Records from 2016 to 2026. Most recent: inspection, 27 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 19.0 ft × 7.6 ft
Registered tonnagegross 58 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRESMONDO BOAT WORKS · PERDIDO BEACH, AL, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 14 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Simplified, Gross Ton
46 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
26 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 26
27 May 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8377741
11 March 2025
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8084444
11 February 2025
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8078105
13 May 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7911374
7 November 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7822525
25 May 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7695700
28 February 2023
Hull Examination · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7634785
3 February 2023
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7631808
18 January 2023
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7629828
3 May 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7442735
14 September 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7317457
29 March 2021
Administrative Inspection · Examination of Repairs · Drydock Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7164811
25 March 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7162523
25 February 2021
Drydock Extension · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7148695
9 October 2020
Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7074579
5 October 2020
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7071812
16 September 2020
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7076104
27 January 2020
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6896803
18 September 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814717
5 February 2019
Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6620149
5 February 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6620186
23 February 2018
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6360624
17 April 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6126690
24 February 2017
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6094139
2 February 2017
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6081850
4 March 2016
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5827225
02 - Structural Conditions › N/A - No Subsystem › Damage control plan
Issued 9 October 2020
Resolved
Issued 835V stating no repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met. The procedures to be followed in notifying the Coast Guard about vessel repairs vary according to the type of vessel and service in which engaged. Vessel owner/operator notified CG that the vessel suffered damage due to Hurricane Sally in accordance with applicable regulatory cite. Vessel must make permanent repair/alteration to the satisfaction of the OCMI in accordance with 46 CFR 176.700(a).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2021
Resolution: Conducted u/w test of machinery, evaluated hull condition post hurricane sally to satisfaction of MI.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 12 March 2020
Resolved
MMSI number on FCC certificate is not programmed into the radio installations. ensure that MMSI number on FCC certificate is satisfactorily programmed into radio installations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 23 March 2020
Resolution: MMSI number on FCC certificate verified to be programmed into the radio installation.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 March 2020
Resolved
Smoke detecting units did not meet UL 217 or other specified standards. Replace 03 detectors with approved type either stating UL 217 or suitable for use in recreational vehicles.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 23 March 2020
Resolution: 03 Smoke detectors replaced with approved type.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 March 2020
Resolved
Emergency lighting did not adequately illuminate escape route from below the main deck. Replace with emergency lighting that will adequately and automatically activate during a loss of power.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2020
Resolved 23 March 2020
Resolution: Emergency lighting was replaced and demonstrated to adequately and automatically activate during a loss of power.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 March 2018
Resolved
Fireboy manual activation missing, prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2018
Lifesaving › Lifefloat › Painter
Issued 13 March 2018
Resolved
Line connecting life floats not long enough, provide correct length of line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 19 March 2018
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 March 2018
Resolved
Charts not up to date, provide chart corrections for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 19 March 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 13 March 2018
Resolved
Manual activation for vent closures in engine room disconnected, prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 19 March 2018
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 March 2018
Resolved
DAPI letter not on-board, provide letter with list of employees.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 19 March 2018
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 23 March 2017
Resolved
Provide training and consortium policy for vessel and crew members.
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 17 April 2017
Resolution: Certificate of completion was issued.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 23 March 2017
Resolved
Emergency instructions posted at operating station, for vessels drills.
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 17 April 2017
Resolution: Instructions posted at operating station.
Communications › Alarms/Indicators › High Water Alarm
Issued 23 March 2017
Resolved
High water alarm sounds but no visual, make repairs as needed.
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 17 April 2017
Resolution: High water alarm was working properly.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 March 2017
Resolved
Forward white light not working, make repairs as needed.
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 17 April 2017
Resolution: FWD white light was working.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 23 March 2017
Resolved
Provide ladder for man overboard, a safe means for someone to get back on board.
Action required: 705 - Other - as specified
Due 23 July 2017
Resolved 17 April 2017
Resolution: Ladder for man overboard drills was purchased and on board.
Communications › Public Address System › Amplifier
Issued 23 March 2017
Resolved
PA system needs to be heard from accommodation spaces when doors are shut.
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 17 April 2017
Resolution: New speaker installed and tested.
Deck/Cargo › Cargo Stowage › General
Issued 21 February 2017
Resolved
Valve to ice chest drain did not operate correctly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 17 April 2017
Resolution: Valve was replaced and worked properly.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 March 2016
Resolved
46 CFR 16.401: The EAP training program must include documentation of training given to crew members and the employers supervisory personnel. Provide documentation of required training program.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 12 April 2016
Resolution: Provided evidence of EAP training for crew and supervisors.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 March 2016
Resolved
46 CFR 177.960: An exposed hazard, such as gears or rotating machinery must be properly protected by a cover, guard, or rail. Replace missing guard on generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 12 April 2016
Resolution: Reinstalled cover on generator.