Records from 1994 to 2025. Most recent: inspection, 7 November 2025.
Documentation record
Registered dimensions (L × B × D)124.7 ft × 25.6 ft × 9.8 ft
Registered tonnagegross 77 / net 52
ITC dimensions (L × B × D)124.7 ft × 25.6 ft × 9.8 ft
ITC tonnagegross 205 / net 61
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1994
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW IBERIA, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it77 - Regulatory (Subpart C or D), Gross Ton
205 - Convention (Subpart B), Gross Ton
52 - Regulatory (Subpart C or D), Net Ton
61 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 48
7 November 2025
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8265781
17 December 2024
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8049336
22 October 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8019813
13 September 2024
Load Line/Change of Employment
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8001786
3 May 2023
In-Service Inspection · Annual Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7680060
27 March 2023
Drydock Exam · Load Line/Change of Employment
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7657977
28 November 2022
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7602814
15 September 2021
COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7312050
29 June 2021
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7239113
28 May 2020
Administrative Inspection
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6967900
29 July 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6768964
9 July 2018
Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6473210
26 May 2017
COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6155922
8 November 2016
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6037589
29 June 2016
Hull Examination · Internal Structural Exam · Examination of Repairs · Annual Inspection · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5923772
19 August 2015
Periodic Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5220983
23 July 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4388500
11 June 2012
Drydock Exam · COI Inspection · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4341099
14 May 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4311335
3 May 2012
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4301363
7 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4203803
1 December 2011
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4199619
10 December 2010
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3908784
10 December 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3908839
30 March 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3705316
23 June 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3245239
16 June 2008
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3238618
18 February 2008
Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3149987
16 February 2008
Damage Survey
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3148485
7 June 2007
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2954107
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806513
21 June 2006
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2687368
8 July 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2419432
14 February 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2292495
7 June 2004
Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2090964
8 July 2003
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1839945
28 May 2002
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1620636
25 July 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 182293
5 June 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408753
20 July 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433704
29 June 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1437578
8 July 1998
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471519
3 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1112594
9 July 1997
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1407927
11 July 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367814
18 July 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403973
20 July 1994
COI Inspection · Hull Examination · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1179753
20 July 1994
Inclining Experiment · Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398135
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 September 2024
Resolved
A hatch exposed to the weather must be watertight
The following hatches were leaking when tested with hose: forward peak, engine room, generator room. Repair or replace in kind to ensure watertightness.
46 CFR 171.124(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2025
Resolution: Emergency escapes and forepeak hatches were renewed and adjusted watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 August 2018
Resolved
All lifefloats were found with frayed lines. Replace lines prior to sail.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2018
Resolved 5 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2018
Resolved
3" of fuel was discovered in the bilge of the main machinery space due to a broken valve in the fuel line. Repair valve and clean bilge prior to sail.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 September 2018
Resolved 5 November 2018
Lifesaving › Lifefloat › Markings
Issued 29 June 2016
Resolved
Vessel's name is faded and unreadable on one of the lifefloats, which needs to be repainted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 8 November 2016
Resolution: Corrected; provided photo.
Lifesaving › Lifefloat › Float Free
Issued 29 June 2016
Resolved
Did not have spacers in between lifefloats.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 8 November 2016
Resolution: Corrected; provided photo.
Lifesaving › Rescue Boat Equipment › Boat-hook/Safety Boat-hook
Issued 29 June 2016
Resolved
Missing two boat-hooks as required per "Stand-by Vessel" endorsement.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 8 November 2016
Resolution: Corrected; provided photo via email.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 29 June 2016
Resolved
Attached floating waterlight is marked with the wrong vessel's name, which needs to be changed to reflect the correct vessel's name.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 8 November 2016
Resolution: Corrected; provided photo via email.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 June 2016
Resolved
Vessel name was not clearly visible on one ring lifebuoy, and needs to be repainted. Ringbuoy also needs the current, worn out retro-reflective tape to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 8 November 2016
Resolution: Corrected; provided photo via email.
Communications › Radio Communications › VHF Radiotelephone
Issued 29 June 2016
Resolved
VHF's Digital Selective Calling is inoperable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 8 November 2016
Resolution: Corrected; provided photo via email.
Electrical › Electric Generation Source (service) › Generator
Issued 29 June 2016
Resolved
Port and Starboard side service diesel generators each are missing an engine mount bolt.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 8 November 2016
Resolution: Corrected; provided photo via email.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 29 June 2016
Resolved
Rescue platform is not capable of being securely attached to the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 8 November 2016
Resolution: Corrected; provided photo via email.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 29 June 2016
Resolved
Exhaust cooling hose clamps are loose, which need to be tightened and doubled, rather than single clamps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 8 November 2016
Resolution: Corrected; provided photo via email.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 June 2016
Resolved
Engine Room emergency light fixture is zip tied and not securely fixed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 8 November 2016
Resolution: Corrected; provided photo via email.
Fire Fighting › Fire Hoses › Condition
Issued 19 August 2015
Resolved
Port hose on the aft deck was damaged by welding sparks resulting in leak.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2015
Resolution: Received photographic evidence of satisfatory relacement of fire hose.
Construction/Loadline › Hull › Hull Plating
Issued 3 May 2012
Resolved
Vsl had a hull puncture on the port side of the bow approx. midway to the waterline.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2012
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 1 December 2011
Resolved
Rescue platform bracket that is used in the folding of the platform had a bolt hole drilled to close to the edge of the bracket leaving only approx. <1/16th inch of metal beyond the bolt leaving the bracket accessible to cracking and breaking.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2011
Stability › Watertight Integrity › Weathertight Enclosure
Issued 1 December 2011
Resolved
F/O vents contained rubber baseballs as checkballs
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2011
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 December 2011
Resolved
Rudder room indicator light on bridge was not operational
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2011
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 10 December 2010
Resolved
Vessel is to proceed to a predestinated shipyard in Morgan City and upon arrival at the shipyard contact local [name withheld] repairs are to be presented and approved to the satisfaction of the attending U.S. Coast Guard Mari
Action required: 705 - Other - as specified
Resolved 1 December 2011
Resolution: Shaft and prop was repaired.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 18 February 2008
Resolved
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 18 February 2008
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 18 February 2008
Resolved
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 18 February 2008
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 16 February 2008
Resolved
Vsl is experiencing vibrations from inboard screws. Prove proper operation of inboard screws/shafts to the satisfaction of USCG MI.
Action required: 705 - Other - as specified
Resolved 16 June 2008
Construction/Loadline › Hull › Bottom Plating
Issued 16 February 2008
Resolved
Perfom visual external hull survey to verify no structual damage resulting from grounding.
Action required: 705 - Other - as specified
Resolved 16 June 2008
Navigation › Piloting/Steering › Marine Charts
Issued 8 July 2003
Resolved
Vessel did not have local chart (No. 11347) on board at time of inspection.
Due 8 July 2003
Resolved 8 July 2003
Resolution: Corrected prior to departure.