Records from 1994 to 2011. Most recent: inspection, 15 July 2011.
Inspection history · 45
15 July 2011
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4080102
5 October 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2794507
28 June 2006
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2694938
23 June 2006
Deficiency Check · MARPOL Annex V Examination · MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2689010
25 May 2006
MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2658535
24 May 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2657871
23 May 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2655783
14 March 2006
MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2602265
9 February 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2582211
4 January 2006
MARPOL Annex I Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2560681
28 November 2005
MARPOL Annex I Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2541620
14 October 2005
PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2514775
10 August 2005
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2458376
5 August 2005
PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2452572
2 July 2005
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2411321
24 May 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2367210
16 May 2005
PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2358282
16 May 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2361380
7 April 2005
PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2323903
12 March 2005
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2308601
19 October 2004
Random ISPS/MTSA/PSC
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2224227
2 August 2004
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2254538
16 July 2004
ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2136012
15 May 2004
Annual Inspection · MTSA/ISPS Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2069136
25 October 2003
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1933699
21 July 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1852964
20 March 2003
MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1754436
2 April 2002
In-Service Inspection · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1600683
23 October 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 294921
2 March 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 287657
23 January 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 286322
26 March 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 276214
10 February 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 425346
30 January 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 425034
18 July 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 418166
7 March 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 413502
22 February 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 400739
8 September 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 395051
3 August 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 71456
11 December 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 385693
15 January 1995
Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1152993
13 January 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 36660
7 December 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 373189
7 December 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141694
3 July 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 368280
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 13 July 2011
Resolved
74SOLAS (97 CONS) II-1/44.2- Each emergency generating set arranged to be automatically started shall be equipped with a second source of energy provided for additional three starts within 30 minutes. PSCO found that the secondary means for starting (air start) for the emergency generator was inoperable. Corrected on the spot.
Due 15 July 2011
Resolved 15 July 2011
Resolution: Vessel corrected deficiency on the spot.
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 13 July 2011
Resolved
74SOLAS (09 CONS) III/20.2- Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel's rescue boat engine is not operational. Corrected on the spot.
Due 15 July 2011
Resolved 15 July 2011
Resolution: Vessel corrected deficiency on the spot.
Engineering › Diesel Engine (propulsion-direct drive) › Piston
Issued 24 May 2005
Resolved
Vessel lost main propulsion. Vessel must have class society (Lloyd's Registry) determine the cause of the failure and send a report to USCG.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2005
Resolution: Vessel''s class society determined the cause of the propulsion failure and sent a report to USCG.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 16 May 2005
Resolved
Unauthorized bypass fittings identified onboard to connect sludge pump deirectly to overboard discharge valve from oily-water separator. Oil residue found in all related pipes.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2005
Resolved 14 October 2005
Resolution: Vessel was found to be in compliance.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 16 May 2005
Resolved
Unauthorized bypass hoses and pump identified to pump directly from oily-water tank to overboard discharge valve from oily-water separator. Oil residue found in all related hoses and in pump.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2005
Resolved 14 October 2005
Resolution: Vessel was found to be in compliance.
Documentation › Logs/Records › Oil Record Book
Issued 16 May 2005
Resolved
Improper entries found in oil record book. Improper codes used and alterations found.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2005
Resolution: Vessel was found to be in compliance.
Documentation › Logs/Records › Oil Record Book
Issued 16 May 2005
Resolved
Oil record book not retained onboard for past three years. Only last six months onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2005
Resolution: Vessel was found to be in compliance.
Fire Fighting
Issued 30 January 1999
Resolved
The portable fire extinguishers have not been examined since August of 1997. Must provide portable fire extinguisher sevicing certificate or proof of flag state (MX) requirements allowing examination intervals beyond1 year NLT 02 Mar 99. SOLAS 74/II-2 reg 6/5.
Condition: Unknown
Due 10 February 1999
Resolved 10 February 1999
Deck/Cargo
Issued 3 July 1994
Resolved
ONE 40' CONTAINER WITH CORROSIVIES WAS MISSING THE PLACARD FROM THE FORWARDEND
Condition: Unknown
Due 3 July 1994
Resolved 6 July 1994
Navigation
Issued 3 July 1994
Resolved
VESSEL DID NOT HAVE A TABLE OF SPEEDS AT WHICH THE BOW THRUSTER IS EFFECTIVE
Condition: Unknown
Due 3 July 1994
Resolved 6 July 1994
Documentation
Issued 3 July 1994
Resolved
VESSEL DID NOT HAVE A VALID C.O.F.R. ONBOARD
Condition: Unknown
Due 3 July 1994
Resolved 6 July 1994