MAURY USCG vessel records Sign in
← All vessels

PHILIPOS

PHILIPOS is a 1993 freight ship. The Coast Guard has recorded 55 inspections since 1994, most recently in December 2008, along with 57 deficiencies and 11 operational controls.

Records from 1994 to 2008. Most recent: inspection, 11 December 2008.

Built
1993
Last inspected
11 December 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9055931 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
406802
Flag
MALTA
—
Maury page id
psix-406802

Inspections, by type

…with no type recorded38
Years with a record 13 calendar years (1994–2008)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it13713 - Displacement, Ton
9457 - Dead Weight, Ton
3570 - Convention (Subpart B), Net Ton
7662 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 55

11 December 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3378299
9 December 2008 Ballast Water Examination · ISPS I Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3374353
9 December 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3377070
4 December 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3374015
4 February 2005 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2283729
10 January 2005 PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2271911
3 December 2004 MARPOL Annex V Examination · ILO-147 Exam · MARPOL Annex I Examination · STCW 95 Exam · PII Safety Exam · ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2249518
2 December 2004 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2254957
25 November 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2247871
8 July 2004 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2124607
7 July 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2125314
5 July 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2122586
10 June 2004 Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2094882
4 June 2004 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2093667
9 March 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2023833
13 January 2004 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1989809
22 December 2003 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1968557
15 December 2003 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1964722
12 December 2003 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1964676
30 October 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1939300
6 June 2003 Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1814294
2 June 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1808519
29 November 2002 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1712492
14 November 2002 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1705653
15 October 2002 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1690315
16 August 2002 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1662463
2 August 2002 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1655782
17 April 2002 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1605934
24 January 2002 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1481150
6 November 2001 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 295345
27 September 2001 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 294159
25 September 2001 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 294069
26 September 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 282587
20 July 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 280214
16 March 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 275753
18 August 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 431720
6 May 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 415683
14 September 1997 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 407913
16 September 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 395408
27 April 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 390449
21 March 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 389014
2 October 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 383331
29 August 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 381948
25 June 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 379837
23 March 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 376454
10 October 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 371202
7 October 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 508071
2 September 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 370166
31 August 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 701620
29 August 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 525896
29 August 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1177244
29 August 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1177848
28 July 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 368931
16 June 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 701621
26 May 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 367314

Deficiency record · 57

Operations/Management › Drills/Instruction › Fire
Issued 9 December 2008 Resolved
Perform fire drill IAW SMS. Improperly dressed firefighters, command was not effectively directing fire party. Additional training needed. Crew to perform a satisfactory fire drill to the satisfaction of the Coast Guard prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2008
Resolution: Corrected to the satisfaction of the USCG.
Lifesaving › Launching Appliances › Davit
Issued 9 December 2008 Resolved
Provide proper operation of port and starboard lifeboat davit and recovery appliance. Limit switch did not activate causing lifeboat to slam into davit arm. Ship to repair to the satisfaction of the Coast Guard, prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2008
Resolution: Corrected to the satisfaction of the USCG.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 3 December 2004 Resolved
Drainage scuppers in galley were blocked causing flooding. Must be cleaned and clerared prior to next U.S. Port. (Dec 6, 2004)
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 6 December 2004
Resolved 10 January 2005
Resolution: Received class report from Germanischer Lloyd satisfying requirement.
Fire Fighting › Nozzles › Location
Issued 3 December 2004 Resolved
Nozzles and Spanner Wrenches missing from fire boxes. Advised to locate and replace all nozzles, hoses and spanner wrenches and place in fire boxes by next U.S. Port.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 6 December 2004
Resolved 10 January 2005
Resolution: Received class report from Germanischer Lloyd satisfying requirement.
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 3 December 2004 Resolved
No rubber matter in front of switchboard. Advised to install new matting within 30 days. (Jan 3, 2005)
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 10 January 2005
Resolution: Received class report from Germanischer Lloyd satisfying requirement.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 30 October 2003 Resolved
Hot water in Hospital not available. Provide class report attesting to repairs. LEGACY COMPONENT DESC: Hot and Cold Running Water
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 22 December 2003
Resolution: Received Class report by GL surveyor Debrowski attesting to hot water in hospital.
Navigation › Piloting/Steering
Issued 30 October 2003 Resolved
Steering loss of power alarm inoperable. Provide class report attesting to repairs.
Due 20 November 2003
Resolved 22 December 2003
Resolution: Received Class report by GL surveyor Debrowski attesting to operation of alarm for loss of power.
Electrical › Electric Generation Source (emergency)
Issued 30 October 2003 Resolved
Secondary means of starting inoperable. Provide class report attesting to repairs. LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 13 November 2003
Resolved 22 December 2003
Resolution: Received Class report by GL surveyor Debrowski attesting to generator starting operations.
Electrical › Lighting (service)
Issued 30 October 2003 Resolved
Repair/replace lighting fixtures including missing light (Portside Main Door), broken light globe (Washroom 628) and others damaged or missing. Provide class report attesting to repairs. LEGACY COMPONENT DESC: Lighting Branch Circuit
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 22 December 2003
Resolution: Received Class report by GL surveyor Debrowski attesting to repairs/replacement to lighting fixtures.
Lifesaving › Lifebuoys
Issued 30 October 2003 Resolved
Lifebuoys in various locations in poor condition. Provide class report attesting to repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 22 December 2003
Resolution: Received Class report by GL surveyor Debrowski attesting to replacement of lifebouys.
Engineering › Lubricating Oil Service System
Issued 30 October 2003 Resolved
Repair lube oil gauge in vicinity of lube oil pump STBD side. Repair leaks at fuel oil pumps. Provide class report attesting to repairs. LEGACY COMPONENT DESC: Gauge
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 22 December 2003
Resolution: Received Class report by GL surveyor Debrowski attesting repair of lube oil gauge and leaks on STBD side.
Fire Fighting › Ventilation Systems
Issued 30 October 2003 Resolved
Repair ventilation closures 10,11,12 and dogs to No.3 cargo hold hatch. LEGACY COMPONENT DESC: Duct Hatches
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 22 December 2003
Resolution: Received Class report by GL surveyor Debrowski attesting to repair of ventilation closures 10, 11, 12, and dogs to #3 cargo hold hatch.
Fire Fighting › Fixed Fire Detection System
Issued 30 October 2003 Resolved
Repair push button fire alarm box outside emergency generator room. (Box closure is frozen) Provide class report attesting to repairs.
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 22 December 2003
Resolution: Received Class report by GL surveyor Debrowski attesting to repair of fire alarm box outside emergency generator room.
Navigation
Issued 30 October 2003 Resolved
Echo depth sounder paper recorder in need of calibration. Provide class report attesting to repairs.
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 22 December 2003
Resolution: Received Class report by GL surveyor Debrowski attesting to calibration of echo depth sounder paper recorder.
Electrical
Issued 15 October 2002 Resolved
Rigged electrical outlet in engine. Remove receptacle and wiring to the satisfaction of the classification society.
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 14 November 2002
Resolution: Received class report attesting to repairs.
Electrical › Electric Supply System (service)
Issued 15 October 2002 Resolved
Electrical ground on 220V supply. Isolate and make repairs to 220V supply to the satisfaction of Class prior to departure from the port of Houston.
Action required: 705 - Other - as specified
Due 15 October 2002
Resolved 16 October 2002
Resolution: Received report from Class attesting to repairs. Vessel cleared to sail.
Engineering
Issued 15 October 2002 Resolved
Soft patches found on the main engine cooling water heat exchanger (sea water outlet) and on the sea water supply to the main engine air cooler. Make repairs to the satisfaction of Class no later than 15NOV02.
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 14 November 2002
Resolution: Received class report attesting to sat temp repairs. Condition of class issued for permanent repairs at next drydock.
Engineering
Issued 15 October 2002 Resolved
Vessel has unapproved installation of heavy fuel oil additive permanently installed to the heavy oil line. Have vessel's classification society address installation arrangement no later than 15NOV02.
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 14 November 2002
Resolution: Received class report attesting to approval of installation after modifications. Replaced rubber line with rigid pipe and installed a valve at the fuel filter cover plate.
Engineering › Sea-water System (primary cooling)
Issued 2 August 2002 Resolved
Main diesel engine overheats when vessel speed exceeds 9 knots (SOLAS 74 I/11): Perform maintenance on cooling system and test to satisfaction of Safety Construction Certificate issuing authority.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2002
Resolved 3 August 2002
Resolution: Rec''d Class (GL) rpt attesting to sat repairs.
System not recorded
Issued 6 November 2001 Resolved
REPAIR OR ADJUST AS NECESSARY FIRE DOORS TO ENGINE CONTROL ROOM AND ENTRANCES TO ENGINE ROOM.
Condition: Unknown
Due 7 December 2001
Resolved 24 January 2002
Resolution: CORRECTED
Lifesaving
Issued 25 September 2001 Resolved
ROPE WASTED ON PORT LIFE BOAT EMBARKATION SOLAS III 48.7
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Lifesaving
Issued 25 September 2001 Resolved
LIMIT SWITCH ON STBD. LIFE BOAT INOPERABLE SOLAS III 48.2.5
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Navigation
Issued 25 September 2001 Resolved
EXCESSIVE HYDRAULIC OIL ON DECK IN STEERING ROOM SOLAS III 48.7.
Condition: Unknown
Due 27 September 2001
Resolved 25 September 2001
Navigation
Issued 25 September 2001 Resolved
MISSING CHART 3981 OR 11361 FOR THE SOUTHWEST APPROACH 33 CFR 164.33 (a).(b).
Condition: Unknown
Due 27 September 2001
Resolved 25 September 2001
Lifesaving
Issued 25 September 2001 Resolved
THE INSTALLED AUDIBLE ALARM INOPERABLE FOR THE OILY WATER SEPARATOR MARPOL AX. 1/16.
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Electrical
Issued 25 September 2001 Resolved
MISSING LIGHT COVERS IN ENGINE ROOM ILO 147.
Condition: Unknown
Due 7 November 2001
Resolved 7 November 2001
Lifesaving
Issued 26 September 2000 Resolved
Excessive oil in bilge
Condition: Unknown
Due 26 September 2000
Resolved 28 September 2000
Engineering
Issued 26 September 2000 Resolved
Temporary repair to oil discharge on main engine
Condition: Unknown
Due 29 September 2000
Resolved 28 September 2000
Navigation
Issued 26 September 2000 Resolved
Echo depth sounder recorder inoperable.
Condition: Unknown
Due 26 September 2000
Resolved 28 September 2000
Electrical
Issued 16 March 2000 Resolved
Emergency generator needs a second mean of starting. Repair to the satisfaction of class.
Condition: Unknown
Due 21 July 2000
Resolved 21 July 2000
Fire Fighting
Issued 18 August 1999 Resolved
Class to attend vessel and attest to proper operation of emergency fire pump. Pump worked intermittantly; possible that there was a stuck check valve.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Engineering
Issued 18 August 1999 Resolved
Proper repairs to be made to condensate pipes above OWS in engine room.
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Lifesaving
Issued 18 August 1999 Resolved
Replace oil-soaked lagging found in coffer dam below diesel oil service tank. Access is through lower level engine room.
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Lifesaving
Issued 18 August 1999 Resolved
Provide instructions for on board maintenance of lifeboat equipment.
Condition: Unknown
Due 18 August 1999
Resolved 18 August 1999
Unknown
Issued 18 August 1999 Resolved
Install handle on door for access to passageway from the galley.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Fire Fighting
Issued 18 August 1999 Resolved
Remove holdbacks from fire screen doors.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Lifesaving
Issued 18 August 1999 Resolved
Prove that port and starboard lifeboat falls were renewed at 5 year interval.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Fire Fighting
Issued 18 August 1999 Resolved
Replace fire hose lower level, forward port-side.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Unknown
Issued 18 August 1999 Resolved
Class to attest to the sound condition of SSDG salt water piping.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Unknown
Issued 18 August 1999 Resolved
Class to attest to the piping modification found lower level engine room, aft on centerline where rubber hoses com from steering gear flat bilge water tank.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Lifesaving
Issued 18 August 1999 Resolved
Provide four rocket flares each for port and starboard lifeboats.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Construction/Loadline
Issued 18 August 1999 Resolved
Make permanent repairs to side rail stiffeners where the stiffeners meet maindeck combing in midships half-length.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Lifesaving
Issued 18 August 1999 Resolved
Class to attend vessel and make recommendation for repair to starboard lifeboat, aft port-side corner where it is holed and cracks propagate.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Lifesaving
Issued 18 August 1999 Resolved
Class to attend vessel and attest to the proper operation of starboard lifeboat limit switches.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Engineering
Issued 18 August 1999 Resolved
Class to attend vessel and attest to proper repairs made to main engine fuel oil return line.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Engineering
Issued 18 August 1999 Resolved
Class to attend vessel amd make recommendations to correct numerous lube oil leaks on main engine.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Engineering
Issued 18 August 1999 Resolved
Remove excess oil/fuel/water from main engine block and engine room bilges.
Condition: Unknown
Due 31 August 1999
Resolved 31 August 1999
Lifesaving
Issued 6 May 1998 Resolved
REPLACE 4 EXPIRED ROCKET PARACHUTTE FLARES ON BRIDGE.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Lifesaving
Issued 6 May 1998 Resolved
REPLACE RETROTAPE ON BOTH LIFEBOATS.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Navigation
Issued 21 March 1996 Resolved
letter of deviation for inop radar.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Electrical
Issued 29 August 1995 Resolved
Failure to provide secondary source of energy for operation of emergency generator in accordance with SOLAS Consolidated Edition 92 (SOLAS 74) Chapter 11-1 Part D Regulation 44-2.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Navigation
Issued 26 May 1994 Resolved
MISSING REQUIRED CHARTS OR EQUIVLALENT BA 899_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 May 1994
Resolved 31 May 1994
Navigation
Issued 26 May 1994 Resolved
COPY OF THE INLAND NAVIGATION RULES NOT ON BOARD AS REQUIRED BY THE COTP
Condition: Unknown
Due 27 May 1994
Resolved 31 May 1994
Navigation
Issued 26 May 1994 Resolved
MANEUVERING FACT SHEET MISSING WARNING STATEMENT
Condition: Unknown
Due 27 May 1994
Resolved 31 May 1994
Documentation
Issued 26 May 1994 Resolved
REQUIRED CERTIFICATE OF FINANCIAL RESPONSIBILITY NOT ON BOARD.
Condition: Unknown
Due 27 May 1994
Resolved 31 May 1994
Documentation
Issued 26 May 1994 Resolved
REQUIRED IOPP CERTIFICATE NOT ON BOARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 May 1994
Resolved 31 May 1994
Documentation
Issued 26 May 1994 Resolved
MISSING REQUIRED OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 27 May 1994
Resolved 31 May 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.