This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
419 - Regulatory (Subpart C or D), Net Ton
419 - Regulatory (Subpart C or D), Gross Ton
Maury page id
psix-40768
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 31
3 October 2002Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1683743
27 July 1999Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1106465
17 December 1997Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1120799
24 November 1997COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1418264
4 December 1996Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1443778
4 January 1996Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 682716
4 December 1995COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1417851
22 September 1994Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 870580
2 June 1994Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1026811
30 November 1993Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 682704
20 November 1993Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 838459
19 November 1993COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1396013
7 January 1993Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1132485
8 December 1992Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 826325
Properly mark cargo hose "OIL SERVICE" and change tested at "150 PSI" to read "MAWP 150 PSI.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Documentation
Issued 24 November 1997Resolved
Provide plans for approval of portable 280 gallon fuel tank and containment.
Condition: Unknown
Due 24 December 1997
Resolved 3 October 2002
Resolution: cleared for administrative purposes
Electrical
Issued 24 November 1997Resolved
Properly secure electric cable in stuffing box on cargo pump motor.
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Documentation
Issued 2 June 1994Resolved
VESSEL IS RESTRICTED FROM CONDUCTING CARGO TRANSFER OPERATIONS WITH CARGOESREQUIRING A VESSEL RESPONSE PLAN UNTIL PROOF OF SAID PLAN IS PRESENTED TO THE USCG._x001C_
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Electrical
Issued 19 November 1993Resolved
REPAIR ELECTRICAL CORD FOR PRIME MOVER PUMP (MOTOR).
Condition: Unknown
Due 19 November 1993
Resolved 19 November 1993
Lifesaving
Issued 8 December 1992Resolved
REPAINT "DANGER - KEEP OUT" ON ALL CARGO TANK HATCHES.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Construction/Loadline
Issued 8 December 1992Resolved
MARK NAME/HOMEPORT ON STERN IN CHARACTERS AT LEAST 4" IN HEIGHT AND REPAINTFADED DRAFT MARKINGS.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Construction/Loadline
Issued 7 November 1991Resolved
VESSEL WAS DISCOVERED WITH 2,000 GALLON AND 3,000 GALLON INDEPENDENT DECK TANKS WHICH HAD NOT BEEN APPROVED. AS THERE MAY BE DAMAGE TO THE VESSEL CAUSED BY THE ADDED WEIGHT, MAKE THE VESSEL READY FOR INTERNAL INSPECTION OF HULL AND CARGO TANKS BY COGNIZANT O.C.M.I.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Deck/Cargo
Issued 7 November 1991Resolved
2,000 GALLON DECK TANK RESTING ON WOODEN BLOCKS, UNSECURED TO DECK HAVE NOTBEEN APPROVED FOR INSTALLATION ON VESSEL. OBTAIN APPROVAL FOR OR REMOVE.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Documentation
Issued 7 November 1991Resolved
CERTIFICATE OF FINANCIAL RESPONSIBILITY (WATER POLLUTION) #818390 FOR VESSEL EXPIRED ON 01 JUL 1991. COFR WAS INVALID FROM 01 JUL 91 THROUGH 07 NOV 91.
Condition: Unknown
Due 15 November 1991
Resolved 15 November 1991
Deck/Cargo
Issued 7 November 1991Resolved
PRESSURE/VACUUM RELIEF VALVE ON 600 GALLON DECK TANK HAS BEEN IMPROPERLY REPAIRED. IT IS MISSING PARTS. REPAIR OR REPLACE TO THE SATISFACTION OF THE COGNIZANT O.C.M.I.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Deck/Cargo
Issued 7 November 1991Resolved
3,000 GALLON DECK TANK (ACTUALLY A MILK TRUCK TRAILER TANK) RESTING ON WOODEN BLOCKS, UNSECURED. OBTAIN APPROVAL FOR USE OR REMOVE.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Deck/Cargo
Issued 7 November 1991Resolved
CARGO TRANSFER SYSTEM HAS NOT BEEN TESTED AS PER 33 CFR 156.170. TESTS TO BE CONDUCTED TO THE SATISFACTION OF THE COGNIZANT O.C.M.I. PRIOR TO LOADINGFURTHER CARGO.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Construction/Loadline
Issued 21 November 1990Resolved
MAKE PERMANENT REPAIRS TO 2' FRACTURE ADJACENT TO CLEATS AT STARBOARD DECK KNUCKLE NEAR BOW.
Condition: Unknown
Due 21 November 1990
Resolved 21 November 1990
Deck/Cargo
Issued 21 November 1990Resolved
STENCIL SERVICE AND MAXIMUM ALLOWABLE WORKING PRESSURE ON TRANSFER HOSE. ALSO, PROVIDE RECORD OF TESTING CONDUCTED.
Condition: Unknown
Due 21 November 1990
Resolved 21 November 1990
Deck/Cargo
Issued 21 November 1990Resolved
RESTENCIL WARNING NOTICES ON DECK TANKS.
Condition: Unknown
Due 21 November 1990
Resolved 21 November 1990
Construction/Loadline
Issued 21 November 1990Resolved
STENCIL WARNING NOTICES ON OR ADJACENT TO CARGO TANK HATCHES.
Condition: Unknown
Due 21 November 1990
Resolved 21 November 1990
Deck/Cargo
Issued 21 November 1990Resolved
PROVIDE PRESSURE VACUUM RELIEF VALVES FOR VENT SYSTEM TO DECK TANKS AUTHORIZED TO CARRY GRADE "B" AND LOWER CARGO.
Condition: Unknown
Due 21 November 1990
Resolved 21 November 1990
Deck/Cargo
Issued 20 November 1989Resolved
PROVIDE PROOF OF ANNUAL TEST OF CARGO HOSE AND PIPING.
Condition: Unknown
Due 20 November 1989
Resolved 20 November 1989
Fire Fighting
Issued 15 November 1989Resolved
PROVIDE 2 B-II COAST GUARD APPROVED AND SERVICEABLE FIRE EXTINGUISHERS PRIOR TO NEXT OIL TRANSFER.
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Construction/Loadline
Issued 15 November 1989Resolved
DEWATER FORWARD VOID AND PROVE WATER-TIGHTNESS.
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Construction/Loadline
Issued 15 November 1989Resolved
PAINT DRAFT MARKS BELOW 6' DRAFT.
Condition: Unknown
Due 15 November 1989
Resolved 15 November 1989
Construction/Loadline
Issued 23 November 1988Resolved
MAKE TEMPORARY REPAIRS TO CIRCULAR CRACK APPROX (18" ACROSS) ON STBD SIDE OF THE HEADLOG. BOW VOID. MAKE PERMANENT REPAIRS PRIOR TO 13JAN89.
Condition: Unknown
Due 23 November 1988
Resolved 23 November 1988
Construction/Loadline
Issued 23 November 1988Resolved
REMOVE PRODUCT FROM STERN COMPARTMENT GAS FREE, DETERMINE SOURCE OF PRODUCT, PRESENT FOR CG INSPECTION.
Condition: Unknown
Due 23 November 1988
Resolved 23 November 1988
Construction/Loadline
Issued 23 November 1988Resolved
PUMP WATER FROM BOW COMPARTMENT AND PROVE COMPARTMENT IS WATERTIGHT.
Condition: Unknown
Due 23 November 1988
Resolved 23 November 1988
Construction/Loadline
Issued 23 November 1988Resolved
MAKE TEMPORARY REPAIR TO 1" FRACTURE AT CORNER OF DECK AND SIDE SHELL ON MAIN DECK AT AFT END OF CARGO TANK #3 (PORTSIDE) JUST FWD OF AFT BLKHD. MAKE PERMANENT REPAIRS PRIOR TO 13JAN89. NOTIFY LOCAL OCMI WHERE REPAIRED FOR CG INSPECTOR TO WITNESS ALL REPAIRS.
Condition: Unknown
Due 23 November 1988
Resolved 23 November 1988