NATIVE SON'S

NATIVE SON'S is a 1994 passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 1994, most recently in August 2025, along with 156 deficiencies and 2 operational controls.

Records from 1994 to 2025. Most recent: inspection, 13 August 2025.

Built
1994
Last inspected
13 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM4645
407892
Flag
UNITED STATES
367486010
Maury page id
psix-407892

Inspections, by type

Years with a record 30 calendar years (1994–2025)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)37.0 ft × 13.5 ft × 7.0 ft
Registered tonnagegross 23 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPATRICK A BRADLEY · CANTONMENT, FL, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPENSACOLA, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 17 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Gross Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM4645MMSI 367486010 · active · compulsorily equipped · granted 3 July 2021, expires 3 July 2031
WDF7586MMSI 367486010 · expired · compulsorily equipped · granted 14 April 2011, cancelled 19 June 2021
WCZ9907MMSI not assigned · expired · compulsorily equipped · granted 16 August 2000, cancelled 16 October 2010
WCR6725MMSI not assigned · expired · compulsorily equipped · granted 18 May 1995, cancelled 23 July 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 49

13 August 2025 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8209371
8 January 2025 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8060120
16 September 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8003278
9 August 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7764274
7 March 2023 Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7675543
18 May 2022 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7453686
11 August 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7283376
23 March 2021 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7161170
27 April 2020 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6944493
20 August 2019 Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6789511
6 March 2019 Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6637344
2 August 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6499331
28 February 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6364117
10 October 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6285588
21 August 2017 DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6247749
1 March 2017 Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6097306
21 April 2016 COI Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5859187
15 September 2015 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5719424
21 October 2014 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5011318
25 July 2012 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4389847
13 July 2011 Drydock Exam · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4080243
25 February 2009 Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3423548
17 September 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3326956
23 October 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3085231
4 April 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2904916
9 March 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2884999
4 October 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2793779
23 May 2006 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2656505
9 August 2005 COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2451400
11 March 2005 Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2307902
28 December 2004 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2265624
21 June 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2106198
12 September 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1903301
8 July 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1825259
10 June 2003 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1814101
21 March 2003 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1760917
9 July 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1646315
2 August 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1075083
16 May 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1064179
28 March 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1062397
27 July 2000 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 821817
26 May 1999 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1106238
16 March 1999 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1467145
27 April 1998 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 800270
17 March 1998 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1455564
21 March 1997 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1416464
22 March 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1394491
24 March 1995 Plan Review "T" Boat · Initial Construction-Excluding Oversight · Hull Examination · Deficiency Check · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1185296
8 September 1994 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 860700

Deficiency record · 156

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 September 2025 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel did not have 3 serviceable fire buckets on board during the time of inspection. 46 CFR 181.610
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2025
Resolved 9 October 2025
Resolution: Observed new fire buckets onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 September 2025 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. The Starboard engine was missing the engine mounting hardware on one of the engine mounts. 46 CFR 185.100
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2025
Resolved 9 October 2025
Resolution: New mounting hardware installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2025 Resolved
Where an exhaust pipe passes through a watertight bulkhead, the watertight integrity of the bulkhead must be maintained. In the steering compartment the fiberglass section of the exhaust exiting through the transom was leaking water into the space. 46 CFR 182.430(f)
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2025
Resolved 9 October 2025
Resolution: Piping satisfactorily repaired.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 September 2025 Resolved
Nav Charts and Pubs appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Vessel was using cell phone, but did not have the sections for their intended route saved or downloaded. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 9 October 2025
Resolution: Observed that all required charts and publication were onboard the vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2025 Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. In the engine room the wiring needs to be properly fitted to hangers. 46 CFR 183.340
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 9 October 2025
Resolution: Observed all wiring properly fitted in hangers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 4 September 2025 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Vessel replaced a wire and did not make the penetration watertight after new install. 46 CFR 179.320
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 9 October 2025
Resolution: Observed that th penetration was properly sealed and water/vapor tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 September 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Port engine had a fuel leak on a loose fuel line which was tightened during the time of inspection. 46 CFR 182.100
Action required: 10 - Deficiency Rectified
Due 4 September 2025
Resolved 4 September 2025
Resolution: corrected during the time of the inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 September 2025 Resolved
propulsion Machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed. The shaft packing had to be tightened during the time of inspection to eliminate excessive water leakage. 46 CFR 182.05-1
Action required: 10 - Deficiency Rectified
Due 4 September 2025
Resolved 4 September 2025
Resolution: corrected during the time of the inspection.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 January 2025 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Marine inspector observed no fire detection system located in accommodation space. Vessel shall install a fire detection system in accommodation space. 46 CFR 181.405 (c)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2025
Resolution: Vessel owner installed interconnected smoke detectors. all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 8 January 2025 Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. The method of opening a means of escape must be obvious, rapid, and of adequate strength. Handles and securing devices must be permanently installed and not capable of being easily removed. A door, hatch or scuttle must open towards the expected direction of escape from the space served. Marine inspector observed forward emergency escape only operable from inside the space. Vessel shall ensure the escape hatch is operable from both inside and outside the space. 46 CFR 177.500 (h)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2025
Resolution: Escape hatch was repaired, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 December 2024 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. MI observed life jackets were fitted with non-approved retroreflective material. Use Type I retroreflective material meeting 164.018.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2024
Resolution: Vessel operator procred and pplied appropriately approved SOLAS retroreflective tape on life jacket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2024 Resolved
All vessel except non-self-propelled vessels shall be provided with suitable steering apparatus. MI observed excessively corroded hydraulic hose fittings. 46 CFR 183.30-1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 20 December 2024
Resolution: Vessel replaced hydraulic hoses with CG approved hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 November 2024 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high-water level in each of the following normally unmanned spaces A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. MI observed void area with non-watertight closure on maindeck without an installed high level alarm.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 20 December 2024
Resolution: Vessel rep installed new high level alarm.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 September 2024 Resolved
A vessel to which this subchapter applies may not be operated without having onboard a valid U.S. Coast Guard Certificate of Inspection. During admin inspection MI noticed vessels COI drop dead date was 06SEP2024.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2024 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed. MI observed that the starboard reduction gear shift linkage bracket was held improperly secured. Vise grips pliers were being used in place of a bolt. 46 CFR 182.05-1
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 20 December 2024
Resolution: Vessel replaced with proper bolt and removed vice grips.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2024 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed. MI observed that the starboard shaft had excessive leakage into the engine room.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 20 December 2024
Resolution: Vessel rep conducted maintenance to ensure leakage reduced significantly
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 September 2024 Resolved
A vessel on a limited coastwise route must carry— Six hand red flare distress and Six hand orange smoke distress signals. MI observed 0 flares onboard at the time of inspection.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 20 December 2024
Resolution: Vessel rep procured proper amount of distress signals
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 16 September 2024 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. MI observed 1 hole in bulkhead with battery cable running through without being sealed or made watertight.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 20 December 2024
Resolution: Vessel rep sealed battery cable penetration with sealant.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 September 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Additionally, a visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. MI observed the fwd bilge pump visual indicator at the control station was not operational, and the fwd high water level visual alarm was not operational. Repair visual indicator for fwd bilge and high water level at operating station.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2024
Resolution: Operator wired operating station bilge light appropriately and provided video evidence of proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 September 2024 Resolved
A vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less than 24 inches in diameter; and Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. MI observed life buoy to be in state of disrepair, life buoy faded, solas tape worn and life lines dry rotten.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 20 December 2024
Resolution: Vessel rep procured new life buoy and life line.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 September 2024 Resolved
For a life float, must be approved under approval series 160.027-2 or other standard specified by the Commandant. MI observed life float installed with non-approved retro-reflective tape. Use Type II retroreflective material meeting 164.018 on each side and end of life float. 46 CFR 180.200 (a)(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2024
Resolution: Vessel operator procred and pplied appropriately approved SOLAS retroreflective tape on life float.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 September 2024 Resolved
The lights prescribed in these Rules (Subpart C) shall have an intensity as specified in Annex I to these Rules (33 CFR part 84), so as to be visible at the following minimum ranges: (ii) A sidelight, 2 miles;(iii) A sternlight, 2 miles. MI observed stern and port light to be inoperable. 33 CFR 83.22(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2024
Resolution: Vessel rep repaired inoperable running lights.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 September 2024 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. MI observed deck rails with missing, loose mounting hardware. 46 CFR 177.900
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2024
Resolution: Deck rails had hardware replaced and in good condition
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 September 2024 Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. MI found vessel to not have a EPIRB Test log, create and log test accordingly. 46 CFR 185.728(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2024
Resolution: Vessel rep created new log book for maintenance and drills.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 September 2024 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. 46 CFR 185.520(a)(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2024
Resolution: Vessel rep created new log book for maintenance and drills.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 September 2024 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. 46 CFR 185.524(a)(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2024
Resolution: Vessel rep created new log book for maintenance and drills.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 September 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2024
Resolution: Vessel rep procured new first aid kit.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 16 September 2024 Resolved
Each officer employed on any vessel subject to this subchapter must have his or her license or merchant mariner credential onboard and available for examination at all times when the vessel is operating. Vessel’s master was unable to produce a MMC. 46 CFR 185.402
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2024
Resolution: Vessel master had proof of properly endorsed MMC
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 September 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided, or such greater number as necessary to provide a life jacket for each person being carried that is smaller than the lower size limit of the adult life jackets provided to meet this section. MI observed 7 life jackets in unsatisfactory condition due to water intrusion, and mold. 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 December 2024
Resolution: Vessel rep procured new life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 September 2023 Resolved
Vessel's port engine lube oil pressure gauge were inoperable at the helm 46 CFR 182.20-5 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2023
Resolved 18 September 2023
Resolution: Received objective evidence of operational oil pressure gauge.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 5 September 2023 Resolved
Vessel's COD was expired
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2023
Resolution: MI verified copy of valid COD from NVMC
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 September 2023 Resolved
Vessel's hyrdostatic release connected to EPIRB was found to be expired 46 CFR 182.40-1(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2023
Resolution: MI verified installation of new hydrostatic release
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 September 2023 Resolved
Vessel's fuel shutoff at day tank became inoperable during testing 46 CFR 182.20-40 (b)(3)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2023
Resolution: MI verified fuel shutoff repair and witnessed proper operation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 September 2023 Resolved
Marine inspection team was unable to test suction of bilge pump in engine compartment due to an accumulation of oily waste water 46 CFR 182.25-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2023
Resolution: MI witnessed operation of bilge pump in engine compartment
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 September 2023 Resolved
Vessel's FCC permit was expired 47 CFR 80.13(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 15 September 2023
Resolution: MI verified current FCC permit
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 September 2023 Resolved
Batteries were found expired on the 02 ring buoy's water lights 46 CFR 180.30-1 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 14 September 2023
Resolution: MI verified batteries were valid untill 2025
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 5 September 2023 Resolved
Vessel is equipped with two different types of adult life jackets and only one type had donning instructions posted
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2023
Resolved 14 September 2023
Resolution: MI verified manufacturer donning instructions for both types of life jackets
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 June 2022 Resolved
No visual indicator at operating station is provided for FWD bilge. 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2022
Resolved 5 July 2022
Resolution: Deficiency rectified. All sat
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 6 June 2022 Resolved
Valve not properly secured and locked on type III MSD tank, allowing for overboard discharge. 33CFR 159.7
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2022
Resolved 5 July 2022
Resolution: Deficiency rectified. All sat
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 June 2022 Resolved
Under side of FWD escape hatch not labeled "EMERGENCY EXIT, KEEP CLEAR". 46 CFR 185.606
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2022
Resolved 5 July 2022
Resolution: Deficiency rectified. All sat
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 June 2022 Resolved
Vessels charts not up to date. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2022
Resolved 5 July 2022
Resolution: Deficiency rectified. All sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2022 Resolved
Metal electrical wiring brackets in overhead at op station not suitable, could lead to fraying of wires. 46 CFR 183.220(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2022
Resolved 5 July 2022
Resolution: Deficiency rectified. All sat
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 June 2022 Resolved
No portable light at operating station. 46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2022
Resolved 5 July 2022
Resolution: Deficiency rectified. All sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2022 Resolved
Emergency fuel shut off valves not properly labeled. 46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2022
Resolved 5 July 2022
Resolution: Deficiency rectified. All sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 6 June 2022 Resolved
Ladder up to operating station not secured. 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2022
Resolved 6 June 2022
Resolution: Secured while MI onboard
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2022 Resolved
Battery charging unit not properly mounted. 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2022
Resolved 6 June 2022
Resolution: Mounted while MI onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2022 Resolved
Life ring was not in serviceable condition. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2022
Resolved 6 June 2022
Resolution: Replaced while MI on board
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2022 Resolved
STBD engine fuel filter was not properly mounted. 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2022
Resolved 6 June 2022
Resolution: Secured while MI on board
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2022 Resolved
04 life jackets not in serviceable condition. 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2022
Resolved 6 June 2022
Resolution: Replaced while MI on board
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 6 June 2022 Resolved
Oily water mixture noted in bilge compartment. 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2022
Resolved 6 June 2022
Resolution: Cleaned while MI on board
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2022 Resolved
Leaky shaft seal on stbd shaft. 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2022
Resolved 6 June 2022
Resolution: Repaired while MI onboard
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2022 Resolved
Several open ended wiring noted in engine compartment. 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2022
Resolved 6 June 2022
Resolution: Repaired while MI onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2020 Resolved
Vessel missing coter pin on hydraulic steering ram. install cotter pin for satisfactory operation
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 11 May 2020
Resolution: Submitted picture of cotter pin installed properly.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 29 April 2020 Resolved
Vessel emergency broadcast placard has become worn and faded. Repair/replace with a durable and legible placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 1 June 2020
Resolution: recieved pictures, all sat
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 April 2020 Resolved
Vessel distress signal flare container labeling has become faded. Relabel container accordingly to make legible.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 29 April 2020
Resolution: Veseel rep relabeled container, all sat
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 April 2020 Resolved
Vessels life float paddles were starting to crack and need to be replaced with new/appropiate paddles for the life float.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 11 May 2020
Resolution: submitted pictures, all sat
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 April 2020 Resolved
Vessel did not have current publications onboard. Provide evidence of current/updated publications onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2020
Resolved 11 May 2020
Resolution: Submitted pictures of current pubs onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 October 2019 Resolved
Port side shaft penetration stuffing box leaking water. Secure stuffing box to prevent ingress of water.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2019
Resolved 29 April 2020
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 26 August 2019 Resolved
Second valve in sewage discharge line at the side shell of the vessel did not cycle. Repair or replace the overboard valve.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2019
Resolved 9 October 2019
Resolution: Sewage discharge line cycled as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 August 2019 Resolved
Vessels bilge pump visual indicator light didn't work for center void space. Repair visual indicator light fo the bilge pump in venter void
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2019
Resolved 9 October 2019
Resolution: Light was operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2019 Resolved
Port side exhuast leaking into engine space. Fix exhaust to prevent leaking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 November 2020
Resolved 29 April 2020
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 23 August 2017 Resolved
Safety certificate expired April 2017, needs new one IAW 47 CFR 80.903.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 10 October 2017
Resolution: Safety cert provided.
Stability › Watertight Integrity › General
Issued 23 August 2017 Resolved
Fiberglass repair in lazerette forward bulkhead, holes were found thru BH needs repaired IAW 46 CFR 177.360
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 10 October 2017
Resolution: Holes thru bulk head repaired.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 August 2017 Resolved
Port running light and aft mast light are not working, needs repaired IAW 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2017
Resolved 28 February 2018
Resolution: Port running light and after mast light made operable IAW 46 CFR 183.420.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 23 August 2017 Resolved
Fireboy mount is too low and chaffing fuel lines, needs to be raised off hoses IAW 46 CFR 176.800
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2017
Resolved 10 October 2017
Resolution: Fireboy bottle raised and secured.
Stability › Watertight Integrity › General
Issued 23 August 2017 Resolved
Seal starboard exhaust pipe thru bulkhead, needs sealed IAW 46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 10 October 2017
Resolution: Stbd exhaust pipe sealed at bulkhead.
Communications › Alarms/Indicators › High Water Alarm
Issued 23 August 2017 Resolved
High water horn does not work for mid and aft compartment, lights do work, repair IAW 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 28 February 2018
Resolution: High water horn made operable for mid and aft compartments.
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 August 2017 Resolved
Aft fuel tank emergency fuel shut off is not working; make work IAW 46 CFR 182.455
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2017
Resolved 10 October 2017
Resolution: Fuel shut off works properly.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 23 August 2017 Resolved
Provide current DAPI consortium letter for crew, current one expired in January. IAW 46 CFR 16.220
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 September 2017
Resolved 28 February 2018
Resolution: Current DAPI consortium letter for the crew provided IAW 46 CFR 16.220.
Stability › Watertight Integrity › General
Issued 23 August 2017 Resolved
Change both PVC pipes for submersible bilge pumps in mid and forward compartments to approved type hose IAW 46 CFR 182.520
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 10 October 2017
Resolution: PVC pipe was replaced with hose.
Construction/Loadline › Hull › Side Shell
Issued 28 June 2017 Resolved
Replace all rotten wood inboard side under the handrail. IAW 177.10-1
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 23 August 2017
Resolution: Rotten wood was replaced inboard side under hand rail.
Stability › Weathertight Integrity › General
Issued 28 June 2017 Resolved
Forward cabin emergency escape hatch needs to be operable from both sides. IAW 46 CFR 171.124
Action required: 705 - Other - as specified
Due 28 July 2017
Resolved 23 August 2017
Resolution: Cabin emergency hatch can be opened from both sides.
Construction/Loadline › Structures › Superstructure
Issued 1 March 2017 Resolved
Complete work list , replace engine room bilge pump hose, and replace all hose clamps on shaft packing gland hoses prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2017
Resolved 28 June 2017
Resolution: Verified work list complete, engine room bilge pump hose replaced, and all hose clamps on shaft packing gland hoses were repalced.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 26 May 2016 Resolved
Crewmembers not listed on DAPI letter. Ensure all crewmembers enrolled in company's drug testing program. Prior to carrying more than 6 passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2016
Resolved 15 June 2016
Resolution: Received correspondence from Owner/Operator that crewmember has been added to the vessel's consortium.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 19 May 2016 Resolved
Port Side engine inoperative. Ensure port-side engine is operational.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2016
Resolved 26 May 2016
Resolution: Replace worn wire on starter.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 19 May 2016 Resolved
Vessel not able to get underway and drills are required.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2016
Resolved 26 May 2016
Resolution: Conducted satisfactory fire, abandon ship, and man overboard drills.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 19 May 2016 Resolved
Portable fire extinguisher at operating station must be mounted and clearly visible.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 26 May 2016
Resolution: Mounted the fire extinguisher.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 May 2016 Resolved
Vessel's charts, coast pilot, light list outdated. Ensure all are current.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 22 June 2016
Resolution: Provided updated charts and pubs.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 May 2016 Resolved
Emergency instructions not posted at operating station. Post emergency instruction at operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 26 May 2016
Resolution: Posted instructions.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 19 May 2016 Resolved
Crewmembers not listed on DAPI letter. Ensure all crewmembers enrolled in company's drug testing program.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 26 May 2016
Resolution: Issued new deficiency prior to carrying over 6 passengers.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 19 May 2016 Resolved
Required EAP training and policy not provided. Provide EAP training and policy.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 22 June 2016
Resolution: Training completed with letter.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 19 May 2016 Resolved
Means of providing alcohol testing not present. Provide alcohol testing method.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 22 June 2016
Resolution: Provided alcohol strips for testing.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 19 May 2016 Resolved
Life jacket donning placards not provided for all PFD types on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 22 June 2016
Resolution: Donning placards posted.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 19 May 2016 Resolved
3 adult PFD's not serviceable. Restrict passenger carriage to 18.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 22 June 2016
Resolution: Three new life jackets purchased.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 May 2016 Resolved
Wiring and fuel vent line in salon not supported every 24 inches.
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 26 May 2016
Resolution: Installed supports.
Engineering › Bilge Water Management System › Interface Detector
Issued 19 May 2016 Resolved
High water audible alarm for aft and middle sensors inoperative.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 26 May 2016
Resolution: Fixed alarms. Worked great.
Engineering › Bilge Water Management System › Not Operational
Issued 19 May 2016 Resolved
Forward automatic bilge pump operation indicator light inoperative.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 26 May 2016
Resolution: Repaired light. Worked great.
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 October 2014 Resolved
Complete battery maintenance and install proper hardware for cable fastening.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2014
Resolved 24 November 2014
Resolution: Replaced with proper fittings.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 October 2014 Resolved
Repair 1 of 2 VHF radios and make ready for operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2014
Resolved 24 November 2014
Resolution: Repaired radio new safety cert in route.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 21 October 2014 Resolved
Replace expired hydrostatic release unit for the EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2014
Resolved 24 November 2014
Resolution: Installed new hydro release and marked.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 21 October 2014 Resolved
Repair all navigational lights and make ready for operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2014
Resolved 24 November 2014
Resolution: lights repaired and working.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 October 2014 Resolved
Replace all expired contents within the first-aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2014
Resolved 24 November 2014
Resolution: Replaced with new expired contents.
Navigation › Piloting/Steering › Marine Charts
Issued 21 October 2014 Resolved
Purchase a new or update current navigational charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2014
Resolved 24 November 2014
Resolution: Updated charts purchased.
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 October 2014 Resolved
Repair the emergency fuel pull cable for the aft STBD fuel tank and make ready for operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2014
Resolved 24 November 2014
Resolution: Fuel shut off working correctly.
Engineering › Fuel Oil Service System › Piping
Issued 21 October 2014 Resolved
Correctly install fuel lines and bulkhead penetration fittings IAW 182.720. All corrections shall be completed by the next scheduled dry-dock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2015
Resolved 11 March 2015
Resolution: Verified fuel lines and fittings were installed as required.
Personnel › Training › First Aid/CPR
Issued 25 July 2012 Resolved
Crew missing proof of training.
Due 1 October 2012
Resolved 17 September 2012
Resolution: Proof provided.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 July 2012 Resolved
Operator could not make alcohol test strips available.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2012
Resolution: Equipment provided.
Engineering › Steering Gear System › Hydraulic Hose
Issued 25 July 2012 Resolved
Steering system presents leak and ruptures that require attention to include the rudder stops and bolts.
Condition: Damaged By Earlier Event
Due 1 October 2012
Resolved 17 September 2012
Resolution: Permanent repairs witnessed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 25 July 2012 Resolved
Retro reflective material inefective on 03 lifejackets.
Condition: Improper/Lack of Maintenance
Due 1 October 2012
Resolved 17 September 2012
Resolution: Retroreflective material renewed
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 25 July 2012 Resolved
Fixed CO2 system alarm not audible.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2012
Resolution: Alarm restored.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 July 2011 Resolved
Provide original FCC station license
Due 19 August 2011
Resolved 18 August 2011
Engineering › Bilge Water Management System › Not Operational
Issued 13 July 2011 Resolved
Prove proper operation of bilge high level alarms (audible and visual), fwd bilge visible alarm not operating correctly)
Due 10 September 2011
Resolved 12 September 2011
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 13 July 2011 Resolved
Provide proper servicing certificate for pre-engineered fire system in engine room
Due 19 August 2011
Resolved 18 August 2011
Navigation › Piloting/Steering › Magnetic Compass
Issued 13 July 2011 Resolved
Provide proper illuminated magnetic compass IAW 46 CFR 184.402
Due 19 August 2011
Resolved 18 August 2011
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 23 October 2007 Resolved
Provide a current FCC Marine Radio Operator Permit as per 47 CFR 80.
Action required: 705 - Other - as specified
Due 23 November 2007
Resolved 15 November 2007
Resolution: Provided a current FCC Marine Radio Operator Permit as per 47 CFR 80.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 October 2007 Resolved
Provide a current Coast Guard Light List and Tidal Current Table as per 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 23 November 2007
Resolved 15 November 2007
Resolution: Provided a current Coast Guard Light List and Tidal Current Table as per 46 CFR 184.420.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 23 October 2007 Resolved
Provide a lifesaving maintenance record as per 46 CFR 185.720.
Action required: 705 - Other - as specified
Due 23 November 2007
Resolved 15 November 2007
Resolution: Provided a lifesaving maintenance record as per 46 CFR 185.720.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 October 2007 Resolved
Provide a Coast Guard approved First Aid Kit as per 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 23 November 2007
Resolved 15 November 2007
Resolution: Provided a Coast Guard approved First Aid Kit as per 46 CFR 184.710.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 October 2007 Resolved
Prove operation of the bilge high level alarm, in way of the visual alarm at the operating station as per 46 CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2007
Resolved 15 November 2007
Resolution: Proved operation of the bilge high level alarm, in way of the visual alarm at the operating station as per 46 CFR 182.530.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 23 October 2007 Resolved
Prove operation of the ventillation shut down for the engine room as per 46 CFR 182.465.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2007
Resolved 15 November 2007
Resolution: Proved operation of the ventillation shut down for the engine room as per 46 CFR 182.465.
Lifesaving › Hand Flares › Quantity
Issued 23 October 2007 Resolved
Provide Coast Guard approved visual distress signals as per 46 CFR 180.68.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2007
Resolved 15 November 2007
Resolution: Provided Coast Guard approved visual distress signals as per 46 CFR 180.68.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 23 October 2007 Resolved
Prove operation of the pre-engineered fire fighting system, in way of the alarms as per 46 CFR 181.420.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2007
Resolved 15 November 2007
Resolution: Proved operation of the pre-engineered fire fighting system, in way of the alarms as per 46 CFR 181.420.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 13 March 2007 Resolved
Repair and prove operation of starboard main engine raw water intake valve to the satisfaction of the attending marine inspector as per 46 CFR 182.520.
Action required: 705 - Other - as specified
Due 13 April 2007
Resolved 4 April 2007
Resolution: A new valve was installed in the raw water intake line for the starboard main engine.
Stability › Weathertight Integrity › General
Issued 13 March 2007 Resolved
Renew and prove tightness of forward emergency escape hatch to the satisfaction of the attending marine inspector in accordance with 46 CFR 177.500.
Action required: 705 - Other - as specified
Due 13 April 2007
Resolved 4 April 2007
Resolution: The emergency escape hatch was replaced.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 23 May 2006 Resolved
Provide on board vessel an up-to-date tide current and tide tables publications as required by 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 19 September 2006
Resolution: Provided an up-to-date tide current and tide tables publication.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 May 2006 Resolved
Replace one adult and three child lifejackets as required by 46 CFR 180.71, passenger count will be reduced to twenty adults and zero children until cleared by CG Marine Inspector.
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 23 May 2006
Resolution: Provided new lifejackets as required.
Fire Fighting › Fire Bucket › Availability
Issued 23 May 2006 Resolved
Provide on board vessel three 2.5 gallon fire buckets as required by 46 CFR 181.300.
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 19 September 2006
Resolution: Provided three 2.5 gallon fire buckets.
Engineering › Steering Gear System › Bracket/Clamp
Issued 23 May 2006 Resolved
Provide and install double-nut arrangement to tiller arms in the lazarette to required by 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 19 September 2006
Resolution: Double-nutted arrangement to tiller arms in the lazarette.
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 May 2006 Resolved
Label emergency fuel shut-off on the main deck accommodation space as required by 46 CFR 185.608.
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 19 September 2006
Resolution: Labeled emergency fuel shut-off on the main deck accommodation space.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 May 2006 Resolved
Adequately support electrical wiring installations to prevent overheating as required by 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 19 September 2006
Resolution: Adequately supported electrical wiring installations to prevent overheating.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 9 August 2005 Resolved
Replace retro-reflective material on lifejackets as per 46CFR185.604
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2005
Resolved 11 August 2005
Resolution: Retro replaced
Communications › Radio Communications › EPIRB
Issued 9 August 2005 Resolved
Replace expired hydrostatic release on EPIRB as per 46CFR180.64
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2005
Resolved 11 August 2005
Resolution: New release installed and found satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 August 2005 Resolved
Repair leaking wet exhaust on starboard side engine in lazarette to the satisfaction of the attending marine inspector as per 46 CFR 182.425
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2005
Resolved 11 August 2005
Resolution: Exhaust piping replaced and tested satisfactory.
Engineering › Bilge Water Management System › Piping
Issued 9 August 2005 Resolved
Connect bilge piping non-metallic hose to bilge pump in engine room with clamps as per 46 CFR 182.730.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2005
Resolved 11 August 2005
Resolution: Bilge piping double clamped.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 9 August 2005 Resolved
Repair/replace leaking MSD overboard discharge line piping as per 46 CFR 176.818.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2005
Resolved 11 August 2005
Resolution: Piping replaced.
Navigation › Piloting/Steering › US Coast Pilot
Issued 29 July 2004 Resolved
Vessel missing Coast Pilot
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 10 October 2004
Resolution: provided Coast Pilot
Engineering › Fuel Oil Service System › Hose
Issued 29 July 2004 Resolved
Provide fuel hose that meets J-1942 standard IAW 182.720 (4) (e).
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 11 March 2005
Resolution: Fuel hose meeting the J-1942 standard was provided.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 July 2004 Resolved
Prove proper operation of fixed fire fighting system IAW 181.420 (b) (3).
Action required: 705 - Other - as specified
Due 29 July 2004
Resolved 29 July 2004
Resolution: Owner proved proper operation.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 July 2004 Resolved
Provide and prove proper operation of visual indicator for bilge high level alarm IAW 182.530 (a).
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 July 2004
Resolved 29 July 2004
Resolution: Owner proved proper operation.
Documentation › Logs/Records
Issued 8 July 2003 Resolved
Provide current training logbook & bridge log IAW 46 CFR 185.420 & 46 CFR 185.702.
Due 8 August 2003
Resolved 12 September 2003
Resolution: Owner/Operator provided copies of log books.
Engineering › Fuel Oil Service System
Issued 8 July 2003 Resolved
Replace plastic fitting on the bottom of the fuel filters with a metal fitting & a cap. LEGACY COMPONENT DESC: Filter
Due 8 August 2003
Resolved 12 September 2003
Resolution: Owner replaced the plastic fittings with metallic fittings.
Engineering › Fuel Oil Service System
Issued 21 March 2003 Resolved
Repair or replace fuel shutoff valves and prove opeartional in accordance with 46 CFR 182.455(b). LEGACY COMPONENT DESC: Valve, Control
Due 21 April 2003
Resolved 10 April 2003
Resolution: Emergency fuel shutoff repaired and made more functional.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 March 2003 Resolved
Replace exhaust clamps and support brackets on both wet exhaust pipes as per 46 CFR 812.430. LEGACY COMPONENT DESC: Piping (exhaust)
Due 21 April 2003
Resolved 10 April 2003
Resolution: Clamps & support brackets replaced.
Engineering › Steering Gear System
Issued 21 March 2003 Resolved
Provide double nuts for steering system jockey bar assembly connection. LEGACY COMPONENT DESC: Fastener
Due 21 March 2003
Resolved 21 March 2003
Resolution: Corrected during inspection.
Accommodation/Occupational Safety
Issued 16 May 2001 Resolved
REPLACE GASKET ON E/R VENTS AS REQUIRED BY 46 CFR 182.530
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Construction/Loadline
Issued 16 May 2001 Resolved
PROVIDE HIGH BILGE ALARM ON BRIDGE AS REQUIRED BY 46 CFR 182.530
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Electrical
Issued 16 May 2001 Resolved
PROVIDE BATTERY COVER AS REQUIRED BY 46 176.806
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Documentation
Issued 16 May 2001 Resolved
PROVIDE FCC SAFETY CERTIFICATE AS REQUIRED BY 47 CFR 80
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Navigation
Issued 16 May 2001 Resolved
PROVIDE UPDATED CHARTS AND PUBLICATIONS AS REQUIRED BY 46 CFR 184.420
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Lifesaving
Issued 16 May 2001 Resolved
PROVIDE PUBLIC ADDRESS SYSTEM AS REQUIRED BY 46 CFR 184.610
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Construction/Loadline
Issued 16 May 2001 Resolved
MAKE ENGINE ROOM VAPOR TIGHT AS REQUIRED BY 46 CFR 176.810(A)
Condition: Unknown
Due 16 May 2001
Resolved 16 May 2001
Engineering
Issued 16 March 1999 Resolved
RENEW FLEX HOSE OIL LINES ON STARBOARD ENGINE.
Condition: Unknown
Due 23 April 1999
Resolved 27 July 1999
Navigation
Issued 16 March 1999 Resolved
RENEW HYDRAULIC FITTINGS ON STEERING RAM.
Condition: Unknown
Due 23 April 1999
Resolved 27 July 1999
Construction/Loadline
Issued 16 March 1999 Resolved
PROVIDE AND INSTALL AN ADDITIONAL HIGH LEVEL ALARM SWITCH IN THE LAZARETT.
Condition: Unknown
Due 23 April 1999
Resolved 27 July 1999
Lifesaving
Issued 17 March 1998 Resolved
DEMONSTRATE ABANDON SHIP AND MAN OVERBOARD DRILLS AS PER 46 CFR 176.808(A).
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Navigation
Issued 17 March 1998 Resolved
POST NEW EMERGENCY BROADCAST PLACARD AS PER 46 CFR 184.506.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Lifesaving
Issued 17 March 1998 Resolved
PROVIDE VALID RED CROSS FIRST AID/CPR CARDS FOR 50% OF THE CREW. NVIC 1-91.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Lifesaving
Issued 17 March 1998 Resolved
RENEW RETROREFLECTIVE TAPE ON LIFEFLOAT AS PER 46 CFR 160.027.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Lifesaving
Issued 17 March 1998 Resolved
RENEW ONE ADULT TYPE I PFD AS PER 46 CFR 180.71(A).
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Electrical
Issued 24 March 1995 Resolved
STRAP ELECTICAL WIRING IN OVERHEAD OF THE MACHINERY SPACE, OUTBOARD THE PROPULSION ENGINES WITH A METALLIC STYLE WIRE TIE VS. NYLON WIRE TIES.
Condition: Unknown
Due 24 April 1995
Resolved 8 June 1995
Engineering
Issued 24 March 1995 Resolved
REPAIR AND STOP FUEL LEAK NOTED ON THE STBD ENGINE, SECONDARY FUEL FILTER TUBING FITTING.
Condition: Unknown
Due 24 April 1995
Resolved 8 June 1995
Lifesaving
Issued 24 March 1995 Resolved
POST VESSEL'S "EMERGENCY CHECK LIST" AS REQUIRED BY 46 CFR 185.25 IN A LOCATION THAT IS VISABLE TO ALL PASSENGERS AND CREWMEMBERS.
Condition: Unknown
Due 24 April 1995
Resolved 8 June 1995
Lifesaving
Issued 24 March 1995 Resolved
PROVIDE ONBOARD VESSEL, COPY OF REGULATIONS FOR CLASS OF VESSEL _x001C_ (SUBCHAPTER-T)
Condition: Unknown
Due 24 April 1995
Resolved 8 June 1995
Navigation
Issued 24 March 1995 Resolved
PROVIDE VESSEL WITH REQUIRED DAYSHAPES (2 BLACK BALLS) AS PER 72 CLOREGS, (33 CFR PART 81)
Condition: Unknown
Due 24 April 1995
Resolved 8 June 1995
Documentation
Issued 24 March 1995 Resolved
PROVIDE PROOF OF ENROLLMENT IN AN ACCEPTABLE RANDOM DRUG TESTING PROGRAM ASREQUIRED BY 46 CFR 16. PROOF TO BE PROVIDED PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 24 April 1995
Resolved 8 June 1995
Accommodation/Occupational Safety
Issued 24 March 1995 Resolved
CHAIN/LOCK THE MSD OVERBOARD DISCHARGE AND MARK "KEEP CLOSED WHEN WITHIN 3 MILES OF SHORE".
Condition: Unknown
Due 24 April 1995
Resolved 8 June 1995