Records from 1994 to 2024. Most recent: inspection, 18 January 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 43
18 January 2024
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7897520
11 August 2015
COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5211630
20 August 2014
COC-MODU Renew
Type not classified · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4966776
14 July 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4378518
10 July 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4374171
15 May 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4312410
23 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4249579
7 February 2012
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4227666
10 February 2011
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3942835
18 March 2010
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3697174
21 April 2009
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3504858
24 January 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3399383
4 November 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3357273
25 June 2008
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3247645
23 July 2007
COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3006877
6 July 2006
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2696326
1 August 2005
COC-MODU Annual
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2447920
16 July 2004
COC-MODU Renew
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2135492
9 July 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2127107
28 July 2003
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1839933
10 July 2002
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1633228
16 July 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440524
20 July 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435091
24 April 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1048696
9 February 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046525
1 November 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1453680
20 October 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125117
22 July 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 774253
21 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 790929
4 March 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802027
4 November 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803390
30 September 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801601
3 August 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 795805
3 August 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1131032
28 July 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469857
22 September 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1112227
31 July 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1392743
15 July 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396552
7 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1186225
11 October 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878093
14 August 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 872405
20 July 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1417807
14 July 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1414319
Fire Fighting › Structural - A Class Divisions › Doors
Issued 27 August 2014
Resolved
Door to accommodation spaces need to be self closing. Door is missing closure device.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 August 2014
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 14 February 2012
Resolved
Repair all air leaks in Port Lifeboat. Provide OIM staement upon repairs along with pressure of each bottle.
Action required: 705 - Other - as specified
Due 14 March 2012
Resolved 18 February 2012
Resolution: Received statement from OIM attesting to the satisfactory completion of the reapirs ot the lifeboat. All of the connections were loose and none of the connections had teflon tape. Teflon tape applied and all connecitons were tightend.
Engineering › Generator (propulsion/auxiliary-electric) › Auto Transformer Circuitry
Issued 7 February 2012
Resolved
Ensure proper operation of emergency generator to rpove proper running as well as auto-start/auto-bus transfer.
Action required: 705 - Other - as specified
Due 28 February 2012
Resolved 14 March 2012
Resolution: Attended vessel and completed satisfacoty test of e-gen.
Stability › Watertight Integrity › General
Issued 7 February 2012
Resolved
Ensure all watertight doors are properly adjusted to permit proper closure.
Action required: 705 - Other - as specified
Due 14 March 2012
Resolved 14 March 2012
Resolution: Attended vessel to ensure that all doors are porperly adjusted and closing.
Lifesaving
Issued 20 July 2000
Resolved
Recharge the emergency breathing air cylinders in the starboard lifeboat that were found to be low during inspection.
Condition: Unknown
Due 26 July 2000
Resolved 26 July 2000
Lifesaving
Issued 20 July 2000
Resolved
Replace retro-reflective tape on all ring buoys and on lifeboat canopy where found deteriorated, faded or improperly applied. Must use SOLAS approved tape and apply in accordance with IMO requirements.
Condition: Unknown
Due 26 July 2000
Resolved 26 July 2000
Accommodation/Occupational Safety
Issued 20 July 2000
Resolved
Replace certain sections of helicopter deck perimeter safety netting (chainlink fence) with heavier gauge fencing to match that of the rest of the netting. Also tighten the inner and outer perimeter netting support wire cables.
Condition: Unknown
Due 26 July 2000
Resolved 26 July 2000
Lifesaving
Issued 28 July 1998
Resolved
CONDUCT AND PROPERLY LOG LINE THROWING APPLIANCE TRAINING.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Lifesaving
Issued 28 July 1998
Resolved
CONDUCT AND PROPERLY LOG MONTHLY EPIRB INSPECTIONS IN ACCORDANCE WITH 46CFR109.208.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Lifesaving
Issued 28 July 1998
Resolved
CONDUCT AND PROPERLY LOG MONTHLY LIFEBOAT MAINTENANCE IN ACCORDANCE WITH 46CFR109.301.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Lifesaving
Issued 28 July 1998
Resolved
REMOVE VOLUME CONTROLS ON ALL GENERAL ALARM SPEAKERS. PROPERLY LABEL ALL GENERAL ALARM SPEAKERS. REPAIR BAD GENERAL ALARM IN LOWER LEVEL PASSAGEWAY.REPAIR GENERAL ALARM LIGHT IN PARTS ROOM.
Condition: Unknown
Due 27 August 1998
Resolved 21 August 1998
Lifesaving
Issued 28 July 1998
Resolved
REPAIR BOTH INTERIOR LIGHTS AND REPLACE LIFELINE ON LIFEBOAT #1.
Condition: Unknown
Due 27 August 1998
Resolved 21 August 1998
Lifesaving
Issued 28 July 1998
Resolved
REPLACE 63 TYPE I PFDS.
Condition: Unknown
Due 30 July 1998
Resolved 30 July 1998
Construction/Loadline
Issued 28 July 1998
Resolved
REPLACE MISSING HATCH DOGS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Lifesaving
Issued 28 July 1998
Resolved
CROP AND RENEW WASTED AND HOLED HANDRAILS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 27 August 1998
Resolved 21 August 1998
Electrical
Issued 28 July 1998
Resolved
CONDUCT AND PROPERLY LOG EMERGENCY BATTERY TEST IN ACCORDANCE WITH 46CFR109.211.
Condition: Unknown
Due 27 August 1998
Resolved 21 August 1998
Fire Fighting
Issued 28 July 1998
Resolved
SUBMIT FOR ABS APPROVAL, REVISED FIRE CONTROL AND SAFETY PLAN.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 28 July 1998
Resolved
CONDUCT 1.1 OPERATIONAL TEST OF RELEASE GEAR OR ALTERNATE TEST SUBJECT TO THE APPROVAL OF THE COGNIZANT OCMI ON BOTH LIFEBOATS.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Unknown
Issued 28 July 1998
Resolved
COMPLY WITH ABS REPORT DATED 13JUL98 REQUIRING AN UPDATED STABILITY LETTER.
Condition: Unknown
Due 27 August 1998
Resolved 21 August 1998
Fire Fighting
Issued 28 July 1998
Resolved
CONDUCT AND PROPERLY LOG ANNUAL CALIBRATION OF O2 / LEL METERS.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Fire Fighting
Issued 28 July 1998
Resolved
MAKE THE TWO FIRE DOORS TO MESS DECK AND THE FIRE DOOR TO THE CONTROL ROOM SELF CLOSING AND LATCH.
Condition: Unknown
Due 28 August 1998
Resolved 21 August 1998
Electrical
Issued 28 July 1998
Resolved
CROP AND RENEW WASTED AND HOLED GAS TIGHT BULKHEAD BETWEEN MUD PITS AND_x001C_ PUMP ROOM.
Condition: Unknown
Due 27 August 1998
Resolved 21 August 1998
Lifesaving
Issued 28 July 1998
Resolved
CONDUCT AND PROPERLY LOG WEEKLY VISUAL INSPECTION ON LIFEBOATS IN ACCORDANCE WITH 46CFR109.301.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Lifesaving
Issued 28 July 1998
Resolved
REPAIR INTERIOR LIGHT, PROPERLY SECURE LOOSE / HANGING ELECTRICAL WIRES ANDPROVIDE FISHING KIT FOR LIFEBOAT #2.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Fire Fighting
Issued 31 July 1997
Resolved
REPAIR LEAKING GASKETS ON SUCTION VALVE FOR FIRE PUMPS.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Lifesaving
Issued 31 July 1997
Resolved
REMOVE EXPIRED MEDICINE IN FIRST AID KIT ON 2ND DECK. THIS FIRST AID KIT WAS A SPARE AND DID NOT REQUIRE REPLACEMENT.
Condition: Unknown
Due 4 August 1997
Resolved 4 August 1997
Fire Fighting
Issued 31 July 1997
Resolved
REPAIR/REPLACE LEAKING VALVE ON FIRE HOSE STATION #9.
Condition: Unknown
Due 4 August 1997
Resolved 4 August 1997
Fire Fighting
Issued 31 July 1997
Resolved
PROVIDE PROPER FIRE FIGHTING ENSEMBLES ONBOARD.
Condition: Unknown
Due 4 August 1997
Resolved 4 August 1997
Fire Fighting
Issued 31 July 1997
Resolved
REPLACE THE FOLLOWING NOZZLES: 2, 4, 6, 12, 14, 15 & 17.
Condition: Unknown
Due 4 August 1997
Resolved 4 August 1997
Lifesaving
Issued 31 July 1997
Resolved
REPLACE STEERING CABLE IN NO.2 LIFEBOAT.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Lifesaving
Issued 31 July 1997
Resolved
SECURE OVERHEAD WIRING IN NO.2 LIFEBOAT.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Lifesaving
Issued 31 July 1997
Resolved
REPAIR/REPLACE COMPASS WITH LARGE AIR BUBBLE, IN NO.2 LIFEBOAT.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Electrical
Issued 31 July 1997
Resolved
PROVE OPERATION OF TOTAL RIG SHUTDOWN AT NEXT RIG MOVE.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Lifesaving
Issued 31 July 1997
Resolved
REMOVE/WIRE UP/COVER EMERGENCY SHUTDOWN AT HELO DECK STBD LADDER.
Condition: Unknown
Due 4 August 1997
Resolved 4 August 1997
Fire Fighting
Issued 31 July 1997
Resolved
PORTABLE FIRE EXTINGUISHERS # 19 AND 45 WERE DISCHARGED.
Condition: Unknown
Due 31 July 1997
Resolved 14 August 1997
Lifesaving
Issued 31 July 1997
Resolved
PROVIDE USCG APPROVED EMERGENCY EVACUATION PLAN ON RIG.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Lifesaving
Issued 31 July 1997
Resolved
REPLACE EIGHT (8) MOUNTING BOLTS ON NO. 1 LIFEBOAT FOUNDATION.
Condition: Unknown
Due 7 August 1997
Resolved 8 August 1997
Fire Fighting
Issued 31 July 1997
Resolved
REPAIR WASTED SECTION OF FIREMAIN PIPING OVER HALON BOTTLES.
Condition: Unknown
Due 7 August 1997
Resolved 8 August 1997
Construction/Loadline
Issued 31 July 1997
Resolved
PROVE OPERATION OF BILGE SUCTION TO THE SACK ROOM.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Lifesaving
Issued 31 July 1997
Resolved
EXCESSIVE AMOUNT IN BILGE IN # 1 LIFEBOAT.
Condition: Unknown
Due 31 July 1997
Resolved 14 August 1997
Engineering
Issued 31 July 1997
Resolved
REPLACE FUEL OIL TRANSFER HOSE.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Lifesaving
Issued 31 July 1997
Resolved
PAINT OVER WARNING SIGNS FOR HELO FUELING STATION. HELO FUELING STATION NOLONGER EXISTS.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Lifesaving
Issued 31 July 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Fire Fighting
Issued 31 July 1997
Resolved
ENSURE ALL SMOKE ALARMS WORK THROUGHOUT QUARTERS.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Fire Fighting
Issued 31 July 1997
Resolved
PROVIDE INSTRUCTIONS FOR HALON SYSTEM AT HALON BOTTLES.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Electrical
Issued 31 July 1997
Resolved
LABEL ALL EMERGENCY LIGHTS WITH "E".
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Electrical
Issued 31 July 1997
Resolved
REPAIR ELECTIC CABLE IN SHAKER AREA.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Electrical
Issued 31 July 1997
Resolved
REPAIR PURGE ALARM ON DRILLERS CONSOLE.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Electrical
Issued 31 July 1997
Resolved
INSPALL PACKING GLANDS ON ELECTRIC CABLES IN MUD PIT ROOM.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Lifesaving
Issued 31 July 1997
Resolved
REPLACE HAND HELD FLARES ON RIG WITH 12 PARCHUTE TYPE FLARES.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Fire Fighting
Issued 31 July 1997
Resolved
LABEL ALL ALARM LIGHTS THROUGHOUT RIG.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Engineering
Issued 31 July 1997
Resolved
INSTALL FLAME SCREENS ON ALL BULK OIL TANK VENTS.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Lifesaving
Issued 31 July 1997
Resolved
REMOVE/CLEAN OIL FROM NO. 1 LIFEBOAT BILGE.
Condition: Unknown
Due 30 August 1997
Resolved 8 August 1997
Electrical
Issued 15 July 1996
Resolved
REMOVE /REPLACE PLASTIC TIE WRAPS ON MUD PUMPS WITH PROPER 5/8"CRS STRAPS.
Condition: Unknown
Due 15 August 1996
Resolved 26 July 1996
Electrical
Issued 15 July 1996
Resolved
RELABEL EMER. GEN. SHUTOFF VALVE (REMOTE) AND REPLACE EMER.GEN. F.O. DAY TANK SIGHT GLASS WITH HEAT RESISTANT GLASS (PYREX).
Condition: Unknown
Due 15 August 1996
Resolved 26 July 1996
Construction/Loadline
Issued 15 July 1996
Resolved
READJUST ALL DOGS ON ALL WTDS AND MUD PIT ROOM DOORS.
Condition: Unknown
Due 15 August 1996
Resolved 26 July 1996
Electrical
Issued 15 July 1996
Resolved
READJUST OVERSPEED TRIPS ON ALL THREE (3) S/S GENERATORS AND RENEW TACHOMETER ON #3 S/S GENERATOR.
Condition: Unknown
Due 15 August 1996
Resolved 26 July 1996
Lifesaving
Issued 15 July 1996
Resolved
RENEW HOT WATER PRESSURE TEMPATURE RELIEF VALVE ([OR=TO 100 PSI/210 DEG F.)
Condition: Unknown
Due 15 August 1996
Resolved 26 July 1996
Fire Fighting
Issued 15 July 1996
Resolved
PROPERLY RELABEL HALON INSTRUCTIONS AT BOTTLES IN SACK ROOM.
Condition: Unknown
Due 15 August 1996
Resolved 26 July 1996
Lifesaving
Issued 15 July 1996
Resolved
PROVE U.L. OR F.M. APPROVAL ON FORKLIFT.
Condition: Unknown
Due 15 August 1996
Resolved 26 July 1996
Documentation
Issued 15 July 1996
Resolved
AMEND SOPEP/RENEW COFR TO REFLECT NEW OWNER/OPERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 August 1996
Resolved 25 July 1996
Deck/Cargo
Issued 15 July 1996
Resolved
CONDUCT ANNUAL TEST OF CRANES FOR 1996.
Condition: Unknown
Due 15 August 1996
Resolved 26 July 1996
Lifesaving
Issued 15 July 1996
Resolved
PROVIDE DATA PLATE FOR #6 P-TANK AND DRILL FLOOR AIR RECEIVER. ALSO MAKE AIR RECEIVERS AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 15 August 1996
Resolved 26 July 1996
Electrical
Issued 20 July 1995
Resolved
REPAIR/REPLACE EXPOSED ELECTRICAL WIRING INSIDE LIGHTING PANEL 3Q UW 120/208V IN MUD PUMPROOM.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Lifesaving
Issued 20 July 1995
Resolved
REPAIR AUTOMATIC DOOR CLOSURES TO MUD PIT ROOM.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Construction/Loadline
Issued 20 July 1995
Resolved
PROVE PROPER OPS OF BILGE PUMPS.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Electrical
Issued 20 July 1995
Resolved
REPLACE 2 FUEL LINES AT FUEL SUPPLY AND RETURN AT BOTH SHUT-OFF VALVES ON EMERGENCY GENERATOR WITH AN APPROVED TYPE.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Electrical
Issued 20 July 1995
Resolved
INSTALL EMERGENCY FUEL SHUT-OFF VALVE TO EMERGENCY GENERATOR OUTSIDE GENERATOR HOUSE.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Documentation
Issued 20 July 1995
Resolved
PROVEIDE ANNUAL ABS CRANE SURVEY REPORT.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Electrical
Issued 20 July 1995
Resolved
REMOVE 480 TRANSFORMER WITH 60AMP BREAKER AND ASSOCIATED WIRING FROM EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Lifesaving
Issued 20 July 1995
Resolved
PERFORM SAT FIRE DRILL.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Electrical
Issued 20 July 1995
Resolved
SUBMIT PROPOSAL FOR TESTING LOW LUBE OIL TRIP TO ALL 3 MAIN GENERATOR UNITSAND PROVE PROPER OPERATION OF LOW LUBE OIL TRIPS TO ALL MAIN GENERATORS. SUBMIT REPORTS TO MSO PORT ARTHUR, TEXAS.
Condition: Unknown
Due 20 July 1995
Resolved 20 July 1995
Documentation
Issued 20 July 1995
Resolved
PROVIDE ANNUAL ABS IMO MODU SURVEY REPORT.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Lifesaving
Issued 20 July 1995
Resolved
REPLACE LIFE RINGS NEXT TO LIFE CAPSULE #1 AND BY DOWELL UNIT/STBD LEG.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Fire Fighting
Issued 20 July 1995
Resolved
CROP/RENEW WASTED FIREMAIN RISER TO FIRE STATION #9. PERFORM HYDROSTATIC TEST OF RENEWED PIPING TO 1.5 TIMES NORMAL WORKING PRESSURE OF PIPE.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Fire Fighting
Issued 20 July 1995
Resolved
REPLACE BAD FIRE HOSES AT FIRE STATIONS #11 AND #20.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Lifesaving
Issued 20 July 1995
Resolved
REPLACE 4 BAD LIFE PRESERVERS ON DRILL FLOOR.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Electrical
Issued 20 July 1995
Resolved
REPAIR EMERGENCY LIGHT IN 2ND DECK ACCOMMODATIONS HALLWAY.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Electrical
Issued 20 July 1995
Resolved
PROVE PROPER OPS OF ALL 3 GENERATOR UNITS IN MOTOR ROOM-OVEERSPEED TRIPS.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Lifesaving
Issued 20 July 1995
Resolved
INSTALL WARNING PLACARD IN MOTOR ROOM BY SIREN AND BY #1 GENERATOR TO READ "WHEN ALARM SOUNDS-VACATE AT ONCE. HALON BEING RELEASED."
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Lifesaving
Issued 20 July 1995
Resolved
PAINT HALON SIREN IN MOTOR ROOM RED.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Fire Fighting
Issued 20 July 1995
Resolved
TROUBLESHOOT/REPAIR FIRE STATION #6 AND FIRE STATION NEXT TO DOWELL UNIT/STBD LEG DUE TO LACK OD FIREMAIN PRESSURE.
Condition: Unknown
Due 20 August 1995
Resolved 31 July 1995
Lifesaving
Issued 14 July 1994
Resolved
PROVIDE LINE FOR LIFE RINGS AMIDSHIPS ON EITHER SIDE OF RIG.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Construction/Loadline
Issued 14 July 1994
Resolved
RENEW GRATING PORT SIDE MAIN DECK BOW LEG.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Electrical
Issued 14 July 1994
Resolved
RENEW FAULTY EXPLOSION PROOF FITTINGS IN HAZARDOUS LOCATIONS.
Condition: Unknown
Due 2 August 1994
Resolved 8 September 1994
Lifesaving
Issued 14 July 1994
Resolved
PROVIDE EYE WASH STATIONS IN MUD PIT ROOM AND RIG FLOOR.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Accommodation/Occupational Safety
Issued 14 July 1994
Resolved
REPAIR LEAK IN CREW BATHROOM AND PROVIDE SUPPORTS FOR RAILING INSIDE ACCOM SPACE.
Condition: Unknown
Due 2 August 1994
Resolved 8 September 1994
Deck/Cargo
Issued 14 July 1994
Resolved
PROVIDE DOCUMENTATION OF ANNUAL CRANE SURVEY BY ABS OR ICGB.
Condition: Unknown
Due 2 August 1994
Resolved 8 September 1994
Construction/Loadline
Issued 14 July 1994
Resolved
CROP & RENEW WASTED AREA IN MUD PIT ROOM.
Condition: Unknown
Due 23 July 1994
Resolved 8 September 1994
Documentation
Issued 14 July 1994
Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Electrical
Issued 14 July 1994
Resolved
PRIOR TO CONDUCTING DRILLING OPS RENEW WIRING SUPPORTS IN MUD PIT ROOM.
Condition: Unknown
Due 23 July 1994
Resolved 8 September 1994
Navigation
Issued 14 July 1994
Resolved
RENEW BULB IN PORT RUNNING LIGHT.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Documentation
Issued 14 July 1994
Resolved
PROVIDE PIC AND CRANE OPERATOR DESIGNATION LETTERS.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Lifesaving
Issued 14 July 1994
Resolved
ALARM BEACON IN GENERATOR ROOM BURNT OUT.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Accommodation/Occupational Safety
Issued 14 July 1994
Resolved
RENEW LEG SUPPROT TO NO.2 BULK AIR TANK.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Electrical
Issued 14 July 1994
Resolved
REPLACE WOOD CABLE RUN SUPPORTS WITH STEEL.
Condition: Unknown
Due 8 September 1994
Resolved 8 September 1994
Electrical
Issued 14 July 1994
Resolved
TIGHTEN INSTRUMENT PANEL ON MAIN GENERATOR.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Construction/Loadline
Issued 14 July 1994
Resolved
BACK GOUGE AND REWELD INSERT IN MAIN DECK ABOVE GENERATOR ROOM.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Engineering
Issued 14 July 1994
Resolved
CLEAN/REPAIR ALL VENT SCREENS MAIN DECK.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Engineering
Issued 14 July 1994
Resolved
PROPERLY LABEL FUEL OIL TRANSFER SHUTDOWN, EMERGENCY FUEL & VENT SHUTDOWN SWITCHES ON MAIN DECK WITH 1/2" RED LETTERING.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Lifesaving
Issued 14 July 1994
Resolved
COMPLETE REFURBISHMENT OF LIFE JACKESTS.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Lifesaving
Issued 14 July 1994
Resolved
RENEW FUEL TANK TO #1 LIFEBOAT.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Accommodation/Occupational Safety
Issued 14 July 1994
Resolved
RENEW ATTACHMENTS FOR NO.5 BULK AIR TANK LADDER.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Unknown
Issued 14 July 1994
Resolved
RENEW BURNT OUT HELIDECK LIGHT, PERIPHERY NETTING AND DAMAGED CABLE.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Construction/Loadline
Issued 14 July 1994
Resolved
READJUST VARIOUS WTD'S.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Fire Fighting
Issued 14 July 1994
Resolved
PROVIDE INSTRUCTIONS FOR FIXED CO2 SYSTEM AT PAINT LOCKER.
Condition: Unknown
Due 2 August 1994
Resolved 8 September 1994
Electrical
Issued 14 July 1994
Resolved
LABEL AND PROVE PROPER OPERATION OF EMERGENCY GENERATOR FUEL SHUTDOWN.
Condition: Unknown
Due 14 July 1994
Resolved 8 September 1994
Accommodation/Occupational Safety
Issued 14 July 1994
Resolved
PROVIDE SUFFICIENT COOLING AIR FOR GALLEY REFRIGERATION COMPRESSORS.
Condition: Unknown
Due 2 August 1994
Resolved 8 September 1994