Inspection history · 41
18 June 2012
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4456085
4 April 2012
Drydock Extension · Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4278895
17 March 2010
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3689417
11 March 2009
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3428781
23 April 2008
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3189872
18 April 2007
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2910276
8 March 2006
MTSA Verification · COI Inspection · Cargo Tank Internal
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2601366
9 June 2005
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2390475
15 March 2005
MTSA Verification · Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2310533
8 June 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2093300
15 March 2004
Periodic Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2035895
17 April 2003
Annual Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1775383
13 May 2002
Periodic Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1629066
16 April 2002
Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1605756
28 November 2001
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 531514
15 March 2001
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1463646
29 March 2000
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1438995
13 April 1999
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1123151
22 March 1999
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1454639
23 April 1998
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 21008
24 March 1998
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1402627
21 April 1997
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1455466
25 March 1997
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1464024
21 March 1996
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 884836
28 March 1995
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 833728
19 May 1994
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 859656
12 April 1994
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 857938
2 April 1993
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1457088
10 December 1992
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 513243
17 June 1992
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1266029
30 April 1992
Hull Examination · Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 951505
15 May 1991
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1215641
2 April 1991
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1241404
1 May 1990
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 928638
30 August 1989
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1344987
11 April 1989
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1204222
27 April 1988
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1034880
13 April 1987
Hull Examination · COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1022245
6 May 1986
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1308651
5 December 1985
Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 987373
26 April 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 980034
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 17 March 2010
Resolved
DOI's not completly filled out; missing start/stop/completions times. Missing vessel names. All tankermen need to completly fill out DOI's prior to conducting cargoe transfers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 March 2010
Resolved 19 April 2010
Resolution: Posted applicable information and held training for employees on DOI procedures.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 17 March 2010
Resolved
Air bleed off oil trasnfer hose has wear/kinks; replace hose in kind.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2010
Resolved 19 April 2010
Resolution: Replaced hose.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 17 March 2010
Resolved
Exhaust on diesel engine in pumproom is partially lagged. Exhaust piping is required to be lagged fully.
Action required: 705 - Other - as specified
Due 18 April 2010
Resolved 19 April 2010
Resolution: Installed exhaust lagging.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 17 March 2010
Resolved
Empty five gallon bucket in pump room below flange gasket. Bucket was halfway filled with diesel fuel.
Action required: 705 - Other - as specified
Due 18 April 2010
Resolved 19 April 2010
Resolution: Bucket emptied and cleaned.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 17 March 2010
Resolved
Flange gasket on cargoe pipe located in the pumproom is leaking and needs to be replaced in kind,
Action required: 705 - Other - as specified
Due 18 April 2010
Resolved 19 April 2010
Resolution: Replaced gasket.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 March 2010
Resolved
Battery cap missing - not installed as per manufactor's instructions. Replace battery cap.
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 17 March 2010
Resolution: Battery cap replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 March 2010
Resolved
Electrical connections on diesel engine are covered with oily residue. Connections need to be cleaned.
Action required: 705 - Other - as specified
Due 18 April 2010
Resolved 19 April 2010
Resolution: All electrical connections on pump engine cleaned.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 11 March 2009
Resolved
Mark all cargo valves to match line diagram.
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 6 April 2009
Engineering › Fuel Oil Service System › Pump
Issued 11 March 2009
Resolved
Make permanent repairs to leaking cargo pump prime mover fuel oil lines.
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 6 April 2009
Deck/Cargo
Issued 22 March 1999
Resolved
REPLACE GASKETS AS NEEDED FOR THE PRESSURE/VACUUM VALVES COVER PLATES.
Condition: Unknown
Due 22 March 1999
Resolved 22 March 1999
Electrical
Issued 22 March 1999
Resolved
PROVIDE CIRCUIT BREAKER DIRECTORY FOR ELECTRICAL PANEL IN DECKHOUSE.
Condition: Unknown
Due 22 March 1999
Resolved 22 March 1999
Construction/Loadline
Issued 22 March 1999
Resolved
RENEW WASTED GOOSENECK VENT FOR FORWARD RAKE.
Condition: Unknown
Due 22 March 1999
Resolved 22 March 1999
Deck/Cargo
Issued 22 March 1999
Resolved
REPLACE SCREENS ON VENTS FOR POTABLE WATER STORAGE TANKS.
Condition: Unknown
Due 22 March 1999
Resolved 22 March 1999
Deck/Cargo
Issued 22 March 1999
Resolved
PLUG VENTS ON LUBE OIL PUMP DISCHARGE AND METER CONNECTIONS.
Condition: Unknown
Due 22 March 1999
Resolved 22 March 1999
Deck/Cargo
Issued 12 April 1994
Resolved
CLEAN FLAME SCREENS ON ALL P.V. VALVES AND LUBE OIL TANK VENTS.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Deck/Cargo
Issued 12 April 1994
Resolved
REPLACE #3 STBD ULLAGE FLAME SCREEN WITH ONE OF THE PROPER SIZE.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Fire Fighting
Issued 30 April 1992
Resolved
INSTALL MOUNTING BRACKET FOR PORTABLE FIRE EXTINGUISHER IN THE MIDSHIP AREAOF BARGE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1992
Resolved 30 April 1992
Deck/Cargo
Issued 30 April 1992
Resolved
REPLACE FLAME SCREENS IN ULLAGE OPENING IN #1 P/S, #2S, AND #3P CARGO TANKS_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1992
Resolved 30 April 1992
Deck/Cargo
Issued 30 April 1992
Resolved
INSTALL IDENTIFICATION SIGN ON THE REMOTE ENGINE SHUTDOWN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1992
Resolved 30 April 1992
Deck/Cargo
Issued 2 April 1991
Resolved
Mark all hoses used for oil transfer operations with the maximum allowable working pressure (MAWP) and the words "Oil Service" as described in 33CFR154.500(e)(1)(2) and as required by 33CFR155.800; prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Deck/Cargo
Issued 2 April 1991
Resolved
Provide records for each oil transfer hose showing hydrostatic test date and test pressure, manufacturing date, and burst pressure as described in 33CFR154.500(e)(g) and as required by 33CFR155.820(c); prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Deck/Cargo
Issued 2 April 1991
Resolved
Hydrostatically test all oil transfer hoses to 1 1/2 times the maximum allowable working pressure (MAWP) as required by 33CFR156.170(c)(1)(iii); prior to compliance date.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Electrical
Issued 11 April 1989
Resolved
PROVE THE ELECTRIC MOTORS AND SWITCHES IN HAZARDOUS LOCATIONS TO BE EXPLOSION PROOF AS REQUIRED BY 46 CFR 32.45, OR REPLACE WITH EXPLOSION PROOF EQUIRMENT.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Electrical
Issued 11 April 1989
Resolved
REPLACE EXPLOSION PROOF SWITCH ON THE PORT WATER PUMP.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Documentation
Issued 11 April 1989
Resolved
REWRITE OIL TRANSFER PROCEDURES TO COMPLY WITH 33 CFR 155.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Construction/Loadline
Issued 5 December 1985
Resolved
MAKE PERMANENT REPAIRS TO FRACTURE AT STBD. CORNER IN THE FORWARD RAKE. FRACTURE IS APPROX. 3FT. DOWN FROM THE MAIN DECK AT THE KNUCKLE.VESSEL MAY NOT BE PUT INTO SERVICE UNTIL REPAIRS ARE COMPLETE UNLESS #1 PORT AND STBD.CARGO TANKS ARE EMPTY
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985