Records from 1994 to 2022. Most recent: operational control imposed, 7 June 2022.
Inspection history · 75
7 June 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7470849
4 May 2022
Ballast Water Examination · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7443676
22 February 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7399125
26 January 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7383658
15 November 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7350493
10 October 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7330105
8 September 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7306060
2 August 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7274162
19 June 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7228270
11 May 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7194351
12 April 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7170982
12 April 2021
Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7173674
13 February 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7140255
30 December 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7116942
13 November 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7093832
6 October 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7071041
10 July 2020
PSC C
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7002509
8 July 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7000423
13 March 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6923925
9 December 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6869487
11 November 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6852137
7 August 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6774757
5 July 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6731714
23 May 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6690552
22 April 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6666690
11 March 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6641039
11 February 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6623463
11 February 2019
ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6623882
26 December 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6602676
19 November 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6583468
12 October 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6560008
28 August 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6525276
27 July 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6492100
29 May 2018
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6427237
16 May 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6416019
11 April 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6389747
20 November 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6309968
10 September 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6263621
24 July 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6219466
22 June 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6183489
16 May 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6147363
17 March 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6106814
16 February 2017
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6089655
27 January 2016
Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5803676
28 August 2015
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5228916
14 May 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4313634
22 February 2012
Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4249112
23 January 2012
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4229644
16 February 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3945996
24 January 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3931561
21 January 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3928252
18 November 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3893485
18 October 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3870884
10 September 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3845616
31 March 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3707707
19 March 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3698214
25 February 2010
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3685847
24 February 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3684072
17 January 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3664854
20 December 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3652356
28 July 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3548842
11 July 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3527816
27 January 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3400962
27 January 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3401034
2 December 2008
PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3372540
14 May 2008
PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3205629
22 October 2007
Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3084372
21 October 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3083881
13 October 2006
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2799073
1 September 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2183245
30 August 2004
NPV Safety Exam · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2181588
21 September 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 420421
6 August 1997
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 406397
12 June 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 404626
12 September 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 370361
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 10 July 2020
Resolved
Every rescue boat launching appliance shall be fitted with a powered winch motor. Received report that the vessels winch motor failed and the vessel can only raise and lower the lifeboat manually.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2020
Resolved 10 July 2020
Resolution: received condition from the flag state auth vessel to sail but to complete repair by 10Aug2020
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 11 February 2019
Resolved
The side ropes of the ladder shall consist of two uncovered manila ropes not less than 65mm in circumference... PSCO observed dry rot and mold on starboard side liferaft embarkation ladder.
74 SOLAS (97 Cons.) III/48.7.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2019
Resolved 4 May 2022
Resolution: PSCO's examined the side ropes of the ladders and was found to be satisfactory
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 30 January 2016
Resolved
1020 - Fire Alarm - In ships which method IIIC is adopted, a fixed fire detection and fire alarm system of an approved type complying with the requirements of Reg. 13 shall be so installed and arranged as to detect the presence of fire in all accomodation spaces and service spaces. The fire detection system on the officers deck is inoperable. 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2016
Resolution: Vessel submitted survey report showing that the faulty detector was replaced. Submitted report has been attached
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 January 2011
Resolved
2110 - Oily/Oily mixtures machinery spaces: Any ship of 400 gross tons and above but less than 10,000 gross tons shall be fitted with oil filtering equipment that will ensure that oily mixtures discharged into the sea have oil content not exceeding 15 PPM. During operational test found the diverter valve leaking by to the overboard discharge as observed through discharge line sample port. MARPOL A
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2011
Resolved 31 January 2011
Resolution: Received Class report attesting to satisfactory repairs to the three way valve on the OWS.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 24 January 2011
Resolved
0750 Fire prevention: Means shall be provided to control leaks of flammable liquids. Excessive oil found under emergency generator. SOLAS 74 (2009 Cons Ed) II-2 Reg 4.1.1
Action required: 705 - Other - as specified
Resolved 24 January 2011
Resolution: Corrected to the satisfaction of the Coast Guard prior to exam conclusion.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 February 2010
Resolved
Ship's shall be fitted with oil filtering equipment that shall ensure that any oily mixture discharged into the sea after passing though the system has an oil content not exceeding 15 PPM. Separating equipment was rendered inoperable as result of a crack in the pump's stator that occured because of a leak on teh supply side (suction) of the pump that air bound the pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2010
Resolution: Intake (suction) elbow and pump stator replaced. OWS tested satisfactorily after repair by class.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 February 2010
Resolved
The minimum fire integrity of bulkheads and decks shall be as prescribed in tables 9.5 and 9.6 of Solas II-2. The laundry room below the main deck is miising a required door leading to the engine room, as indicated on the fire control plan, the boundary sorrounding the laundry room is an A-60 boundary class shall provide a report attesting to the necessity of the door.
Condition: Unknown
Due 30 June 2010
Resolved 12 July 2010
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 February 2010
Resolved
General arrangement plans shall show clearly the various fire sections enclosed by "A" and "B" class divisions.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2010
Resolution: Class verified plans; stated that "The vessel''s Fire Safety Plan is approved by the Danish Maritime Authority and BV at the time of the building of the vessel. No change to be made unless the flag and BV head office agree."
Navigation › Piloting/Steering › Swing Meter
Issued 2 December 2008
Resolved
Provide Class report Attesting to proper operation of rudder angle indicator.
Action required: 705 - Other - as specified
Due 9 December 2008
Resolved 8 December 2008
Resolution: Class was on board (BV). rudder indicator was tested and in working order.
Navigation
Issued 12 June 1997
Resolved
PROVIDE NONSLIP SURFACE AT STEERING GEAR AS REQUIRED BY SOLAS 74/78 REG.29.13.2. CORRECT BY 12 JUL 97
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Deck/Cargo
Issued 12 June 1997
Resolved
PROVIDE OIL TRANSFER PROCEDURES AS REQUIRED BY 33 CFR 155.720.
Condition: Unknown
Due 21 September 1998
Resolved 21 September 1998