LOADLINE RUSTED, NOT IN CONTRASTING COLOR._x001C_ ILLC CH. I REG 8.
Condition: Unknown
Due 4 August 1997
Resolved 4 August 1997
Engineering
Issued 2 November 1996
Resolved
REPAIR BOILER FOR INERT GAS SYSTEM TO THE SATISFATION OF CLASS AND ATTENDING MARINE INSPECTOR PRIOR TO OFF-LOADING CARGO.
Condition: Unknown
Due 3 November 1996
Resolved 12 November 1996