MAURY USCG vessel records
← All vessels

NICHIYUH MARU

NICHIYUH MARU is a 1989 tank ship. The Coast Guard has recorded 1 inspection in 2016, along with 1 deficiency — 1 with no resolution recorded —.

Records in 2016. Most recent: inspection, 20 January 2016.

Built
1989
Last inspected
20 January 2016
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 January 2016
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2016)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8718469
406522
Flag
JAPAN
Maury page id
psix-406522

Documentation record

Tonnage as PSIX records it13430 - Convention (Subpart B), Net Ton
50741 - Dead Weight, Metric Ton
67108 - Displacement, Metric Ton
44769 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

20 January 2016 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5800221

Deficiency record · 1

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 January 2016 No resolution recorded
IOPP certificate indicates oil water separator approved resolution A 393(x). Placard on OWS indicates MEPC.107(49) while IOPP certificate indicates oil content meter approved resolution A.393(x). Oil content meter is MEPC.107(49).
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 February 2016 — due date passed with no resolution recorded

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.