Records from 2016 to 2026. Most recent: inspection, 23 April 2026.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 13.4 ft × 2.5 ft
Registered tonnagegross 5 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJOHN K OWENS · WINTER SPRINGS, FL, UNITED STATES · built 1994
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTri Hull
Hailing portMURRELLS INLET, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
23 April 2026
COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8349422
13 June 2025
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8161904
17 July 2024
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7960656
17 January 2024
Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7850576
3 August 2023
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7759707
9 August 2022
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7529055
27 August 2021
Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7298079
12 May 2021
COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7185577
7 January 2021
Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7134078
13 August 2020
Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7018413
12 August 2019
Deficiency Check · Annual Inspection · DAPI Audit · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6781982
6 January 2019
Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6607423
14 August 2018
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6496375
14 August 2017
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6241135
12 August 2016
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5970280
16 May 2016
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5879289
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 January 2021
Resolved
Any vessel of at least five net tons which engages in Coastwise Trade must have a Certificate of Documentation. Vessel is currently registered with the State of South Carolina. Based on vessels net tonnage, the vessel is required to be federally documented with the U.S. Coast Guard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2021
Resolution: Vessel has been issued a current/valid Certificate of Documentation (COD).
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 January 2021
Resolved
Any vessel that engages in unrestricted coastwise trade is required to possess a coastwise endorsement on its Certificate of Documentation (COD). The vessel meets the definition of coastwise trade and is required to possess a valid coastwise endorsement on its COD.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2021
Resolution: Vessel has been issued a valid/current Certificate of Documentation (COD) with proper endorsements.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 January 2021
Resolved
The official number of a vessel must be preceded by the abbreviation "NO" and must be marked in block arabic numerals not less than 3" in height on an interior structural part of the vessels hull. Once assigned, the official number shall be marked as described above.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 January 2021
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port & starboard bow and the stern of the vessel. The haling port must be marked on some clearly visible exterior part of the stern of the vessel. Vessels name & hailing port markings shall be verified.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2020
Resolved
Where flexibility is necessary or desired, a reasonable length of flexible hose may be used for gasoline fuel supply piping. Existing flexible fuel supply piping is (UV) deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2020
Resolved 31 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 August 2020
Resolved
Vessel required to carry a serviceable ring life buoy on board. Existing ring life buoy grab line is (UV) deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2020
Resolved 31 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 August 2020
Resolved
Vessel required to be equipped with a first aid kit suitable for vessels operations. Expired items noted IWO existing first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2020
Resolved 31 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 August 2019
Resolved
Vessel was not equipped with proper type/qty of visual distress signals (expired).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 August 2019
Resolved 23 August 2019
Resolution: Verified carriage of proper type/qty of VDS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2019
Resolved
Brackets for portable fire extinguishers IWO operators console/helm were wasted/required replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 23 August 2019
Resolution: Verified renewal of portable fire extinguisher brackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 August 2019
Resolved
PFD markings were worn/missing on five adult Type I PFD's.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 23 August 2019
Resolution: Verified renewal of PFD markings for Type I PFD's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2019
Resolved
Retro-reflective markings worn on ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 23 August 2019
Resolution: Verified retro-reflective markngs for ring life buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 August 2019
Resolved
Starboard aft battery box not properly secured/mounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2019
Resolved 23 August 2019
Resolution: Verified securing of stbd battery box.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 August 2018
Resolved
Renew worn Type I PFDs (adult/child)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2018
Resolved 7 November 2018
Resolution: Attending Inspector(s) verified carriage of proper type/qty of PFD's.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 August 2018
Resolved
Tighten peripheral railings
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2018
Resolved 7 November 2018
Resolution: Attending Inspector(s) verified repairs/adjustments made to peripheral railings.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 14 August 2017
Resolved
Missing one hand portable B:C I extinguisher at/near operating station.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified installation of B:C I fire extinguisher at the operating station.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 August 2017
Resolved
Mast head light was inoperable at time of inspection (blown bulb)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified operation of mast head light.
Documentation › Markings/Placards › Warning Signs
Issued 14 August 2017
Resolved
Emergency escapes were not marked properly.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified posting of emergency escape markings.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 August 2017
Resolved
Ring life buoy not equipped with proper type/length of line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified installation of proper type/lenght of line for ring life buoy.
Electrical › Electrical Distribution System (service) › Conductor
Issued 14 August 2017
Resolved
Electrical conductors under helm were not properly terminated (dead ended).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified removal/termination of electrical conductors @ helm.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 14 August 2017
Resolved
Installed marine sanitation device (Type III) was inoperable at the time of the inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified the removal of Type III MSD (toilet).
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 14 August 2017
Resolved
Installed gasoline fuel tanks were not tested/inspected prior to being placed into service.
Action required: 705 - Other - as specified
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified removal of exsiting (aluminum) fuel tanks and verified the installation of new plastic fuel tanks that meet ABYC H-25.