Records from 2018 to 2025. Most recent: inspection, 8 November 2025.
Inspection history · 7
8 November 2025
PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8262627
8 November 2025
Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8265091
4 November 2024
PSC A
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8026935
11 September 2021
PSC A
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7307615
17 August 2018
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6512611
13 August 2018
Deficiency Check · ISPS II Exam · PI Safety Exam · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6506854
7 August 2018
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6503638
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 November 2025
Resolved
Two means of escape shall be provided from each machinery space of Category A. In particular, one of the following provisions shall be complied with: In the lower part of the space, a steel door which provides access to a safe escape route from the lowest part of the space to the open deck. PSCO observed the emergency escape hatch in the engine room that was missing one of its hinges due to rusting.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 November 2025
Resolved 9 November 2025
Resolution: Vessel made repairs on the escape hatch, replacing the hinge that had rusted away. Vessel received Class approval for the repairs and provided Class correspondence to Sector North Carolina.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 November 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed accumulation of standing oil in the bilge under and around the main engine.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 November 2025
Resolved 9 November 2025
Resolution: Vessel crew drained the vessels bilge and removed oil. PSCO observed the bilge being emptied and cleaned while on board the vessel.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 8 November 2025
No resolution recorded
The Safety Management System shall be maintained in accordance with the provisions of the International Safety Management Code. As noted in deficiencies 1 and 2, there is objective evidence the ship is not being maintained as required according to the ship's Safety Management System. External ISM Audit is recommended with a focus on Fire Safety and Engine Room Maintenence.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 November 2025 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 November 2025
Resolved
Electrical installations shall be such that: The safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed improperly secured wires from a ventilation fan installation in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 November 2025
Resolved 8 November 2025
Resolution: PSCO observed the crew securing the wires hanging from the ventilation fan mount in the engine room.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 November 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed a tie back on a Class A fire door located in the switchboard room.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 November 2025
Resolved 8 November 2025
Resolution: PSCO observed the tie back being removed from the Class A fire door in the switchboard room.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 November 2025
Resolved
Main and emergency switchboards shall be so arranged as to give easy access as may be needed to apparatus and equipment, without danger to personnel. PSCO observed vessel stores and provisions blocking access to the main switchboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 November 2025
Resolved 8 November 2025
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 11 September 2021
No resolution recorded
Testing for transfer piping had not been conducted required by 33CFR156.170(c)(4)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 August 2018
Resolved
The #2 cargo hatch has a hole, the vessel's crew will make temporary repairs; permanent repairs are to be made to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 August 2018
Resolution: Rec'd class report, condition of class issued.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 August 2018
Resolved
Vessel is required to have a Vessel General Permit (VGP). Obtain VGP for vessel.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 August 2018
Resolution: Rec'd class report, vessel had VGP on board but was unaware.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 13 August 2018
Resolved
The port embarkation light is not working; make repairs as necessary.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 August 2018
Resolution: Rec'd class report, light has been replaced.