MAURY USCG vessel records Sign in
← All vessels

DANICA VIOLET

DANICA VIOLET is a 1985 freight ship. The Coast Guard has recorded 17 inspections since 1998, most recently in November 2025, along with 15 deficiencies — 2 with no resolution recorded — and 3 operational controls.

Records from 1998 to 2025. Most recent: inspection, 8 November 2025.

Built
1985
Last inspected
8 November 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8503967 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
406541
Flag
DENMARK
—
Maury page id
psix-406541

Inspections, by type

…with no type recorded7
…past their stated due date1
Years with a record 10 calendar years (1998–2025)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1088 - Regulatory (Subpart C or D), Gross Ton
584 - Regulatory (Subpart C or D), Net Ton
1788 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

8 November 2025 PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8262627
8 November 2025 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8265091
4 November 2024 PSC A
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8026935
11 September 2021 PSC A
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7307615
17 August 2018 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6512611
13 August 2018 Deficiency Check · ISPS II Exam · PI Safety Exam · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6506854
7 August 2018 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6503638
6 March 2009 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3423628
29 October 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3353700
27 September 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2502464
14 September 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2492045
26 August 2005 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2475294
20 May 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1618418
13 March 2002 Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1493539
12 November 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 434638
22 November 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 422860
25 April 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 415247

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 November 2025 Resolved
Two means of escape shall be provided from each machinery space of Category A. In particular, one of the following provisions shall be complied with: In the lower part of the space, a steel door which provides access to a safe escape route from the lowest part of the space to the open deck. PSCO observed the emergency escape hatch in the engine room that was missing one of its hinges due to rusting.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 November 2025
Resolved 9 November 2025
Resolution: Vessel made repairs on the escape hatch, replacing the hinge that had rusted away. Vessel received Class approval for the repairs and provided Class correspondence to Sector North Carolina.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 November 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed accumulation of standing oil in the bilge under and around the main engine.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 November 2025
Resolved 9 November 2025
Resolution: Vessel crew drained the vessels bilge and removed oil. PSCO observed the bilge being emptied and cleaned while on board the vessel.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 8 November 2025 No resolution recorded
The Safety Management System shall be maintained in accordance with the provisions of the International Safety Management Code. As noted in deficiencies 1 and 2, there is objective evidence the ship is not being maintained as required according to the ship's Safety Management System. External ISM Audit is recommended with a focus on Fire Safety and Engine Room Maintenence.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 November 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 November 2025 Resolved
Electrical installations shall be such that: The safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed improperly secured wires from a ventilation fan installation in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 November 2025
Resolved 8 November 2025
Resolution: PSCO observed the crew securing the wires hanging from the ventilation fan mount in the engine room.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 November 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed a tie back on a Class A fire door located in the switchboard room.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 November 2025
Resolved 8 November 2025
Resolution: PSCO observed the tie back being removed from the Class A fire door in the switchboard room.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 November 2025 Resolved
Main and emergency switchboards shall be so arranged as to give easy access as may be needed to apparatus and equipment, without danger to personnel. PSCO observed vessel stores and provisions blocking access to the main switchboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 November 2025
Resolved 8 November 2025
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 11 September 2021 No resolution recorded
Testing for transfer piping had not been conducted required by 33CFR156.170(c)(4)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 August 2018 Resolved
The #2 cargo hatch has a hole, the vessel's crew will make temporary repairs; permanent repairs are to be made to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 August 2018
Resolution: Rec'd class report, condition of class issued.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 August 2018 Resolved
Vessel is required to have a Vessel General Permit (VGP). Obtain VGP for vessel.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 August 2018
Resolution: Rec'd class report, vessel had VGP on board but was unaware.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 13 August 2018 Resolved
The port embarkation light is not working; make repairs as necessary.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 August 2018
Resolution: Rec'd class report, light has been replaced.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 29 October 2008 Resolved
Vessel has excessive leaks from the fuel filters and injectors on the ships service generators. Vessel must make repairs to the satisfaction of the certificate issuing authority.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2008
Resolved 4 November 2008
Resolution: Received class report. The leakage at the filters has been rectified and new fuel pipe fitted in place and generators tried out.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 29 October 2008 Resolved
Vessel has excessive amounts of oil in the bilges creating a fire hazard. Vessel must take appropriate actions to discharge the oily waste from the bilges to the satisfaction of the certificate issuing authority
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2008
Resolved 4 November 2008
Resolution: Vessel pumped ashore 844 gallons of oily waste and receipt and record onboard.
Engineering › Fuel Oil Service System › Valve, Control
Issued 29 October 2008 Resolved
Vessels emergency shut-off for the daily service tank for the emergency generator is leaking from the flange creating a fire hazard. Vessel must make proper repairs to the satisfaction of the certificate issuing authority.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2008
Resolved 4 November 2008
Resolution: The gasket for the flange faces has been renewed.
Engineering › Fuel Oil Storage/Transfer System
Issued 13 March 2002 Resolved
Fuel oil vent flame screen wasted. LEGACY COMPONENT DESC: Vent Pipe
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 23 May 2002
Resolution: REPLACED BAD FLAME SCREENS FOR THE FUEL OIL VENTS.
Lifesaving
Issued 25 April 1998 Resolved
Emergency instructions for fire drill not followed; missing portable VHFs for communications. Correct prior to next U.S. portcall after sailing foreign.
Condition: Unknown
Due 22 November 1998
Resolved 22 November 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.