Records from 2011 to 2026. Most recent: inspection, 29 May 2026.
Inspection history · 21
29 May 2026
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8377322
19 December 2025
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8284587
18 July 2025
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8188768
4 February 2025
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8075292
22 October 2024
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8035295
23 May 2024
Drydock Exam · Deficiency Check · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8033697
18 March 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7879526
21 February 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7639293
19 October 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7577178
10 March 2022
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7546943
9 February 2022
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7390758
4 January 2021
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7117280
27 October 2020
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7079913
25 March 2020
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6925884
25 March 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6645407
16 October 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6562580
30 July 2018
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6495189
1 March 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6381812
30 October 2017
Administrative Inspection · Hull Examination · Deficiency Check · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6323871
25 October 2016
Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6030339
4 January 2016
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5790196
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 November 2024
Resolved
Identified broken strands in the mizzen mast backstays. Replace backstays in kind or prove new stays have equal or greater safe working load and breaking strength.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2024
Resolved 26 November 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 November 2024
Resolved
Update rigging inventory with new mizzen mast backstay installation dates.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2024
Resolved 26 November 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 March 2024
Resolved
Provide a 2-A portable fire extinguisher in the main cabin passenger accommodation space to meet COI equipment requirements.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 February 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Resolved 9 February 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 February 2022
Resolved
Provide 4 additional hand red flare distress signals to make a total of 12 hand red flares on board.
Action required: 10 - Deficiency Rectified
Resolved 9 February 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 February 2022
Resolved
Provide a first-aid kit or its equivalent contents and instructions.
Action required: 10 - Deficiency Rectified
Resolved 9 February 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 February 2022
Resolved
Display or distribute a community service hot-line telephone number for crewmembers seeking assistance with drug and alcohol abuse.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 February 2022
Resolved
Provide and document drug and alcohol use training for all crewmembers as part of the company's required Employee Assistance Program.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 March 2022
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 9 February 2022
Resolved
Did not get the vessel underway during this Annual Inspection due to in climate weather. Vessel's crew must conduct a man overboard drill within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 October 2020
Resolved
Replace missing thru hull fitting for starboard water tank vent.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 October 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 October 2020
Resolved
Grind and renew scratched/blistered fiberglass as identified on hull exterior.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 October 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 October 2020
Resolved
Interior starboard chain plate for main mast shrouds is showing evidence of cracks. Remove interior/exterior chain plates and make available for inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2020
Resolution: Chain plate replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 October 2020
Resolved
Clean interior/exterior port chain plates for main mast shrouds to identify if surface rust is evidence of cracks.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 October 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 October 2020
Resolved
The deck fittings for the mizzen back stay rail are loose. Tighten bolts or add backing support as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 October 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 March 2020
Resolved
Demonstrate proper operation of high water alarm audible indicator for engine room space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2020
Resolution: alram replaced, operational
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 March 2020
Resolved
Provide a total of 12 distress signals (12 hand-held red flares or 6 hand-held red and 6 hand-held orange smoke)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2020
Resolution: All required flares on board
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 March 2019
Resolved
Vessel must provide ventilation duct for engine room and ventilation covers that can be secured to contain Fireboy agent, covers must be readily available and mounted in the vicinity. Provide plan before install.
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 1 April 2019
Resolution: Ventalation located, ventalation shutdowns are installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 March 2019
Resolved
Replace Ring buoy, floating waterlight and lanyard.
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 1 April 2019
Resolution: New ring buoy and waterlight provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2019
Resolved
Provide physical means to sound each fuel tank by use of fuel gauge, sounding pipe or sight glass.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 April 2019
Resolution: Yard stick provided and access confirmed for both tanks.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 March 2019
Resolved
Post sign at operating station "Offical Documents available upon request". 1 inch letters
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2019
Resolution: Sign posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 March 2019
Resolved
PFD donning placard must be provided for each type of PFD. Current placard does not match PFD type.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2019
Resolution: Donning placard posted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 March 2019
Resolved
Provide printed upto date publications (Coast Pilot [name withheld], tides and currents) for area of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2019
Resolution: Publications on board.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 25 March 2019
Resolved
VHF radio must have GPS input to transmit in the event of an emergency.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 April 2019
Resolution: VHF radio has GPS connected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2019
Resolved
Cover battery terminals to prevent arcing if object fell ontop.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 April 2019
Resolution: Boots provided to all terminal posts.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 March 2019
Resolved
Add gaskets to E/R deck boards to prevent escape of Fireboy agent.
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 1 April 2019
Resolution: Gaskets added to both deck hatches.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2019
Resolved
Cap dead-ended wire at operating station or remove wire.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2019
Resolution: Dead-end wire capped.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 17 October 2018
Resolved
Make available a Rigging Preventative Maintenance Program that provides a level of detail commensurate with Appendix (2) to Enclosure (1) of NVIC 02-16 (Rigging Inventory/Preventative Maintenance Inspection Template (Sample)) or propose a mutually acceptable third party to survey the rigging and provide a report with a level of detailed commensurate with either Appendix (3) or (4) to Enclosure (1) of NVIC 02-16 (Third Party Rigging Survey Samples A&B).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 January 2019
Resolution: PMP received.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 October 2018
Resolved
Grind down to good glass on all indicated areas on hull. Make ready for inspection prior to conducting any FRP repairs.
Action required: 705 - Other - as specified
Resolved 31 October 2018
Resolution: All areas ground down to good glass and repaired with original layup schedule.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2018
Resolved
Replace cutlass bearing, bearing wore past 50%.
Action required: 705 - Other - as specified
Resolved 31 October 2018
Resolution: Cutlass replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2018
Resolved
Repair FRP rudder and aft keel per layup schedule, hole identified in bottom of rudder than allowed water intrusion.
Action required: 705 - Other - as specified
Resolved 31 October 2018
Resolution: Rudder repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 October 2018
Resolved
Replace Port forward chain plate fastener with properly sized chain plate fastener. 3rd fastener from top found protruding out from chain plate, without a locking nut on back. Fastener length was to long for installation.
Action required: 705 - Other - as specified
Resolved 31 October 2018
Resolution: New fastener inserted and seated.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 17 October 2018
Resolved
Repair backing wood/plate on ground tackle winch, wood and FRP was wasted under winch mounting location.
Action required: 705 - Other - as specified
Resolved 8 January 2019
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 17 October 2018
Resolved
Repair/replace engine room transver wood frame in engine room by way of shaft.
Action required: 705 - Other - as specified
Resolved 8 January 2019
Resolution: Frame repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 October 2018
Resolved
Conduct underway operational test of sailing rig under full sail per approved sail plan in the presence of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 November 2018
Resolution: Conducted satisfactory underway sail.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 March 2018
Resolved
Found 05 unservicable adult PFDs, reduced passenger count until replaced.
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 2 March 2018
Resolution: PFDs replaced.
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 March 2018
Resolved
Vessel did not have donning placard for each type of lifejacket on board.
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 2 March 2018
Resolution: placard posted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 1 March 2018
Resolved
Missing B-1 (10BC) fire extinguisher at operating station.
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 2 March 2018
Resolution: Fire extinguisher mounted
Communications › Radio Communications › EPIRB
Issued 1 March 2018
Resolved
Epirb hydrostatic release expired
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 2 March 2018
Resolution: Hydrostatic release replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 March 2018
Resolved
No bouyant lifeline attached to ring buoy.
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 2 March 2018
Resolution: Lifeline Installed
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 1 March 2018
Resolved
FCC Safety certificate expired
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 2 March 2018
Resolution: New certificate issued
Electrical › Electric Supply System (service) › Cable
Issued 30 October 2017
Resolved
Remove all damaged electrical wire and equipment in engine room and renew in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Resolution: Renewed all damaged cable and removed obsolete Balmar equipment.
Sail Rigging › Spars › Boom and Gooseneck Fitting
Issued 30 October 2017
Resolved
Renew main mast boom vang prior to using main sheet.
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 11 November 2017
Resolution: Vessel installed new boom vang.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 17 January 2017
Resolved
Renew 02 adult size PFD's. Vessel restricted to carriage of 29 passengers.
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 17 January 2017
Resolution: 02 PFD's replaced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 October 2016
Resolved
Make repairs to rails to meet 4 inch course or netting requirement. Submit plans to OCMI for approval prior to making repairs.
Action required: 705 - Other - as specified
Due 25 November 2016
Resolved 17 January 2017
Resolution: Vessel installed line on stanchions in a netting fashion. Installation meets requirements.
Lifesaving › Hand Flares › Quantity
Issued 4 January 2016
Resolved
Vessel had only 8 of required 12 flares on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 11 January 2016
Resolution: Flares were added to the vessel to total 12
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 January 2016
Resolved
Vessel did not have first aid kit meeting 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 11 January 2016
Resolution: First aid kit added
Documentation › Logs/Records › Drug Test Records
Issued 4 January 2016
Resolved
Vessel does not have adequate random drug testing program in place. Owner/Operator instructed to implement proper method of conducting random drug testing program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 11 January 2016
Resolution: Company implemented random drug testing program
Fire Fighting › Fire Bucket › Quantity
Issued 4 January 2016
Resolved
Vessel only had 1 of the required 3 fire buckets on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 11 January 2016
Resolution: 02 fire buckets added