ESCAPE is a 1994 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1994, most recently in February 2026, along with 41 deficiencies.

Records from 1994 to 2026. Most recent: inspection, 27 February 2026.

Built
1994
Last inspected
27 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC4124
407786
Flag
UNITED STATES
367019470
Maury page id
psix-407786

Inspections, by type

…with no type recorded2
Years with a record 28 calendar years (1994–2026)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 19.0 ft × 10.0 ft
Registered tonnagegross 82 / net 82
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNAVIGATOR BOATS · ELMORE, AL, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDAUPHIN ISLAND, AL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 12 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Simplified, Gross Ton
82 - Simplified, Net Ton
82 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC4124MMSI 367019470 · active · compulsorily equipped · granted 4 February 2025, expires 23 February 2035
WDB4061MMSI 366894290 · expired · compulsorily equipped · granted 20 May 2003, cancelled 20 July 2013
WCW2521MMSI not assigned · cancelled · compulsorily equipped · granted 1 March 1996, cancelled 16 December 2002
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 61

27 February 2026 Administrative Inspection · Vessel Attendance · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8293727
12 February 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8309804
10 February 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8077674
24 October 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8024058
16 August 2024 Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 7997712
2 February 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7859859
16 January 2024 Drydock Exam · Administrative Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7849810
26 October 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7824787
17 March 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7624178
9 March 2023 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7648490
4 August 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7528006
15 March 2022 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7412134
1 February 2022 Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7388765
1 November 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7345900
15 March 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7156385
27 February 2020 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6916954
27 January 2020 Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6896699
18 September 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814740
27 February 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6633248
8 November 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6577441
27 April 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6400959
5 January 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6333345
3 February 2017 Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6082171
10 March 2016 Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5831124
26 February 2016 Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5822973
19 January 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5799923
2 May 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4300303
8 February 2012 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4241197
30 March 2010 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3694596
5 February 2010 Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3673961
12 January 2010 Drydock Extension
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3658820
26 March 2009 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3440859
22 April 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3184914
2 April 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3168930
5 December 2007 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3105233
4 April 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2901646
7 March 2007 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2883267
26 April 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2634247
14 April 2006 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2624579
27 September 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2502392
30 March 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2353403
1 March 2005 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2301646
16 April 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2045454
13 January 2004 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1975247
24 June 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1825470
24 March 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1755354
7 March 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1488102
4 January 2002 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1478467
19 October 2000 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1054985
4 January 2000 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1434979
3 December 1999 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1046699
2 November 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1413629
1 December 1998 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1032896
16 November 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1472959
2 March 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1461857
20 October 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1388382
21 November 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1092008
28 October 1996 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1402344
23 October 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1414534
28 October 1994 Hull Examination · Plan Review "T" Boat · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1434186
12 October 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1180845

Deficiency record · 41

07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 March 2020 Resolved
When a deck scuttle serves as a means of escape, it must not be less than 18 inches in diameter and musty be fitted with a quick acting release and a holdback device to hold the scuttle in the open position. Means of escape which is not readily apparent to a person from both inside and outside the space must be adequately marked with 2 inch letters "EMERGENCY EXIT KEEP CLEAR." Means of escape hatch not labeled properly and hold back device does not operate properly. Discrepancies shall be rectified prior to the carriage of passengers overnight. 46CFR177.500
Action required: 705 - Other - as specified
Due 17 March 2020
Resolved 30 March 2020
Resolution: Received pictures and videos of escape hatch holdback device operating properly and escape hatch labeled properly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2019 Resolved
No vertical means of escape in fwd berthing area.Provide means of vertical escape prior to next dry dock.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2020
Resolved 17 March 2020
Resolution: Vessel installed a flush deck hatch as a secondary means of escape from the forward berthing.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 26 March 2018 Resolved
Charts are out of date, update with current version.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2018
Resolved 27 April 2018
Resolution: Vesssels operator showed proof of new charts of operating AOR.
Engineering › Bilge Water Management System › Strainer
Issued 3 February 2017 Resolved
Repair fixed bigle suction foot in lazarette.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 24 March 2017
Resolution: Bilge suction screen added.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 3 February 2017 Resolved
Fill hole with wires coming through in tank compartment, aft bulkhead.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 24 March 2017
Resolution: Filled hole with foam.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 February 2017 Resolved
Repair water light, light works but one pin is not holding.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 24 March 2017
Resolution: Water light replaced with new.
Accommodation/Occupational Safety › Ventilation › General
Issued 3 March 2016 Resolved
Vessel has a vent opening from the fuel tank space into the accommodation space. This opening must be closed-off and made watertight and/or vapor tight. IAW 46 CFR 182.35-1 (Old-T).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 March 2016
Resolved 24 March 2016
Resolution: Bulkhead was made watertight.
Construction/Loadline › Hull › Hull Plating
Issued 5 February 2010 Resolved
Make repairs to the blisters on the port as marked in accordance with 46 CFR176.802.
Action required: 705 - Other - as specified
Resolved 17 February 2010
Resolution: Made repairs to blisters on port side as marked.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 5 February 2010 Resolved
Replace both the port and starboard strut bearings.
Action required: 705 - Other - as specified
Resolved 17 February 2010
Resolution: Replaced both port and starboard strut bearings.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 16 April 2009 Resolved
Provide day shapes per Navigation Rules.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 19 May 2009
Resolution: Day shapes on board.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 April 2009 Resolved
Replace expired batteries in waterlights on forward and aft lifefloats per 46 CFR 185.726.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 19 May 2009
Resolution: Batteries were replaced.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 16 April 2009 Resolved
Derate the port generator per 46 CFR 183.320.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 19 May 2009
Resolution: Port generator is derated.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 16 April 2009 Resolved
Secure insulation on both main engine exhausts per 46 CFR 177.970.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 19 May 2009
Resolution: Insulation was secured with wire.
Engineering › Lubricating Oil Service System › Valve
Issued 16 April 2009 Resolved
Secure oil leaks on breathers for both main engines per 46 CFR 182.01-5.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 19 May 2009
Resolution: Oil leaks were secured.
Engineering › Lubricating Oil Storage/Transfer System › Drain Tank
Issued 16 April 2009 Resolved
Secure leak in oil pan attached to stbd main engine per 46 CFR 182.01-5.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 19 May 2009
Resolution: Leak was secured.
Lifesaving › Lifefloat › Float-free Link
Issued 2 April 2008 Resolved
Install a weak link of the proper size for the forward lifefloat.
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 1 May 2008
Construction/Loadline › Hull › Hull Plating
Issued 5 December 2007 Resolved
Grind out the areas marked on the hull and make repairs as per 46 CFR 176.802.
Action required: 705 - Other - as specified
Due 5 January 2008
Resolved 6 December 2007
Resolution: Grinded out the areas marked on the hull and made repairs as per 46 CFR 176.802.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 December 2007 Resolved
Make repairs to the cracks on the port side exhaust in the engine room as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 5 January 2008
Resolved 20 December 2007
Resolution: Proper repairs were made.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 5 December 2007 Resolved
Tighten the loose bolts on the forward pasenger seat ont eh starboard side of the main deck as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 5 January 2008
Resolved 20 December 2007
Resolution: Bolts were tightened.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 December 2007 Resolved
Make repairs to the broken or missing guards on the lights for the main deck as 46 CFR 183.
Action required: 705 - Other - as specified
Due 5 January 2008
Resolved 20 December 2007
Resolution: Lights were repaired.
Engineering › Sea-water System (primary cooling) › Valve
Issued 5 December 2007 Resolved
Prove proper operation of the sea valve for the port main engine as per 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 5 January 2008
Resolved 6 December 2007
Resolution: Proved proper operation of the sea valve for the port main engine as per 46 CFR 176.610.
Lifesaving › Lifefloat › Float-free Link
Issued 7 March 2007 Resolved
Provide the proper size weak link for the two lifefloats forward of the pilot house in accordance with 46 CFR 180.130.
Action required: 705 - Other - as specified
Due 7 April 2007
Resolved 5 April 2007
Resolution: Provided the proper size weak link for the two lifeflaots forward of the pilot house in accordance with 46 CFR 180.130.
Electrical › Electric Generation Source (service) › Generator
Issued 7 March 2007 Resolved
Prove that the generators are derated in way of providing data plate in accordance with 46 CFR 183.320.
Action required: 705 - Other - as specified
Due 7 April 2007
Resolved 5 April 2007
Resolution: Proved that the generators are de-rated in way of providing a data plate in accordance with 46 CFR 183.320.
Electrical › Electric Generation Source (service) › Generator
Issued 7 March 2007 Resolved
Provide data plate for port generator in accordance with 46 CFR 183.320.
Action required: 705 - Other - as specified
Due 7 April 2007
Resolved 5 April 2007
Resolution: Provided a data plate for the port generator in accordance with 46 CFR 183.320.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 14 April 2006 Resolved
Provide properly charged fire extinguisher located in main cabin forward port side 46 CFR 176.810
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2006
Resolved 14 April 2006
Resolution: Extinguisher seal was not tight; fixed and refilled.
Lifesaving › Lifefloat › Paddle
Issued 14 April 2006 Resolved
Tether paddles to lifefloats 46CFR180.200
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2006
Resolved 14 April 2006
Resolution: Paddles tethered
Lifesaving › Lifefloat › Retroreflective Material
Issued 14 April 2006 Resolved
Provide retro for lifefloat where worn NVIC 2-63
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2006
Resolved 14 April 2006
Resolution: Retro replaced
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 April 2006 Resolved
Provide retro for 4 lifejackets on bridge 46CFR185.604
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2006
Resolved 14 April 2006
Resolution: Retro replaced
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 April 2006 Resolved
Provide professional grade machinery guards over port and starboard main engine rotating machinery 46CFR177.960
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 8 September 2006
Resolution: Install machinery guards
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 14 April 2006 Resolved
Tighten port and starboard shaft logs to a slow drip 46 CFR 176.802
Action required: 705 - Other - as specified
Due 14 May 2006
Resolved 8 September 2006
Resolution: Tightened shaft logs
Lifesaving › Lifefloat › Float Free
Issued 16 March 2005 Resolved
Relocate life float to allow for a float free arrangement as required by 46 CFR 180.130(a)(2).
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 30 March 2005
Resolution: Life float was reinstalled in a location that allowed it to float freely.
Documentation › Certificates/Documents
Issued 24 March 2003 Resolved
Provide and post on board vessel the required FCC Station License as per 47 CFR Part 80. LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 23 April 2003
Resolved 24 June 2003
Resolution: Vessel posted FCC Station License.
Navigation › Piloting/Steering
Issued 24 March 2003 Resolved
Provide on board vessel current navigation publications as required by 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 23 April 2003
Resolved 24 June 2003
Resolution: Vessel provided the required Coast Pilot.
Accommodation/Occupational Safety › Medical/First Aid
Issued 24 March 2003 Resolved
Renew expired asprin and eyewash for vessel's first aid kit as per 46 CFR 184.710. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 23 April 2003
Resolved 24 June 2003
Resolution: Aspirin and eyewash were replaced for first aid kit.
Documentation › Certificates/Documents
Issued 24 March 2003 Resolved
Provide address for new owner/operator. LEGACY COMPONENT DESC: Owner/Operator Change
Due 23 April 2003
Resolved 24 March 2003
Resolution: New owner and operator changed by NVDC.
Fire Fighting
Issued 2 November 1999 Resolved
PROVE OPERATION OF AUTOMATIC SHUT DOWN OF MAIN ENGINES UPON ACTIVATION OF FIXED FIRE EXTINGUISHING SYSTEM IN ACCORDANCE WITH 46 CFR 181.420 TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 December 1999
Resolved 7 December 1999
Navigation
Issued 28 October 1996 Resolved
PROVIDE ONBOARD VESSEL FOR REVIEW, UP TO DATE CHARTS IAW 46 CFR 184.420.
Condition: Unknown
Due 23 November 1996
Resolved 10 December 1996
Construction/Loadline
Issued 28 October 1996 Resolved
MAKE PROPER REPAIRS TO RUB RAILING IAW CG NVIC 8-87.
Condition: Unknown
Due 23 November 1996
Resolved 10 December 1996
Construction/Loadline
Issued 28 October 1996 Resolved
PROVE WATERTIGHT INTEGRITY OF THE VESSEL'S COLLISION BULKHEAD IAW 46 CFR 179.310._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 November 1996
Resolved 10 December 1996
Electrical
Issued 28 October 1994 Resolved
PROVIDE SAFETY GUARD FOR A/C GENERATOR FRONT PULLEYS
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Engineering
Issued 28 October 1994 Resolved
REPLACE F/O HOSE TO THE A/C GENERATOR. CG APPROVED F/O HOSE TO MEET ASME STANDARD 1492 WITH APPROVED HOSE FITTINGS
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994

Ownership record