Records from 2016 to 2026. Most recent: inspection, 9 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 20.0 ft × 4.0 ft
Registered tonnagegross 33 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTEVE F GILBERT · DESTIN, FL, UNITED STATES · built 1988
Hull materialWood
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Simplified, Gross Ton
26 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
21 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 21
9 April 2026
Administrative Inspection · Vessel Attendance · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8345339
17 February 2026
Administrative Inspection · Vessel Attendance · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8309409
25 April 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8124245
9 April 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8109510
9 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7892881
2 February 2024
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7859822
10 January 2024
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7851589
3 April 2023
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7644993
13 January 2023
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7621159
25 April 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7437840
22 February 2022
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7400709
15 April 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7178814
21 April 2020
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6936436
27 February 2020
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6919822
2 May 2019
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6675917
25 October 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570752
17 April 2018
Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6388752
1 March 2018
Deficiency Check · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6363781
30 March 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6110305
16 August 2016
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5973541
3 March 2016
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5815283
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 April 2025
Resolved
Electric bilge pump in port stern is missing valve at overboard penetration.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2025
Resolved 25 April 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 April 2025
Resolved
Vessel's automatic bilge pump lights at the operating station to indicate operation are inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2025
Resolved 25 April 2025
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 April 2023
Resolved
Found area in starboard midship hull approximately 1 ft. above turn of the bilge where the hull material, layers of plywood and epoxy, were found to be soft and easily prodded. Vessel allowed to operate until next dry-dock scheduled nlt 29Feb2024, to make permanent repairs.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 February 2024
Resolution: All repairs to starboard hull were satisfactorily completed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 February 2022
Resolved
Inspect hull in accordance with 46 CFR 176.802. Remove stbd outboard mounting plate to asses condition of hull due to deterioration around plate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2022
Resolution: Repairs complete.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 15 April 2021
Resolved
Inspect epirb in accordance with 46 CFR 180.64. Epirb battery was expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 30 April 2021
Resolution: Epirb renewed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 April 2018
Resolved
Replace ringbuoy lifeline
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 19 April 2018
Resolution: Vessel replaced lifeline.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 April 2018
Resolved
Replace/Install securing clips on 5 identified lifejackets. max persons allowed is 46
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 19 April 2018
Resolution: Vessel replaced clips
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 April 2018
Resolved
Prove proper operation of all around white nav light (limited to daylight ops only)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 19 April 2018
Resolution: Vessel repaired light
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 17 April 2018
Resolved
Replace fire extinguisher bracket
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 19 April 2018
Resolution: Vessel replaced bracket
Construction/Loadline › Hull › Transverse Frame
Issued 1 March 2018
Resolved
Renew/Replace 6 centerline frames aft of the ladder leading below.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2018
Resolved 8 March 2018
Resolution: repairs conducted
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 16 August 2016
Resolved
Replace low charged fire extinguisher
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 16 August 2016
Resolution: Replaced fire extinguisher
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 August 2016
Resolved
Replaced masthead light with proper type
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 16 August 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 August 2016
Resolved
Replace bulb on starboard running light
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 16 August 2016
Resolution: Replaced bulb.
Communications › Radio Communications › EPIRB
Issued 16 August 2016
Resolved
Provide current EPIRB registation
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 17 August 2016
Resolution: Vessel provided EPRIB registration
Electrical › Electric Supply System (service) › Cable
Issued 16 August 2016
Resolved
Remove or ID electrical cable
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 16 August 2016
Resolution: ID cable.