ALBATROS

ALBATROS is a 1988 freight ship. The Coast Guard has recorded 15 inspections since 1997, most recently in December 2004, along with 7 deficiencies and 1 operational control.

Records from 1997 to 2004. Most recent: operational control imposed, 2 December 2004.

Built
1988
Last inspected
2 December 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8603353 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
408357
Flag
ESTONIA
—
Maury page id
psix-408357

Inspections, by type

…with no type recorded12
Years with a record 7 calendar years (1997–2004)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6395 - Convention (Subpart B), Gross Ton
2864 - Convention (Subpart B), Net Ton
11249 - Displacement, Ton
7050 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

2 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2252572
26 November 2004 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2247879
7 August 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1662270
27 July 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1652843
29 January 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1486258
26 July 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 292290
1 March 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 135757
13 January 2001 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 286037
19 September 2000 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 282030
25 May 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 89405
28 March 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 276299
18 February 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 425749
25 February 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 413032
20 July 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 405797
7 July 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 405432

Deficiency record · 7

Lifesaving › Launching Appliances
Issued 27 July 2002 Resolved
Lifeboat davit brake will not stop decent of lifeboat without external pressure supplied by crewmember. LEGACY COMPONENT DESC: Winch Brake
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2002
Resolved 7 August 2002
Resolution: MSO accepted letter attesting to completion of this outstanding requirement. See narrative for details.
Lifesaving
Issued 25 February 1998 Resolved
4 smoke and 12 hand flare on the bridge are expired.
Condition: Unknown
Due 26 February 1998
Resolved 28 February 1998
Lifesaving
Issued 25 February 1998 Resolved
Liferafts have no documentation indicating the last service date.
Condition: Unknown
Due 26 February 1998
Resolved 28 February 1998
Fire Fighting
Issued 25 February 1998 Resolved
Fire Control Plans missing on the starboard side.
Condition: Unknown
Due 26 February 1998
Resolved 28 February 1998
Fire Fighting
Issued 25 February 1998 Resolved
Fire stations missing equipment and siezed throughout the ship.
Condition: Unknown
Due 26 February 1998
Resolved 28 February 1998
Navigation
Issued 7 July 1997 Resolved
RUDDER WILL ONLY TRAVEL 33 DEGREES IN EITHER DIRECTION. CLASS TO ADDRESS AND RECOMMEND REPAIRS.
Condition: Unknown
Due 11 July 1997
Resolved 16 July 1997
Deck/Cargo
Issued 7 July 1997 Resolved
PORT LIFEBOAT FWD UPPER SHEEVE FROZEN.
Condition: Unknown
Due 11 July 1997
Resolved 16 July 1997