MAURY USCG vessel records Sign in
← All vessels

GREEN ITALIA

GREEN ITALIA is a 1994 freight ship. The Coast Guard has recorded 39 inspections since 1994, most recently in October 2021, along with 8 deficiencies and 5 operational controls.

Records from 1994 to 2021. Most recent: inspection, 23 October 2021.

Built
1994
Last inspected
23 October 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9045780 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
408363
Flag
BAHAMAS, THE
—
Maury page id
psix-408363

Inspections, by type

…with no type recorded19
Years with a record 15 calendar years (1994–2021)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it7743 - Convention (Subpart B), Gross Ton
3726 - Convention (Subpart B), Net Ton
12885 - Displacement, Metric Ton
7721 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 39

23 October 2021 Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7338113
26 July 2021 PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7263877
26 February 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7142376
20 February 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7143364
25 February 2019 In-Service Inspection · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6626921
3 February 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6619275
1 February 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6618593
1 February 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6628012
22 January 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6604815
12 December 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6323358
7 November 2017 PII Safety Exam · COE-Offshore · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6299041
1 November 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6298948
7 May 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6140515
3 February 2017 COE-Dockside · Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6079345
2 February 2017 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6082344
5 July 2016 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5929804
16 December 2015 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5783153
14 December 2015 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5781395
8 December 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5777534
7 December 2015 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5776966
4 December 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5775767
4 December 2015 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5775776
23 June 2014 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4896814
18 December 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3382077
10 July 2007 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2990285
8 July 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2988326
23 April 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2913432
24 January 2006 ISPS I Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2569993
12 April 2000 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 276811
6 April 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 276487
25 March 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 426789
15 November 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 410022
5 November 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 397352
24 October 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 396741
18 December 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 385938
11 July 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 702816
8 June 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 379320
31 January 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 460461
21 June 1994 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 367839

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 26 July 2021 Resolved
07103 - Division - decks, bulkheads and penetrations. In addition to complying with the specific provisions for fire integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 44.1 and 44.2. "A" class divisions are these divisions formed by bulkheads and decks which comply with the following: they shall be so constructed as to be capable of preventing the passage of smoke and flame to the end of the one hour standard fire test. PSCO observed several cable penetrations with no fire retardant insulation, in battery room outside of bridge. SOLAS 74/78 97 Cons. Ch.II-2 Reg.44
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 July 2021
Resolved 22 October 2021
Resolution: Vessel submitted class report satisfying requirements for repair.
Engineering › Electric Propulsion System › Remote Control Circutry
Issued 16 December 2015 Resolved
Where remote control of propulsion machinery from the navigation bridge is provided and the machinery spaces are intended to be manned, the following shall apply: the speed, direction of thrust, and if applicable, the pitch of the propeller shall be fully controllable from the navigation bridge The ship reported malfunction of the remote control of the main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2016
Resolved 28 December 2015
Resolution: Received, reviewed, and acknowledged class survey report attesting to the satisfactory condition of the remote control for the main engine.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 December 2015 Resolved
1740- Oil filtering equipment shall ensure that any oil mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. Oil content meter is not being calibrated per maintenance manual. MARPOL Annex I Reg 14.6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2015
Resolution: Received class report from DNV-GL. New oil content meter installed and tested to satisfaction of class.
Communications › Alarms/Indicators › General Alarm
Issued 11 December 2015 Resolved
1010- General emergency alarm system shall be used for notifying crew and passengers of fire. PSCO observed the general emergency alarm indicator panel in the engine room on -03 deck is non-operational. 74SOLAS(04 CONS) II-2/12.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 December 2015
Resolved 11 December 2015
Resolution: Engineering crew on vessel rectified deficiency while PSCO was still on board. System was tested and is working as intended.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 18 December 2008 Resolved
A second source of energy shall be provided for an additional three starts within 30 min. unless manual starting can be demonstrated to be effective. Vessel could not start emergency generator trough secondary means of hydraulic hand pump
Action required: 705 - Other - as specified
Due 19 December 2008
Resolved 20 December 2008
Resolution: Received report from DNV regarding the permanent repairs and proper operation of primary and secondary means of starting the emergency generator.
Navigation › Collision/Grounding Avoidance › Radar
Issued 8 July 2007 Resolved
Vessels S-Band and X-Band radar is inopperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2008
Resolution: repaired, visually inspected.
Fire Fighting
Issued 6 April 2000 Resolved
IAW SOLAS 74/78 CHAP III REG. 18.3.3.1 Fire Drill not conducted due to bunker and cargo operations
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Navigation
Issued 8 June 1995 Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ONBOARD.
Condition: Unknown
Due 8 June 1995
Resolved 9 June 1995

Ownership record