MAURY USCG vessel records Sign in
← All vessels

DANICA SUNBEAM

DANICA SUNBEAM is a 1988 freight ship. The Coast Guard has recorded 75 inspections since 1994, most recently in June 2022, along with 11 deficiencies and 38 operational controls, 4 with no removal date recorded.

Records from 1994 to 2022. Most recent: operational control imposed, 7 June 2022.

Built
1988
Last inspected
7 June 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
4 with no removal date recorded

Identity

8701260 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
407376
Flag
DENMARK
—
Maury page id
psix-407376

Inspections, by type

…with no type recorded59
Years with a record 19 calendar years (1994–2022)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it584 - Convention (Subpart B), Net Ton
1087 - Simplified, Gross Ton
1087 - Convention (Subpart B), Gross Ton
584 - Simplified, Net Ton
1788 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 75

7 June 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7470849
4 May 2022 Ballast Water Examination · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7443676
22 February 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7399125
26 January 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7383658
15 November 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7350493
10 October 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7330105
8 September 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7306060
2 August 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7274162
19 June 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7228270
11 May 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7194351
12 April 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7170982
12 April 2021 Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7173674
13 February 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7140255
30 December 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7116942
13 November 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7093832
6 October 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7071041
10 July 2020 PSC C
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7002509
8 July 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7000423
13 March 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6923925
9 December 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6869487
11 November 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6852137
7 August 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6774757
5 July 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6731714
23 May 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6690552
22 April 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6666690
11 March 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6641039
11 February 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6623463
11 February 2019 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6623882
26 December 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6602676
19 November 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6583468
12 October 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6560008
28 August 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6525276
27 July 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6492100
29 May 2018 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6427237
16 May 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6416019
11 April 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6389747
20 November 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6309968
10 September 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6263621
24 July 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6219466
22 June 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6183489
16 May 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6147363
17 March 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6106814
16 February 2017 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6089655
27 January 2016 Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5803676
28 August 2015 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5228916
14 May 2012 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4313634
22 February 2012 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4249112
23 January 2012 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4229644
16 February 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3945996
24 January 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3931561
21 January 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3928252
18 November 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3893485
18 October 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3870884
10 September 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3845616
31 March 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3707707
19 March 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3698214
25 February 2010 PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3685847
24 February 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3684072
17 January 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3664854
20 December 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3652356
28 July 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3548842
11 July 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3527816
27 January 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3400962
27 January 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3401034
2 December 2008 PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3372540
14 May 2008 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3205629
22 October 2007 Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3084372
21 October 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3083881
13 October 2006 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2799073
1 September 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2183245
30 August 2004 NPV Safety Exam · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2181588
21 September 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 420421
6 August 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 406397
12 June 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 404626
12 September 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 370361

Deficiency record · 11

11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 10 July 2020 Resolved
Every rescue boat launching appliance shall be fitted with a powered winch motor. Received report that the vessels winch motor failed and the vessel can only raise and lower the lifeboat manually.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2020
Resolved 10 July 2020
Resolution: received condition from the flag state auth vessel to sail but to complete repair by 10Aug2020
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 11 February 2019 Resolved
The side ropes of the ladder shall consist of two uncovered manila ropes not less than 65mm in circumference... PSCO observed dry rot and mold on starboard side liferaft embarkation ladder. 74 SOLAS (97 Cons.) III/48.7.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2019
Resolved 4 May 2022
Resolution: PSCO's examined the side ropes of the ladders and was found to be satisfactory
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 30 January 2016 Resolved
1020 - Fire Alarm - In ships which method IIIC is adopted, a fixed fire detection and fire alarm system of an approved type complying with the requirements of Reg. 13 shall be so installed and arranged as to detect the presence of fire in all accomodation spaces and service spaces. The fire detection system on the officers deck is inoperable. 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2016
Resolution: Vessel submitted survey report showing that the faulty detector was replaced. Submitted report has been attached
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 January 2011 Resolved
2110 - Oily/Oily mixtures machinery spaces: Any ship of 400 gross tons and above but less than 10,000 gross tons shall be fitted with oil filtering equipment that will ensure that oily mixtures discharged into the sea have oil content not exceeding 15 PPM. During operational test found the diverter valve leaking by to the overboard discharge as observed through discharge line sample port. MARPOL A
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2011
Resolved 31 January 2011
Resolution: Received Class report attesting to satisfactory repairs to the three way valve on the OWS.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 24 January 2011 Resolved
0750 Fire prevention: Means shall be provided to control leaks of flammable liquids. Excessive oil found under emergency generator. SOLAS 74 (2009 Cons Ed) II-2 Reg 4.1.1
Action required: 705 - Other - as specified
Resolved 24 January 2011
Resolution: Corrected to the satisfaction of the Coast Guard prior to exam conclusion.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 February 2010 Resolved
Ship's shall be fitted with oil filtering equipment that shall ensure that any oily mixture discharged into the sea after passing though the system has an oil content not exceeding 15 PPM. Separating equipment was rendered inoperable as result of a crack in the pump's stator that occured because of a leak on teh supply side (suction) of the pump that air bound the pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2010
Resolution: Intake (suction) elbow and pump stator replaced. OWS tested satisfactorily after repair by class.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 February 2010 Resolved
The minimum fire integrity of bulkheads and decks shall be as prescribed in tables 9.5 and 9.6 of Solas II-2. The laundry room below the main deck is miising a required door leading to the engine room, as indicated on the fire control plan, the boundary sorrounding the laundry room is an A-60 boundary class shall provide a report attesting to the necessity of the door.
Condition: Unknown
Due 30 June 2010
Resolved 12 July 2010
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 February 2010 Resolved
General arrangement plans shall show clearly the various fire sections enclosed by "A" and "B" class divisions.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2010
Resolution: Class verified plans; stated that "The vessel''s Fire Safety Plan is approved by the Danish Maritime Authority and BV at the time of the building of the vessel. No change to be made unless the flag and BV head office agree."
Navigation › Piloting/Steering › Swing Meter
Issued 2 December 2008 Resolved
Provide Class report Attesting to proper operation of rudder angle indicator.
Action required: 705 - Other - as specified
Due 9 December 2008
Resolved 8 December 2008
Resolution: Class was on board (BV). rudder indicator was tested and in working order.
Navigation
Issued 12 June 1997 Resolved
PROVIDE NONSLIP SURFACE AT STEERING GEAR AS REQUIRED BY SOLAS 74/78 REG.29.13.2. CORRECT BY 12 JUL 97
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Deck/Cargo
Issued 12 June 1997 Resolved
PROVIDE OIL TRANSFER PROCEDURES AS REQUIRED BY 33 CFR 155.720.
Condition: Unknown
Due 21 September 1998
Resolved 21 September 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.