Records from 1994 to 2010. Most recent: inspection, 9 March 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 31
9 March 2010
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3697906
4 March 2010
Drydock Exam · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3689822
18 March 2009
Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3435691
19 February 2009
Administrative Inspection · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3422347
17 March 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3166105
12 December 2007
In-Service Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3114313
3 October 2006
COI Inspection · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2792673
16 March 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2602807
18 November 2005
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2535629
28 April 2005
Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2345057
15 November 2004
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2268447
23 March 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2034817
12 March 2003
Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1755824
10 December 2002
Examination of Repairs
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1719909
20 March 2002
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1495353
23 March 2001
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1427991
29 March 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1384404
22 March 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1413682
5 August 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 775660
31 March 1999
COI Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 786932
16 September 1998
Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 800541
10 March 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 783550
11 December 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 778511
16 September 1997
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 785605
23 September 1996
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1135935
3 April 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 884772
17 October 1995
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1189967
9 June 1995
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1186666
25 January 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1157086
29 September 1994
Plan Review "T" Boat · Initial Certification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 868939
19 May 1994
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1025704
Communications › Alarms/Indicators › General Alarm
Issued 18 March 2008
Resolved
Aft Vapor Detector Disconected. Repair and test.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 19 March 2008
Resolution: Corrected
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 March 2008
Resolved
Battery covers not properly secured.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 19 March 2008
Resolution: Corrected
Electrical › Electric Supply System (service) › Battery Conductor
Issued 18 March 2008
Resolved
Positive terminals exposed near battery box. Properly cover terminals.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 19 March 2008
Resolution: Corrected
Stability › Watertight Integrity › General
Issued 18 March 2008
Resolved
Loose gasket on port aft deck cover.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 19 March 2008
Resolution: Corrected
Engineering › Gasoline Engine (propulsion) › Exhaust Piping (4 cycle)
Issued 18 March 2008
Resolved
Missing bolt on the exhaust flange in the forward compartment.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 19 March 2008
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 March 2008
Resolved
Excess oil in main bilge.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 19 March 2008
Resolution: Corrected
Construction/Loadline › Hull › Weld
Issued 3 October 2006
Resolved
Provide approved plans for extensive hull modifications made to vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2006
Resolved 1 May 2007
Resolution: Approved plans provided
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 October 2006
Resolved
Provide annual service.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2007
Resolved 21 June 2007
Resolution: Corrected
Documentation › Markings/Placards › Oil Discharge Placard
Issued 3 October 2006
Resolved
Provide oil discharge placard.
Action required: 705 - Other - as specified
Due 29 May 2007
Resolved 21 June 2007
Resolution: Corrected
Stability › Incline Test › General
Issued 3 October 2006
Resolved
Provide satisfactory results of Incline Test
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2007
Resolved 21 June 2007
Resolution: Corrected
Fire Fighting › Ventilation Systems › Ducts
Issued 16 March 2006
Resolved
Prior to operation with passengers, prove proper operation of both ventilation closure louvers for engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2006
Resolved 17 March 2006
Resolution: [name withheld] witnessed sat. test of louvers.
Construction/Loadline › Hull › Transverse Frame
Issued 16 March 2006
Resolved
Prior to operation with passengers, renew wasted transverse frame in port/aft compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2006
Resolved 17 March 2006
Resolution: [name withheld] examined renewed frame. All sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 March 2006
Resolved
Prior to operation at night, or in restricted visibility, prove proper operation of port side light.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 17 March 2006
Resolution: CWO colicci witnessed sat. test of port side light.
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 15 November 2004
Resolved
Renew forward boot on forward drive shaft due to hardened/cracked rubber.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2005
Resolved 28 April 2005
Resolution: Examnied satisfactory installation of new shaft boot.
Construction/Loadline › Hull › Transverse Frame
Issued 15 November 2004
Resolved
Renew, as original, wasted transverse hat-channel bottom frame in aft compartment bilge, stbd side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2005
Resolved 28 April 2005
Resolution: Examined satisfactory repair.
Construction/Loadline › Hull › Side Shell
Issued 23 March 2004
Resolved
Properly repair small hole in aft stbd side shell.
Action required: 705 - Other - as specified
Due 25 March 2004
Resolved 25 March 2004
Resolution: Welded small hole and water tested, Test Sat.
Engineering › Bilge Water Management System
Issued 12 March 2003
Resolved
Prove proper operation of bilge pumps, bilge high water alarms and flammable vapor detection systems. LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2003
Resolved 19 March 2003
Resolution: Witnessed satisfactory test of all bilge pumps, high water alarms and flammable vapor detectors.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 12 March 2003
Resolved
Provide evidence of annual servicing for fixed CO2 systems. LEGACY COMPONENT DESC: Quantity of CO2
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2003
Resolved 19 March 2003
Resolution: Examined satisfactory evidence of servicing for fixed CO2 systems.
Pollution Prevention/Response › Prevention Equipment
Issued 20 March 2002
Resolved
Post the oil pollution placard.
Due 29 March 2002
Resolved 26 March 2002
Engineering › Bilge Water Management System
Issued 20 March 2002
Resolved
Prove proper operation of the bilge pumps. LEGACY COMPONENT DESC: Pump
Due 29 March 2002
Resolved 26 March 2002
Engineering › Gasoline Engine (propulsion)
Issued 20 March 2002
Resolved
Prove proper operation of the vapor detector.
Due 29 March 2002
Resolved 26 March 2002
Accommodation/Occupational Safety
Issued 20 March 2002
Resolved
Prove proper operation of the port side curtain.
Condition: Unknown
Due 29 March 2002
Resolved 26 March 2002
Engineering › Bilge Water Management System
Issued 20 March 2002
Resolved
Properly relabel the bilge high level alarms.
Condition: Improper/Lack of Maintenance
Due 29 March 2002
Resolved 26 March 2002
Engineering › Bilge Water Management System
Issued 20 March 2002
Resolved
Remove the debris from the bilges.
Condition: Improper/Lack of Maintenance
Due 29 March 2002
Resolved 26 March 2002
Construction/Loadline
Issued 22 March 2000
Resolved
MAKE PROPER REPAIRS TO LEAK IN PORT SIDE FORWARD WHEEL WELL TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 22 March 2000
Resolved
REPLACE WATERLIGHT.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Construction/Loadline
Issued 22 March 2000
Resolved
PROVE PROPER OPERATION OF ALL MAIN AUXILLIARY BILGE PUMPS PRIOR TO CARRYINGPASSENGERS.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 22 March 2000
Resolved
REPLACE MEDICAL KIT.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 22 March 2000
Resolved
REPLACE RING BUOY.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Construction/Loadline
Issued 3 April 1996
Resolved
CROP AND RENEW THE PORT AND STARBOARD SIDES OF THE FORWARD DECK AS MARKED DURING INSPECTION.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Construction/Loadline
Issued 17 October 1995
Resolved
PRIOR TO PLACING VESSEL IN SERVICE OR CARRYING PASSENGERS, SUBMIT A REPAIR PROPOSAL TO [name withheld] THE BOTTOM PLATING WHERE HOLED AT THE FORWARD LOWER END OF THE SHAFT TUNNEL ON BOTH PORT AND STARBOARD SIDES.
Condition: Unknown
Due 18 October 1995
Resolved 1 November 1995
Fire Fighting
Issued 17 October 1995
Resolved
PROVIDE COPY OF SERVICING REPORT ON BOTH THE 5LB AND 2OLB CO2 CYLINDERS.
Condition: Unknown
Due 18 October 1995
Resolved 1 November 1995