LADY MARY is a 1994 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2016, most recently in February 2026, along with 19 deficiencies and 4 casualty investigations between 2006 and 2014.
Records from 2006 to 2026. Most recent: inspection, 11 February 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)87.0 ft × 26.0 ft × 9.0 ft
Registered tonnagegross 73 / net 44
ITC dimensions (L × B × D)87.0 ft × 26.0 ft × 9.0 ft
ITC tonnagegross 206 / net 89
BuilderFREEPORT SHIPYARD · FREEPORT, FL, UNITED STATES · built 1994
DocumentationValid · issued 5 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton 206 - Convention (Subpart B), Gross Ton 44 - Regulatory (Subpart C or D), Net Ton 89 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 29 January 2026Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessel is missing upper deck markings on aft entranceway to upper deck. Vessel is to clearly mark aft entranceway with maximum number of passengers according to the vessel's stability letter.
46 CFR 122.602(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 9 February 2026
Resolution: signage added.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 January 2026Resolved
The pump may alos be connected to the bilge system so that it can serve as either a fire ump or a bilge pump. all piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. Vessel's fire main system and bilge system are not capable of running independently of each other, presentign a hazard for firefighting inside the skin of the vessel. Vessel to change piping configuration of fire main and bilge overboard with new T connection to allow both systems to run at the same time.
705c: Prior to completed credit drydock.
46 CFR 181.10-1(e) 46 CFR 181.15-5
Action required: 705 - Other - as specified
Due 1 March 2026
Resolved 10 March 2026
Resolution: Vessel reconfigured systems to be able to run simultaneously IAW with plan approved by [name withheld] witnessed satisfactory operation of each system and piping installation.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 20 February 2025Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail. Both port and starboard propeller shafts in engine rooms are exposed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2025
Resolved 13 March 2025
Resolution: O/O provided photos of suitable guards installed over port and starboard propeller shafts.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 February 2025Resolved
Electrical equipment and installations must be suitable for the roll, pitch and vibration of the vessel underway. The Micro commander box for the port engine is not secured.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2025
Resolved 13 March 2025
Resolution: O/O provided a photo showing rhe mirco commander box for the port engine suitably secured.
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crew member assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace.
EAP information was not displayed on board the vessel for crew members to access at all times.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2024
Resolved 25 March 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 February 2021Resolved
Vessel is required to have bilge suction and bilge lines for each watertight compartment. Verified suction from engine room, but could not pull suction from hold #2. Vessel should demonstrate proper bilge suction in all watertight compartments.
46 CFR 182.25-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2021
Resolution: Vessel demonstrated proper bilge suction from each watertight compartment.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 February 2021Resolved
Each fire pump must read 60psi at the pump outlet. Both fire pumps could only produce 40psi at the outlets. Vessel must demonstrate proper fire pump outlet pressure of 60psi.
46 CFR 181.10-1(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2021
Resolution: Fire pump was satisfactorily tested.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 February 2021Resolved
Each item of lifesaving equipment determined to not be in serviceable condition must be repaired or replaced. One life float had damaged beckets, two paddles were broken, and three lights had expired batteries. Vessel must repair or replace lifesaving equipment. Reduce persons on board to 282.
Action required: 705 - Other - as specified
Resolved 12 April 2021
Resolution: Vessel destroyed condemned life float, and is not replacing but instead adjusting passenger count on COI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2021Resolved
The owner or managing operator shall submit drawings describing details of any proposed alterations. Vessel must submit drawings of electrical systems to include DC/AC systems, and load analysis to MSC for review. Alterations in way of new cabeling, oversized breakers for intended service, splices, and markings were identified during inspection. Prove proper installation of electrical system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2021
Resolved 21 June 2022
Resolution: MSC approved electrical diagram
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 February 2021Resolved
An interior or exterior opening that is temporarily closed by cover plates held in place only by hook bolts is considered open to the weather if caulking or any material are not used. The aft door on the main deck has paint covering the bolts holding the frame in place. Remove all paint from sealing surfaces and j-bolts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2021
Resolved 12 April 2021
Resolution: Removed paint and seal around tonnage opening door.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 February 2021Resolved
Repair all leaks in way of fuel oil tank and hydraulic steering system.
46 CFR 182.40-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2021
Resolution: Replaced sight glass and demonstrated leaks were rectified around fuel tank.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 8 February 2021Resolved
Where rigid nonmetallic material is used in a piping system and penetrations through watertight bulkheads exist, an acceptable metallic shutoff valve is installed adjacent to the through bulkhead fitting. Nonmetallic piping is used on the MSD system, and penetrates the aft watertight bulkhead without a metallic shutoff valve installed. Remove duct tape around nonmetallic piping on MSD.
46 CFR 182.40-1(a)(1)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2021
Resolved 13 May 2021
Resolution: Metallic valves were installed at the bulkhead and duct tape was removed.
Vessel shall maintain lifesaving equipment maintenance record in a logbook.
Action required: 10 - Deficiency Rectified
Resolved 8 February 2021
Resolution: Vessel will start maintaining a record of lifesaving equipment maintenance in logbook.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 February 2021Resolved
Engine room vestibule and liquor stores were missing structural fire protection to include the side and overhead of the vestibule, the engine room door, and the deck beams above the liquor stores. Install structural fire protection to bring these spaces up to A-60 standards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2021
Resolved 12 April 2021
Resolution: Vessel installed an A 60 fire door to engine room and liquor stores and installed structural fire protection in vestibule.
Vessels must have a 6 inch combing on weathertight door openings on the main deck above the margin line on all passenger vessels that operate on a Partially Protected or Exposed route. Install 6 inch combings on all main deck weathertight door entries.
46 CFR 171.124 (Old subchapter S)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 12 April 2021
Resolution: Vessel installed 6 inch coamings on both starboard access points.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 September 2018Resolved
13101: Propulsion must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Excessive cavitation and altered maneuvering characteristics due to damage to rudder post and propeller. 46 CFR 119.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2018
Resolved 21 September 2018
Engineering › Freshwater System (jacketwater cooling) › Charging Tank
Issued 13 February 2018Resolved
Jacket water head tank was removed from its mount on the engine block and affixed to the overhead of the engine room with a rope, which is an unsafe practice per 46 CFR 115.830.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2018
Resolved 26 February 2018
Resolution: Received picture of properly mounted head tank.
Vessel personnel responsible for security duties must maintain a TWIC. Master's TWIC expired 20Dec2016. Master required to renew TWIC card.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 8 March 2017
Resolution: Received photo copy of Master's TWIC card, expires 18FEB2022.
Engineering › Fuel Oil Service System › Piping
Issued 8 February 2017Resolved
High pressure fuel lines on both main engines are chafing. Renew tubing to original, and incorporate means to prevent chafing.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 28 February 2017
Resolution: Fuel line replaced
28 March 2006Routine · role: Involved in a Marine Casualty · activity 2613595
19 November 2009Routine · role: Involved in a Marine Casualty · 2 injured · activity 3636732
1 September 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4717956
10 May 2014Routine · role: Involved in a Marine Casualty · activity 4856911
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.