LADY FRANADA

LADY FRANADA is a 1994 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in June 2026, along with 43 deficiencies and 1 casualty investigation in 2017.

Records from 2016 to 2026. Most recent: inspection, 4 June 2026.

Built
1994
Last inspected
4 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 June 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

407306
Flag
UNITED STATES
Maury page id
psix-407306

Documentation record

Registered dimensions (L × B × D)54.0 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 10 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAARK MARINE INC · MURRELLS INLET, SC, UNITED STATES · built 1994
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeUNSPECIFIED
Hull configurationTwin Hull
Hailing portGEORGETOWN, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

4 June 2026 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8392511
12 June 2025 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8158477
3 March 2025 Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8093947
22 July 2024 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7965852
22 April 2024 Type not recorded
No type recorded · Station Georgetown · USCG Southeast District (CGD-SE) · Activity 7899756
9 March 2023 Drydock Exam · Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7648719
16 May 2022 Annual Survey · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7439740
4 September 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7308172
4 June 2021 Deficiency Check · Examination of Repairs · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7201273
19 March 2021 Hull Examination · Internal Structural Exam · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7153144
1 June 2020 DAPI Audit · Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6965121
18 March 2020 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6931340
24 May 2019 DAPI Audit · Examination of Repairs · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6684224
4 March 2019 Drydock Exam · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6636285
26 March 2018 Examination of Repairs · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6379621
5 March 2018 Examination of Repairs · Administrative Inspection · Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6364743
10 August 2017 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6552320
30 July 2017 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6271957
17 May 2017 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6169243
5 April 2017 Hull Examination · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6112153
5 May 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5881991

Deficiency record · 43

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 June 2026 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Items in the first aid kit were expired.
Action required: 10 - Deficiency Rectified
Resolved 4 June 2026
Resolution: New first aid kit was purchased.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2022 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: (1) Inspection of each portable fire extinguisher, semi-portable fire extinguisher, and fixed gas fire extinguishing system to check for excessive corrosion and general condition. The portable fire extinguishers did not receive annual servicing.
Action required: 10 - Deficiency Rectified
Due 16 May 2022
Resolved 16 May 2022
Resolution: Portable fire extinguishers were service by a qualified third party.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 June 2021 Resolved
Vessels hull required to be marked with name and hailing port as identified on its Certificate of Documentation. Vessels name and hailing port are not installed/marked on the stern of the vessel as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2021
Resolved 5 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2021 Resolved
Vessel electrical system required to be equipped with overcurrent protection. Existing fuses/fuse block in way of upper console were found "wet" & "corroded".
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2021
Resolved 16 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2021 Resolved
Seating shall be provided for each passenger on board. Existing seating hardware was found loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2021
Resolved 5 September 2021
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 March 2021 Resolved
Scope of hull examinations include examination of all accessible parts of vessels underwater body, hull plating and appendages. Attending Inspector(s) noted fractures IWO port & starboard quarters (side shell @ transom).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 22 March 2021
Resolution: Attending Inspector(s) verified repairs made to fractured weldments IWO transom.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 19 March 2021 Resolved
Vessel with installed toilets are required to be equipped with waste management system. Existing Type III holding tank inlet piping was found loose/improperly installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 22 March 2021
Resolution: Attending Inspector(s) verified installation of sewage tank inlet piping.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 March 2021 Resolved
The scope of an internal structural examination include examination of vessels main strength members, internal framing and hull plating. Attending Inspector identified fractured weldments in various voids throughout the vessel (see narrative).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2021
Resolved 22 March 2021
Resolution: Attending Inspector(s) verified repairs made to fractured weldments IWO various voids.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 June 2020 Resolved
Vessel required to undergo inspection to insure vessel remains fit for route and service intended. Vessels port & starboard transoms are wasted/fractured IWO outboard motor mountings.
Action required: 705 - Other - as specified
Due 31 March 2021
Resolved 19 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 1 June 2020 Resolved
As an alternative to carrying rescue boats on vessels <65' in length, a rescue platform is authorized. Vessels rescue platform is not capable of being secured to prevent movement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2020
Resolved 19 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2020 Resolved
Ring life buoy must be fitted with an operable floating waterlight. Existing floating waterlight was found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2020
Resolved 9 June 2020
Resolution: Attending Inspector(s) verified renewal/operation of floating water light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2020 Resolved
At least one ring life buoy shall be equipped with a lifeline. Exiting lifeline was inadequate/improper type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2020
Resolved 9 June 2020
Resolution: Attending Inspector(s) verified installation of proper type/length of rescue line for ring life buoy.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 June 2020 Resolved
Vessel required to carry current/up to date navigational publications for areas transited. Existing navigational publications were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2020
Resolved 9 June 2020
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 June 2020 Resolved
Vessel required to be equipped with two (02) portable lights. Vessel is not equipped with portable light(s).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2020
Resolved 9 June 2020
Resolution: Attending Inspector(s) verified carriage of two portable lights.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 1 June 2020 Resolved
Vessel is required to carry on board a valid Certificate of Documentation (COD). Vessels current COD was not carried on board.
Action required: 705 - Other - as specified
Due 5 June 2020
Resolved 9 June 2020
Resolution: Attending Inspector(s) verified carriage of current/up to date COD.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 March 2019 Resolved
Attending Inspector noted degradation of hull welds along outboard seams of starboard sponson.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2019
Resolved 22 March 2019
Resolution: Attending Inspector verified hull weldments IWO starboard sponson.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 4 March 2019 Resolved
Attending Inspector noted fractured bottom longitudinals and transverse framing in way of starboard void #1.
Action required: 705 - Other - as specified
Due 18 March 2019
Resolved 22 March 2019
Resolution: Attending Inspector verified repairs made to bottom longitudinals in way of starboard void #1.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 March 2019 Resolved
Attending Inspector called out moderate pitting in way of starboard void #1 (internal/external).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2019
Resolved 22 March 2019
Resolution: Attending Inspector witnessed repairs made in way of starboard void #1.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 4 March 2019 Resolved
Attending Inspector called out fractured/wasted veritical box beams along transom in way of port void #4 & starboard void #4.
Action required: 705 - Other - as specified
Due 18 March 2019
Resolved 18 March 2019
Resolution: Attending Inspector witnessed repairs made in way of port/starboard transom box/channel beams.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage comminuting and disinfecting system
Issued 4 March 2019 Resolved
Attending Inspector called out wastage/pitting in way of MSD holding tank (Type III).
Action required: 705 - Other - as specified
Due 18 March 2019
Resolved 18 March 2020
Resolution: Attending Inspector authorized temporary repairs to vessels Type III MSD holding tank until next scheduled haulout in spring of 2020. Vessels owner intends to replace the existing aluminum tank with an approved poly tank.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage comminuting and disinfecting system
Issued 4 March 2019 Resolved
Attending Inspector called out wasted/pitting in way of MSD holding tank inlet (pipe) @ flexible hose connection.
Action required: 705 - Other - as specified
Due 18 March 2019
Resolved 18 March 2019
Resolution: Attending Inspector verified repairs to MSD holding tank inlet pipe/nipple/hose.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 March 2019 Resolved
Attending Inspector called out fractured weldments in way of: Port Void #1 @ 4 p/u's, Port Void #2 @ 2 p/u's, Starboard Void #2 @ 2 p/u's & Starboard Void #3 @ 1 p/u.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2019
Resolved 15 March 2019
Resolution: Attending Inspector witnessed repairs to fractured weldments.
Construction/Loadline › Hull › Longitudinal Frame
Issued 5 March 2018 Resolved
Fractured weldments IWO Port Void #1, Port Void #2, Port Void #4 & Starboard Void #1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 7 March 2018
Resolution: Attending Inspector(s) verified repairs made IWO Port & Starboard Voids.
Construction/Loadline › Hull › Bottom Plating
Issued 5 March 2018 Resolved
Crop/renew bottom plating IWO Starboard Void #1 (where marked by attending Inspector)at next scheduled drydock.
Action required: 705 - Other - as specified
Due 30 April 2019
Resolved 24 May 2019
Resolution: Attending Inspector(s) verified repairs made IWO stbd void #1.
Construction/Loadline › Hull › Longitudinal Frame
Issued 5 March 2018 Resolved
Crop/renew bottom longitudinal frame IWO Starboard Void #1 (where marked by attending Inspector) at next scheduled drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2019
Resolved 24 May 2019
Resolution: Attending Inspector(s) verified repairs made IWO stbd void #1.
Construction/Loadline › Hull › Stiffener
Issued 5 March 2018 Resolved
Crop/renew vertical stiffener IWO Port Void #4 (along transom) at next scheduled drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2019
Resolved 24 May 2019
Resolution: Attending Inspector(s) verified repairs made IWO port void #4.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 March 2018 Resolved
Vessel did not carry two (portable) flashlights.
Action required: 705 - Other - as specified
Due 4 April 2018
Resolved 22 May 2018
Resolution: Attending Inspector(s) verified carriage of two (portable) flashlights.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 March 2018 Resolved
Attending Inspector(s) noted that worn reflective tape on adult/child sized Type I PFD's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2018
Resolved 22 May 2018
Resolution: Attending Inspector(s) verified corrections made to adult/child sized Type I PFD's.
Fire Fighting › Fire Bucket › Stenciling
Issued 5 March 2018 Resolved
Fire buckets were not properly stenciled (worn).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2018
Resolved 22 May 2018
Resolution: Attending Inspector(s) verified re-stenciling of fire buckets.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 5 March 2018 Resolved
Vessels installed Type III MSD did not have operating instructions posted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 April 2018
Resolved 22 May 2018
Resolution: Attending Inspector(s) verified installation of operating instructions for installed Type III MSD.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 12 April 2017 Resolved
Vessel did not carry current/up to date navigation publications to include: Coast Pilot, CG Light List, Tide Tables, Tidal Current Tables for areas transited.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 17 May 2017
Resolution: Attending Inspector verified carriage of current/up to date navigational publications for areas transited.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 April 2017 Resolved
PFD stowage markings missing/faded.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 4 May 2017
Resolution: Attending Inspector(s) verified renewal of PFD stowage markings.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 12 April 2017 Resolved
Vessel did not have EAP program in place/posted on board.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 4 May 2017
Resolution: Attending Inspector verified the implementation/posting of EAP program.
Engineering › Fuel Oil Service System › Hose
Issued 12 April 2017 Resolved
Fuel hose between fuel filter and main engines were deteriorated, required replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 4 May 2017
Resolution: Attending Inspector verified repairs/alterations made in way of fuel lines between fuel filter assemblies and main engines.
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 April 2017 Resolved
Emergency fuel shut off markings were faded/barely readable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 4 May 2017
Resolution: Attending Inspector verified renewal of emergency fuel shut off markings/instructions.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 12 April 2017 Resolved
On board MSD system (Type III) did not have operating instructions posted/carried on board.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 4 May 2017
Resolution: Attending Inspector verified posting of operating instructions for installed Type III MSD.
Construction/Loadline › Hull › Weld
Issued 5 April 2017 Resolved
Grind/reweld fractured weldments in way of port/starboard quarter (transom @ sideshell)
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 6 April 2017
Resolution: Attending Inspector verified repairs made to fractured weldments.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2017 Resolved
Provide supports for electrical conductors running along inboard side of starboard sponson under main deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 6 April 2017
Resolution: Attending Inspector verified installation of supports/clamps in way of starboard sponson (inboard running under main deck).
Construction/Loadline › Hull › Weld
Issued 5 April 2017 Resolved
Grind/reweld fractured weldments in way of compartments: Port #4 & Starboard #2.
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 6 April 2017
Resolution: Attending Inspector verified repairs made in way of compartments: Port #4 & Starboard #2.
Construction/Loadline › Hull › Stiffener
Issued 5 April 2017 Resolved
Crop/renew fractured vertical support in way of compartment: Starboard #5 (@ transom).
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 6 April 2017
Resolution: Attending Inspector verified repairs made in way of compartment: Starboard #5.
Construction/Loadline › Hull › Weld
Issued 5 April 2017 Resolved
Grind/reweld existing weldment in way of compartment: Starboard #5 (weldment extends along top/aft of compartment).
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 12 April 2017
Resolution: Attending Inspector verified repairs made in way of compartment #5 along transom.
Stability › Watertight Integrity › General
Issued 5 April 2017 Resolved
Renew transom well watertight hatches (x2) at next scheduled haul out (Nov 2017). Temp repairs are authorized until replacement hatches can be identified/installed.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 19 March 2021
Lifesaving › Lifebuoys › Serviceable
Issued 5 April 2017 Resolved
Primary ring buoy cracked/deteriorated, requires replacement.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 4 May 2017
Resolution: Attending Inspector(s) verified replacement of ring buoy.

Casualty record · 1

10 August 2017Routine · role: Involved in a Marine Casualty · activity 6552320
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.