Records from 2016 to 2023. Most recent: inspection, 25 September 2023.
Inspection history · 9
25 September 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7798444
18 August 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7535966
1 June 2021
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7212473
17 June 2020
COI Inspection · Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6989142
5 June 2019
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6705869
29 May 2019
Hull Examination · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6698616
14 June 2018
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6443819
20 June 2017
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6181078
20 June 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5915244
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2021
Resolved
All vessels must have navigation lights that are in compliance. Navigation lights inoperable. Vessel restricted to daylight operations.
Rectify w/in 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2021
Resolved 14 June 2021
Resolution: Pictures recieved of operational nav lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2021
Resolved
ach floating waterlight must be attached to the lanyard with a corrosion-resistant clip. The clip must allow the waterlight to be quickly disconnected from the ring life buoy. Clip found to be connected to the waterlight and tied around ring buoy. Attach clip to lanyard around life buoy and tie to waterlight.
Rectify w/in 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2021
Resolved 14 June 2021
Resolution: Pictures recieved of satisfactory life buoy arrangement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2021
Resolved
A ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Letters on life buoy found to be faded and illegible.
Rectify w/in 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2021
Resolved 14 June 2021
Resolution: Pictures recieved of satisfactory labeling of life buoy.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 June 2020
Resolved
Vessel was found with pin hole in starboard pontoon located in forward compartment. Crop and renew to good metal and fit with proper aluminum.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2020
Resolved 24 June 2020
Resolution: Boat Yard representative presented photo/video evidence of repairs to vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2019
Resolved
All Electrical Connections shall be made in junction boxes. There are electrical connections made at the forward of the canopy that are not in a junction box.
Old T 46 CFR 183.05-50
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 12 June 2019
Resolution: Connections were placed in junction boxes.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 June 2019
Resolved
The first aid kit shall be approved under 46 160.041 or contain equivalent contents. The first aid kit was not equivalent to 160.041
46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 12 June 2019
Resolution: Compliant first aid kit purchased and on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2019
Resolved
All life buoys shall be clearly marked with the vessel name. The lettering on the ring life buoy is peeling off.
46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 12 June 2019
Resolution: Buoy re-labeled.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 5 June 2019
Resolved
Loud speaker is hanging in the forward canopy with zip ties. Permanantly attach the loudspeaker.
46 CFR 176.800
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 12 June 2019
Resolution: Permanently affixed via a U-bolt/nuts.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2018
Resolved
DC01: All electrical connections must be made within a watertight junction box. Electrical connections throughout the overhead are exposed to weather.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 16 September 2018
Resolution: Vessel provided sufficient pictures of electrical connection in junction box.