MAURY USCG vessel records
← All vessels

OCC 1104

Built
1965
Last inspected
21 March 1997
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 21 March 1997
…with no type recorded23
Operational controls None recorded without a removal date
Years with a record 16 calendar years (1982–1997)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
693 - Regulatory (Subpart C or D), Net Ton 693 - Regulatory (Subpart C or D), Gross Ton
Maury page id
psix-40835
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 43

21 March 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1104125
17 March 1997 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1095063
8 November 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414710
9 November 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448703
19 October 1995 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1449867
21 October 1994 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 867920
4 November 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1157653
19 October 1993 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1415902
24 August 1993 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 507927
12 December 1992 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1246933
30 September 1992 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1261756
10 September 1992 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 943134
10 September 1992 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1254620
21 January 1992 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 455533
12 September 1991 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 492138
30 August 1991 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1245857
19 June 1991 Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1250262
10 June 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 512716
6 March 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 530224
4 December 1990 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 536437
13 September 1990 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1211917
20 February 1990 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 473239
27 September 1989 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1313102
18 September 1989 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 494570
24 May 1989 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 454188
31 January 1989 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 521400
9 September 1988 COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1044483
29 July 1988 Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1044482
1 June 1988 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 489461
12 June 1987 Type not recorded
No type recorded · MSO NASHVILLE · Activity 523308
13 May 1987 Hull Examination · COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1027559
10 September 1986 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 535815
17 June 1986 COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 997002
25 April 1986 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1307362
1 May 1985 Type not recorded
No type recorded · MSO NASHVILLE · Activity 301803
1 May 1985 Type not recorded
No type recorded · MSO NASHVILLE · Activity 980347
14 January 1985 Type not recorded
No type recorded · MSO NASHVILLE · Activity 486995
27 September 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 974465
17 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974491
25 April 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 974176
30 January 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 971468
25 February 1983 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 972050
8 April 1982 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1272661

Deficiency record · 25

Construction/Loadline
Issued 21 March 1997 Resolved
EFFECT PERMANENT REPAIRS TO 18 INCH FRACTURE IN STBD BOW 2 FEET DOWN FROM DECK AND 4 FEET AFT OF BOW. CARGO NOT TO BE LOADED UNTIL REPAIRS ARE COMPLETED AND APPROVED BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 21 April 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 8 November 1996 Resolved
CONDUCT SAFETY VALVE INSPECTION IN ACCORDANCE WITH 46 CFR 151.04-5(i).
Condition: Unknown
Due 7 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 8 November 1996 Resolved
CONDUCT CARGO TANK HYDRO TEST IN ACCORDANCE WITH 46 CFR 151.50-31 (p).
Condition: Unknown
Due 7 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 8 November 1996 Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION AS REQUIRED BY 46 CFR 67.7.
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 8 November 1996 Resolved
CONDUCT CARGO TANK INTERNAL EXAM IN ACCORDANCE WITH 46 CFR TABLE 151.05.
Condition: Unknown
Due 7 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 10 September 1992 Resolved
RENEW THE GASKET MATERIAL ON THE FORWARD RAKE COMPARTMENTS ACCESS COVER.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Deck/Cargo
Issued 10 September 1992 Resolved
AT THE NEXT YARD AVAILABILITY RENEW/REPAIR ALL CARGO TANK SADDLE BRACKETS WHERE WASTED.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Deck/Cargo
Issued 10 September 1992 Resolved
CARGO TRANSFER PIPING AND AIR CHARGE PIPING ARE TO BE MOUNTED INTO SADDLE BLOCKS OR SIMILIAR SUPPORTING METHOD.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Deck/Cargo
Issued 10 September 1992 Resolved
CLEAN OUT BOTH OF THE BARGE HOPPER SPACES OF COLLECTED WATER AND DISCARDED MATERIALS. ALL EIGHT BILGE SUCTION POCKETS ARE ALSO TO BE CLEANED.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Deck/Cargo
Issued 10 September 1992 Resolved
RENEW/REPAIR THE COLLARS THAT ARE WASTED WHERE THE CARGO TANK HOLD DOWN BANDS PASS THROUGH THE SADDLE SUPPORT FLANGES.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Construction/Loadline
Issued 10 September 1992 Resolved
TIGHTEN DOWN THE AFT PLATFORM HOLD DOWN BRACKETS WHERE THE TIE DOWN FASTENERS (BOLTS/NUTS), HAVE COME LOOSE.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Deck/Cargo
Issued 10 September 1992 Resolved
MARK THE CARGO TANKS FOR TANK IDENTIFICATION (#1 THRU #4).
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Construction/Loadline
Issued 10 September 1992 Resolved
IN AREAS OF THE WING VOIDS AIR TEST DECK PENETRATIONS, SCALE OFF RUST AND APPLY A PROTECTIVE PAINT COATING.
Condition: Unknown
Due 10 September 1992
Resolved 10 September 1992
Unknown
Issued 9 September 1988 Resolved
MAKE PERMENANT REAPIRS, TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR TO A 2' FRACTURE STBD SIDE AMIDSHIPS AT DECK KNUCKLE. REPAIRS ARE TO BE PERMENANT IN NATURE AND COMPLETED PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Unknown
Issued 9 September 1988 Resolved
PUMP WATER FROM HOPPER AND MAKE AVAILABLE TO U.S. COAST GUARD MARINE INSPECTOR FOR INSPECTION. THIS REQUIREMENT TO BE ACCOMPLISHED PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Unknown
Issued 9 September 1988 Resolved
GAS FREE AND PROVIDE A GAS FREE CERTIFICATE FOR THE CARGO CYLINDERS ABOARD TANK BARGE DSC 1104 TO ACCOMPLISH A CARGO TANK INTERNAL INSPECTION. THIS REQUIREMENT TO BE ACCOMPLISHED PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Construction/Loadline
Issued 25 April 1986 Resolved
VESSEL DUE FOR DRYDOCK INSPECTION. PRESENT VESSEL FOR A DRYDOCK INSPECTION.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Deck/Cargo
Issued 25 April 1986 Resolved
CARGO TANKS NOT INTERNALLY INSPECTED. PRESENT CARGO TANKS FOR AN INTERNAL INSPECTION.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Construction/Loadline
Issued 25 April 1986 Resolved
PORT STERN TIMBERHEAD TORN LOOSE FROM DECK. MAKE PERMANENT REPAIRS TO THE PORT STERN TIMBERHEAD AND HOLED DECK.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Deck/Cargo
Issued 25 April 1986 Resolved
CARGO PIPING NOT TESTED. TEST CARGO TRANSFER PIPING SYSTEM AT 1-1/2 TIMES MAWP.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Deck/Cargo
Issued 25 April 1986 Resolved
CARGO TANKS NOT TESTED. TEST CARGO TANKS AT 450 PSI.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Deck/Cargo
Issued 25 April 1986 Resolved
SAFETY VALVES NOT TESTED. REMOVE AND BENCH TEST THE SAFETY RELIEF VALVES.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Unknown
Issued 17 August 1984 Resolved
MAINTAIN TEMPORARY EMERGENCY REPAIR KIT APPLIED TO SAFETY RELIEF VALVE IN WAY OF #2 PORT CARGO TANK DOME.
Condition: Unknown
Due 17 August 1984
Resolved 17 August 1984
Unknown
Issued 17 August 1984 Resolved
VESSEL IS TO PROCEED TO HOUSTON TX. TO OFF-LOAD PRESENT CARGO AND MAKE PERMANENT REPAIRS PRIOR TO LOADING NEXT CARGO.
Condition: Unknown
Due 17 August 1984
Resolved 17 August 1984
Unknown
Issued 17 August 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE T/B D.S.C 1104, O.N. 005132 AND ARE TO BE COMPLIED BY 17SEP84.
Condition: Unknown
Due 17 August 1984
Resolved 17 August 1984

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.