Records from 1994 to 2023. Most recent: inspection, 25 September 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 31
25 September 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7798444
18 August 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7535966
1 June 2021
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7212473
17 June 2020
COI Inspection · Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6989142
5 June 2019
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6705869
29 May 2019
Hull Examination · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6698616
14 June 2018
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6443819
20 June 2017
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6181078
20 June 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5915244
11 June 2014
Hull Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4886460
29 May 2012
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4312945
27 July 2009
Hull Examination · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3549553
13 May 2009
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3477659
7 May 2008
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3201086
25 April 2007
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2944283
9 August 2006
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2850045
23 May 2005
MARPOL Annex V Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2366658
12 July 2004
Hull Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2142074
14 January 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1984472
3 June 2002
Hull Examination · Re-Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1625335
25 April 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1403354
17 April 2000
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1408526
4 May 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1365259
19 May 1998
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1471990
21 November 1997
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1114203
30 April 1997
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424454
1 May 1996
Hull Examination · Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1443716
11 July 1995
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 880407
15 May 1995
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 872152
27 July 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1172093
15 May 1994
Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1324757
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2021
Resolved
All vessels must have navigation lights that are in compliance. Navigation lights inoperable. Vessel restricted to daylight operations.
Rectify w/in 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2021
Resolved 14 June 2021
Resolution: Pictures recieved of operational nav lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2021
Resolved
ach floating waterlight must be attached to the lanyard with a corrosion-resistant clip. The clip must allow the waterlight to be quickly disconnected from the ring life buoy. Clip found to be connected to the waterlight and tied around ring buoy. Attach clip to lanyard around life buoy and tie to waterlight.
Rectify w/in 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2021
Resolved 14 June 2021
Resolution: Pictures recieved of satisfactory life buoy arrangement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2021
Resolved
A ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Letters on life buoy found to be faded and illegible.
Rectify w/in 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2021
Resolved 14 June 2021
Resolution: Pictures recieved of satisfactory labeling of life buoy.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 June 2020
Resolved
Vessel was found with pin hole in starboard pontoon located in forward compartment. Crop and renew to good metal and fit with proper aluminum.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2020
Resolved 24 June 2020
Resolution: Boat Yard representative presented photo/video evidence of repairs to vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2019
Resolved
All Electrical Connections shall be made in junction boxes. There are electrical connections made at the forward of the canopy that are not in a junction box.
Old T 46 CFR 183.05-50
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 12 June 2019
Resolution: Connections were placed in junction boxes.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 June 2019
Resolved
The first aid kit shall be approved under 46 160.041 or contain equivalent contents. The first aid kit was not equivalent to 160.041
46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 12 June 2019
Resolution: Compliant first aid kit purchased and on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2019
Resolved
All life buoys shall be clearly marked with the vessel name. The lettering on the ring life buoy is peeling off.
46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 12 June 2019
Resolution: Buoy re-labeled.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 5 June 2019
Resolved
Loud speaker is hanging in the forward canopy with zip ties. Permanantly attach the loudspeaker.
46 CFR 176.800
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 12 June 2019
Resolution: Permanently affixed via a U-bolt/nuts.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2018
Resolved
DC01: All electrical connections must be made within a watertight junction box. Electrical connections throughout the overhead are exposed to weather.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 16 September 2018
Resolution: Vessel provided sufficient pictures of electrical connection in junction box.
Engineering › Gasoline Engine (propulsion) › Head (4 cycle)
Issued 12 July 2004
Resolved
Provide screw type clamps on gas filter.
Due 16 July 2004
Resolved 16 July 2004
Resolution: provided
Construction/Loadline › Hull › Side Shell
Issued 12 July 2004
Resolved
provide zincs on rear of pontoon.
Due 16 July 2004
Resolved 16 July 2004
Construction/Loadline › Structures
Issued 3 June 2002
Resolved
REPAIR DAMAGE TO ALUMINUM PORT BOW BULWARK. LEGACY COMPONENT DESC: Superstructure
Action required: 705 - Other - as specified
Due 3 July 2002
Resolved 27 June 2002
Construction/Loadline › Hull
Issued 3 June 2002
Resolved
REPLACE ALL INSPECTION PORT PLUGS FOR BOTH PONTOONS.
Action required: 705 - Other - as specified
Due 3 July 2002
Resolved 27 June 2002
Lifesaving › Lifebuoys
Issued 3 June 2002
Resolved
REPLACE WATERLIGHT BATTERY WITH NON- ALKALINE TYPE.
Action required: 705 - Other - as specified
Due 3 July 2002
Resolved 27 June 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 3 June 2002
Resolved
PROVIDE MOUNTING BRACKET FOR B-I FIRE EXTINGUISHER. LEGACY COMPONENT DESC: Mounting Bracket
Action required: 705 - Other - as specified
Due 3 July 2002
Resolved 27 June 2002
Fire Fighting
Issued 4 May 1999
Resolved
INSTALL FIRE EXTINGUISHERS IN BRACKETS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 1999
Resolved 21 June 1999
Lifesaving
Issued 4 May 1999
Resolved
LABEL CHILD PFD STOWAGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 1999
Resolved 21 June 1999
Engineering
Issued 4 May 1999
Resolved
LABEL EMERGECY FUEL SHUT OFF._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 1999
Resolved 21 June 1999
Lifesaving
Issued 4 May 1999
Resolved
PROVIDE 3 RED FLARES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 1999
Resolved 21 June 1999
Lifesaving
Issued 1 May 1996
Resolved
PAINT FLARE BOX A BRIGHT COLOR, LABEL "DISTRESS SIGNALS."_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1996
Resolved 24 June 1996
Fire Fighting
Issued 1 May 1996
Resolved
SERVICE ALL FIRE EXTINGUISHERS AND MOUNT ON BRACKETS PRIOR TO OPERATING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1996
Resolved 24 June 1996
Navigation
Issued 1 May 1996
Resolved
REPAIR STARBOARD NAVIGATION LIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1996
Resolved 24 June 1996
Engineering
Issued 1 May 1996
Resolved
RECONNECT BOTH EMERGENCY FUEL SHUTOFFS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1996
Resolved 24 June 1996
Lifesaving
Issued 1 May 1996
Resolved
INSTALL 60' OF BLACK LINE ON RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1996
Resolved 24 June 1996
Fire Fighting
Issued 1 May 1996
Resolved
PROVIDE 3-2 1/2 GALLON FIRE BUCKETS WITH LANYARDS ATTACHED, LABEL EACH "FIRE BUCKET"._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1996
Resolved 24 June 1996
Lifesaving
Issued 1 May 1996
Resolved
PROVIDE CG APPROVED FIRST AID KIT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 May 1996
Resolved 24 June 1996
Lifesaving
Issued 15 May 1995
Resolved
Repair or renew ring buoy waterlight. Vessel is resricted to daylight operations until complete.
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Lifesaving
Issued 15 May 1995
Resolved
Provide 6 orange smoke signals and 6 red flares. Voyages may not exceed more than 30 minutes in duration.
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Fire Fighting
Issued 15 May 1995
Resolved
Provide 2 B-II fire extinguishers prior to carrying passengers.
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Fire Fighting
Issued 15 May 1995
Resolved
Install approximately 4 foot extension on suction side of hand fire/bilge pump.
Condition: Unknown
Due 15 May 1995
Resolved 15 May 1995
Documentation
Issued 15 May 1994
Resolved
Provide proof of licensed operator prior to operating.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994
Resolved
Stencil ring buoy and all pfd's with vessels name prior to operating.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Documentation
Issued 15 May 1994
Resolved
Affix registration numbers to port and starboard sides of hull prior to operating.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994