← All vessels
LADY MARY
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Northwest District (CGD-NW) · Other hulls named LADY MARY
LADY MARY is a 1994 passenger vessel (inspected). The Coast Guard has recorded 76 inspections since 1994, most recently in February 2026, along with 42 deficiencies and 4 casualty investigations between 2006 and 2014.
Records from 1994 to 2026. Most recent: inspection, 11 February 2026.
- Built
- 1994
- Last inspected
- 11 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 42 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 4 investigations · 2006–2014
Identity
1023307
WCY4834
407648
Flag
UNITED STATES
368229380
Maury page id
psix-407648
Inspections, by type
…with no type recorded9
Years with a record
31 calendar years (1994–2026)
The 76 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)87.0 ft × 26.0 ft × 9.0 ft
Registered tonnagegross 73 / net 44
ITC dimensions (L × B × D)87.0 ft × 26.0 ft × 9.0 ft
ITC tonnagegross 206 / net 89
BuilderFREEPORT SHIPYARD · FREEPORT, FL, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton
206 - Convention (Subpart B), Gross Ton
44 - Regulatory (Subpart C or D), Net Ton
89 - Convention (Subpart B), Net Ton
206 - Convention (Subpart B), Gross Ton
44 - Regulatory (Subpart C or D), Net Ton
89 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ7566MMSI 368229380 · active · compulsorily equipped · granted 22 January 2026, expires 22 January 2036
WDM6927MMSI 368229380 · cancelled · compulsorily equipped · granted 30 November 2021, cancelled 21 June 2023
WDK2109MMSI 367013060 · cancelled · compulsorily equipped · granted 12 April 2018, cancelled 29 November 2021
WCY4834MMSI 367013060 · cancelled · compulsorily equipped · granted 9 April 2008, cancelled 9 April 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 76
11 February 2026
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8309512
12 January 2026
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8295146
23 May 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8156089
20 February 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8081977
19 February 2025
Plan Review (Other than "T") · In-Service Inspection · Vessel Attendance
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8156801
21 March 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7885476
20 February 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7866251
11 January 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7864997
15 May 2023
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7688698
26 January 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7627738
14 April 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7435073
15 February 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7393473
15 June 2021
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7226183
13 June 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7323427
8 February 2021
DAPI Audit · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7133187
16 March 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6927552
4 February 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6914893
7 February 2019
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6621545
29 September 2018
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6552788
14 September 2018
Administrative Inspection · Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6540709
12 September 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6542659
7 March 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6367624
23 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6360443
13 February 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6354754
31 January 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6346910
8 February 2017
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6084627
8 February 2016
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5817129
19 June 2014
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4893605
12 May 2014
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4856915
10 May 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4856911
13 February 2012
Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4239545
6 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203245
15 February 2011
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3938131
26 January 2010
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3670378
8 December 2009
DAPI Audit
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3648015
17 February 2009
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3416989
31 January 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3140281
28 January 2008
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3137681
3 January 2008
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3124264
9 February 2007
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2869872
6 April 2006
Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2618580
28 March 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2613595
13 February 2006
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2584566
26 January 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2573714
17 March 2005
MTSA Verification · Periodic Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2312784
28 February 2005
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2300738
23 September 2004
MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2203043
17 February 2004
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2011771
10 February 2004
Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2004114
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978198
5 March 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1752952
4 August 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1657983
10 April 2002
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1602714
25 March 2002
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1598340
15 March 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1420476
15 March 2000
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 818370
8 March 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1404919
18 March 1999
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1378607
23 February 1999
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1372499
12 January 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 802026
19 October 1998
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 801551
18 June 1998
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 792828
2 May 1998
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1378350
23 September 1997
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1455519
4 December 1996
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371599
24 September 1996
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1360632
22 August 1996
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1446382
27 September 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1456301
26 July 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 884149
24 February 1995
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1160771
13 February 1995
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 841564
20 January 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1132976
30 November 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1180711
26 September 1994
Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1175840
20 September 1994
Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 865406
29 August 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1177265
Deficiency record · 42
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 29 January 2026
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessel is missing upper deck markings on aft entranceway to upper deck. Vessel is to clearly mark aft entranceway with maximum number of passengers according to the vessel's stability letter.
46 CFR 122.602(f)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 January 2026
Resolved
The pump may alos be connected to the bilge system so that it can serve as either a fire ump or a bilge pump. all piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. Vessel's fire main system and bilge system are not capable of running independently of each other, presentign a hazard for firefighting inside the skin of the vessel. Vessel to change piping configuration of fire main and bilge overboard with new T connection to allow both systems to run at the same time.
705c: Prior to completed credit drydock.
46 CFR 181.10-1(e) 46 CFR 181.15-5
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 20 February 2025
Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail. Both port and starboard propeller shafts in engine rooms are exposed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 February 2025
Resolved
Electrical equipment and installations must be suitable for the roll, pitch and vibration of the vessel underway. The Micro commander box for the port engine is not secured.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 March 2024
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crew member assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace.
EAP information was not displayed on board the vessel for crew members to access at all times.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 February 2021
Resolved
Vessel is required to have bilge suction and bilge lines for each watertight compartment. Verified suction from engine room, but could not pull suction from hold #2. Vessel should demonstrate proper bilge suction in all watertight compartments.
46 CFR 182.25-5
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 February 2021
Resolved
Each fire pump must read 60psi at the pump outlet. Both fire pumps could only produce 40psi at the outlets. Vessel must demonstrate proper fire pump outlet pressure of 60psi.
46 CFR 181.10-1(c)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 February 2021
Resolved
Each item of lifesaving equipment determined to not be in serviceable condition must be repaired or replaced. One life float had damaged beckets, two paddles were broken, and three lights had expired batteries. Vessel must repair or replace lifesaving equipment. Reduce persons on board to 282.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2021
Resolved
The owner or managing operator shall submit drawings describing details of any proposed alterations. Vessel must submit drawings of electrical systems to include DC/AC systems, and load analysis to MSC for review. Alterations in way of new cabeling, oversized breakers for intended service, splices, and markings were identified during inspection. Prove proper installation of electrical system.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 February 2021
Resolved
An interior or exterior opening that is temporarily closed by cover plates held in place only by hook bolts is considered open to the weather if caulking or any material are not used. The aft door on the main deck has paint covering the bolts holding the frame in place. Remove all paint from sealing surfaces and j-bolts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 February 2021
Resolved
Repair all leaks in way of fuel oil tank and hydraulic steering system.
46 CFR 182.40-5
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 8 February 2021
Resolved
Where rigid nonmetallic material is used in a piping system and penetrations through watertight bulkheads exist, an acceptable metallic shutoff valve is installed adjacent to the through bulkhead fitting. Nonmetallic piping is used on the MSD system, and penetrates the aft watertight bulkhead without a metallic shutoff valve installed. Remove duct tape around nonmetallic piping on MSD.
46 CFR 182.40-1(a)(1)(ii)
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 February 2021
Resolved
Vessel shall maintain lifesaving equipment maintenance record in a logbook.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 February 2021
Resolved
Engine room vestibule and liquor stores were missing structural fire protection to include the side and overhead of the vestibule, the engine room door, and the deck beams above the liquor stores. Install structural fire protection to bring these spaces up to A-60 standards.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 February 2021
Resolved
Vessels must have a 6 inch combing on weathertight door openings on the main deck above the margin line on all passenger vessels that operate on a Partially Protected or Exposed route. Install 6 inch combings on all main deck weathertight door entries.
46 CFR 171.124 (Old subchapter S)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 September 2018
Resolved
13101: Propulsion must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Excessive cavitation and altered maneuvering characteristics due to damage to rudder post and propeller. 46 CFR 119.200
Engineering › Freshwater System (jacketwater cooling) › Charging Tank
Issued 13 February 2018
Resolved
Jacket water head tank was removed from its mount on the engine block and affixed to the overhead of the engine room with a rope, which is an unsafe practice per 46 CFR 115.830.
Personnel › Certificates/Documents/Licenses › TWIC
Issued 8 February 2017
Resolved
Vessel personnel responsible for security duties must maintain a TWIC. Master's TWIC expired 20Dec2016. Master required to renew TWIC card.
Engineering › Fuel Oil Service System › Piping
Issued 8 February 2017
Resolved
High pressure fuel lines on both main engines are chafing. Renew tubing to original, and incorporate means to prevent chafing.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 19 June 2014
Resolved
50kw generator needs to be repaired and operate at the rated kw to the satisfaction of the attending Marine Inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 12 May 2014
Resolved
Vessels starboard main engine fractured four mounting bolts (1800lb rating). Replace and install 2,200lb mounting brackets for port engine.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 26 January 2010
Resolved
All 8 buoyant apparatus' located above the pilot house will only be considered to be in a satisfactory condition for one more year. They are beginning to crack and deteriorate and are not repairable, but are currently suitable for the service intended IAW 46CFR117.207/160.010. Require replacement with a life float or an equivalent level of safety by 26JAN11.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 31 January 2008
Resolved
-Replace expired strobe light batteries
Lifesaving › Buoyant Apparatus › Marking
Issued 9 February 2007
Resolved
Marking of vessel name was worn off of one of the buoyant apparatus.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 9 February 2007
Resolved
Retro reflective tape was found peeling off of several buoyant apparatus.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 17 March 2005
Resolved
Inproper rigging of engagment lever guard, led to pump being disabled by by said rigging.
Lifesaving › Lifebuoys › Serviceable
Issued 17 March 2005
Resolved
ring bouy had numerios puncters to the cover allowing water to penetrate.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 17 March 2005
Resolved
child life jackets and adult life jackets stored together were not clearly seperated.
Lifesaving › Rescue Boat
Issued 17 February 2004
Resolved
IAW 46 CFR 117.210, provide adequate means for recovery of a helpless person from the water. Specifically, current rescue ladder is unsafe and needs to be replaced. Demonstrate to the satisfaction of the attending Marine Inspector by 17 March 2004. Note: Vessel rescue platform (no rescue boat). LEGACY COMPONENT DESC: Boarding Ladder
Lifesaving › Buoyant Apparatus
Issued 25 March 2002
Resolved
Life floats hand hold lines wasted. Inspect all hand hold lines on all floats and repair and/or replace lines as needed prior to operating more than 1 mile from shore with passengers.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Service
Issued 25 March 2002
Resolved
Service B II fire extinguisher located in 1st deck liquor locker.
Electrical
Issued 8 March 2000
Resolved
WIRING UNDER CONSOLE WAS INPROPERLY INSTALLED. WIRING NOT WIRE TIED. INPROPER USE OF HOUSE HOLD WIRE.
Fire Fighting
Issued 8 March 2000
Resolved
NO FIRE STOP MATERIAL BETWEEN THE BULKHEAD WIRE RUN LEADING FROM THE ENGINEROOM TO THE MAIN CABIN. GASKET MATERIAL NEEDS TO BE REPLACED IN THE DOOR LEADING TO THE ENGINEROOM.
Lifesaving
Issued 8 March 2000
Resolved
FIRE HOSE BRACKET IN MAIN CABIN NOT INSTALLED.
Accommodation/Occupational Safety
Issued 8 March 2000
Resolved
ALL EMERGENCY EXITS ON MAIN DECK NOT MARKED.
Lifesaving
Issued 2 May 1998
Resolved
PROVIDE ADDITIONAL LOCATION FOR STOWING LIFEJACKETS SUCH THAT THEY ARE EVENLY DISTRIBUTED THROUGHOUT PASSENGER SPACES
Construction/Loadline
Issued 22 August 1996
Resolved
Conduct credit drydock prior to 30Nov96.
Construction/Loadline
Issued 20 January 1995
Resolved
REMOVE ALL PLUMBING AND FITTINGS IN WAY OF THE FUEL SYSTEM IN THE #6 VOID SPACE.
Construction/Loadline
Issued 20 January 1995
Resolved
REMOVE FUEL, CLEAN AND GAS FREE THE #6 VOID SPACE.
Documentation
Issued 20 January 1995
Resolved
PROPERLY DISPLAY ALL REQUIRED DOCUMENTS, IAW 46 CFR SUBCH "T".
Documentation
Issued 26 September 1994
Resolved
STABILITY TEST DATA APPROVED BY MSC-1 REQUIRED. VESSEL RESTRICTED FROM CARRIAGE OF PASSENGERS FOR HIRE UNTIL TEST DATA APPROVED.
Documentation
Issued 26 September 1994
Resolved
POST ONBOARD IN FULL VIEW OF OPERATOR APPROVED STABILITY LETTER FOR SUBJECTVESSEL. VESSEL IS RESTRICTED FROM CARRIAGE OF PASSENGER FOR HIRE UNTIL LETTER IS PROPERLY POSTED.
Casualty record · 4
28 March 2006Routine · role: Involved in a Marine Casualty · activity 2613595
19 November 2009Routine · role: Involved in a Marine Casualty · 2 injured · activity 3636732
1 September 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4717956
10 May 2014Routine · role: Involved in a Marine Casualty · activity 4856911
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.