Built
1992
Last inspected
26 November 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9047491 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
407077
Flag
NORWAY
—
Maury page id
psix-407077

Inspections, by type

…with no type recorded32
Years with a record 19 calendar years (1994–2018)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it23197 - Convention (Subpart B), Gross Ton
12176 - Convention (Subpart B), Net Ton
28043 - Displacement, Ton
37221 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

WORK BARGE Industrial Vessel · MISLE 26536 · 25 April 2001 · activity 1559

Inspection history · 54

26 November 2018 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6586475
21 June 2016 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5914081
2 May 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5867693
16 February 2016 PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5815488
23 October 2015 NPV Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5749875
2 October 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4997643
22 June 2014 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4895527
15 June 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4889071
20 February 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4247635
14 February 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4244189
13 October 2010 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3869492
2 September 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3315827
25 July 2008 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3278685
12 June 2008 ISPS II Exam · PII Safety Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3234559
6 June 2006 ISPS II Exam · COC-CHEM Annual · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2672535
8 March 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2602064
1 March 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2594021
16 November 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2535640
15 November 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2538536
15 November 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2582293
23 May 2005 COC-CHEM Renew · ISPS III Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2366209
17 May 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2369702
15 October 2004 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2221863
15 July 2004 PII Safety Exam · ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2133557
21 March 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2029028
8 December 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1960715
23 May 2003 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1799517
16 September 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1677000
15 September 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1675761
6 September 2002 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1671929
4 September 2002 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1670467
3 September 2002 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1678145
1 December 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 295976
11 November 2001 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 443119
25 April 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1559
14 April 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 289045
7 March 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 275497
7 March 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1460383
13 October 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 12583
5 February 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 425257
5 February 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 799168
24 August 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 406983
24 August 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 784685
10 July 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 393250
9 July 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 393008
8 July 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1086542
22 September 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 382847
14 December 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 646214
7 December 1994 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1142259
1 December 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 500203
29 August 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 703959
7 August 1994 Deficiency Check · Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 867295
1 August 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 369024
1 August 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 869264

Deficiency record · 23

Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 24 October 2015 Resolved
Vessel experienced loss of propulsion while shifting berths. Chief engineeer replaced exhaust valve. Defeciency will be cleared once class report is received.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2015
Resolved 26 October 2015
Resolution: Received class report attesting to the repairs on the exhaust valve.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 February 2012 Resolved
Received report of inoperable secondary marine radar. (33CFR164.37(a))
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2012
Resolution: Received tech report of proper operation of S-band radar.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 17 October 2010 Resolved
1410 - Propulsion Main Engine - Bridge controls for engine speed and pitch control do not allow engine RPM to exceed 85 and pitch to exceed 60%. Vessel is to demonstrate proper operation of main engine governor and controllable pitch propeller from the bridge (remote) and engine room (local) controls to the satisfaction of class. 74SOLAS (2004 cons ed.) Reg 49.1
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2010
Resolution: Sector Delaware Bay received a report from class attesting to the proper operation of the governor and controllable pitch propeller from the bridge and engine room. Deficiency cleared.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 September 2008 Resolved
The vessel’s HF/MF radio is not operational. The vessel is required to submit a technician report attesting to the proper operation of the HF/MF radio.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2008
Resolution: Vessel provided a technicians report attesting to the proper operation of the HF/MF radio
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 12 June 2008 Resolved
The vessel has a dry deck seal for the inert gas system that is not approved by the Marine Safety Center. The vessel is required to get the dry deck seal approved by the Marine Safety Center. 46CFR32.53-10 .1
Action required: 705 - Other - as specified
Due 12 July 2008
Resolved 25 July 2008
Resolution: Double Block and Bleed approved by the Marine Safety Center.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 6 June 2006 Resolved
In 1995 crew made repairs to rescue boat hull. Class has not signed off on repairs to ensure that such repairs do not jeoperdize aministrations endorsment. Class is to attest to repairs prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2006
Resolved 8 June 2006
Resolution: Cleared per class (DNV) report.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 June 2006 Resolved
Vessels has installed a new oil content meter which has not been signed off by class. Additionally the crew was unable to demonstrate testing of the oil content meter. Class is to approve the new equipment and ensure crew can properly operate and test equipment prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2006
Resolved 8 June 2006
Resolution: Cleared per class (DNV) report.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 6 June 2006 Resolved
Inert Gas Generator was inoperable. Difience required to be rectified to the satisfaction of class prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2006
Resolved 8 June 2006
Resolution: Received Class report stating the gas oil supply line pressure regulator on the Inert Gas Generator was reported to have been replaced. The Inert Gas System was found to be in good working condition.
Engineering › Generator (propulsion/auxiliary-electric) › Generator Voltage Regulator Circuitry
Issued 8 March 2006 Resolved
Vessel had an inoperable Auxilliary Generator prior to entering port. Inbound Deviation was granted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2006
Resolution: 1 def. Issued 1 def cleared. Received technicians report attesting to satisfactory repairs. Vessel was allowed to depart port.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 15 July 2004 Resolved
No explosionmeters available on board. Must fax reciept for functional meters and proof that they are on baord the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 15 October 2004
Resolution: Recieved Class report.
Engineering › Diesel Engine (propulsion-direct drive) › Camshaft
Issued 8 December 2003 Resolved
Vsl suffered a loss of propulsion/power while transiting the Houston ship channel. Vsl shall provide attestation from the certificate issuing authority indication that the vsl remains in class for machinery.
Due 8 December 2003
Resolved 8 December 2003
Resolution: Rcvd class report attesting to repairs and satisfactory testing of the main propulsion engine. No condition of class was issued. Vsl is cleared to sail.
Deck/Cargo › Inert Gas System
Issued 4 September 2002 Resolved
Vessels inert gas system not working properly, discharging fuel overboard when trying to start system.
Condition: Placed in Improper Service
Due 17 September 2002
Resolved 6 September 2002
Resolution: Inert gas system tested to the satifaction of Class DNV.
Deck/Cargo
Issued 14 April 2001 Resolved
Class to provide information that verifies vessel's maximum design vacuum pressure for VCS.
Condition: Unknown
Due 28 April 2001
Resolved 5 May 2001
Deck/Cargo
Issued 14 April 2001 Resolved
Class to provide information attesting that vessel's VCS system is designedto discharge to discharge 1.25 times the maximum allowable transfer rate.
Condition: Unknown
Due 28 April 2001
Resolved 5 May 2001
Deck/Cargo
Issued 14 April 2001 Resolved
Class to provide information that verifies vessel's VCS design pressure.
Condition: Unknown
Due 28 April 2001
Resolved 5 May 2001
Documentation
Issued 7 December 1994 Resolved
SUBCHAPTER "O" ENDORSEMENT IS INVALID.
Condition: Unknown
Due 14 December 1994
Resolved 14 December 1994
Documentation
Issued 1 August 1994 Resolved
OIL TRANSFER PROCEDURES WERE NOT IN THE ORDER LISTED IN 33 CFR 155.750 AND WERE INCOMPLETE, IN THAT ALL INFORMATION REQUIRED BY 33 CFR 155.750 WAS NOTINCLUDED IN THE PROCEDURES.
Condition: Unknown
Due 14 December 1994
Resolved 14 December 1994
Documentation
Issued 1 August 1994 Resolved
PROVIDED CG APPROVED VESSEL RESPONSE PLAN PRIOR TO LOADING "OIL" CARGOES INUS WATERS.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Deck/Cargo
Issued 1 August 1994 Resolved
PROPERLY MARK VAPOR/LIQUID CARGO LINES PRIOR TO NEXT US PORT.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Documentation
Issued 1 August 1994 Resolved
PROVIDE OIL TRANSFER PLAN IAW 33 CFR 155.750.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Deck/Cargo
Issued 1 August 1994 Resolved
VESSEL NOT TO LOAD OR DISCHARGE CARGO REQUIRING VAPOR CONTROL SYSTEM IN US WATER UNTIL SYSTEM IS APPROVED.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Lifesaving
Issued 1 August 1994 Resolved
PROVIDE CHEMICAL TEST TUBES FOR ALL CARGOES REQUIRING TESTING PRIOR TO LOADING THESE CARGOES IN US WATERS.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Lifesaving
Issued 1 August 1994 Resolved
PROVIDE CALIBRATION KIT FOR GAS DETECTION PRIOR TO LOADING FLAMMABLE CARGOES.
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.