Records from 1994 to 2025. Most recent: inspection, 16 January 2025.
Inspection history · 154
16 January 2025
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8077848
8 January 2025
Administrative Inspection · Load Line/Change of Employment
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8060175
14 February 2012
Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4245833
2 August 2011
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4157100
20 January 2011
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3929925
20 December 2010
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3913744
13 September 2010
MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3849864
1 September 2010
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3839899
16 March 2010
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3697476
16 December 2009
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3653420
30 March 2009
Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3442882
30 December 2008
MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3442909
29 September 2008
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3334609
5 September 2008
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3321066
26 June 2008
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3340808
10 April 2008
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3189176
17 January 2008
MTSA Verification · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3189164
10 September 2007
Hull Examination · COI Inspection · Administrative Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3055934
19 June 2007
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2980926
15 March 2007
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2888492
13 February 2007
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2872454
7 February 2007
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2869165
1 February 2007
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2866503
30 January 2007
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2868892
8 September 2006
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2824049
19 July 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2718188
21 June 2006
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2719352
23 March 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2608045
15 March 2006
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2840484
19 September 2005
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2496369
22 August 2005
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2470774
14 June 2005
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2390514
25 March 2005
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2319378
8 December 2004
Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2258846
7 September 2004
Internal Structural Exam · Underwater Inspection in lieu of Drydock · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2189628
16 June 2004
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2100292
16 March 2004
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2101334
16 December 2003
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1965901
19 November 2003
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1951045
9 September 2003
COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1894866
17 June 2003
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1819599
11 March 2003
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1784540
17 December 2002
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1719907
6 November 2002
Deadweight Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1710139
10 September 2002
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1673499
10 September 2002
COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1673530
11 June 2002
Quarterly Examination · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1628882
22 May 2002
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1619625
12 April 2002
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1604229
13 March 2002
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1493321
18 December 2001
Quarterly Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1601067
3 October 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1074861
3 October 2001
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1077146
13 September 2001
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1443250
19 June 2001
Deadweight Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1068191
11 June 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1379496
21 March 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1060707
20 February 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1057961
17 January 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1056924
4 October 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 822635
14 September 2000
Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1405073
12 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 822087
25 July 2000
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1051838
19 June 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 818800
15 June 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 819004
12 June 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1466697
22 May 2000
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1050210
16 May 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1052116
14 March 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1433627
20 January 2000
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442950
12 January 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 817394
14 December 1999
Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470543
12 November 1999
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 805666
8 November 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 11189
25 October 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 57620
25 October 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 132825
25 October 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1130857
22 October 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1361199
18 October 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399212
13 September 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399177
1 September 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 782219
7 July 1999
Deficiency Check · Deadweight Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413569
16 June 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459513
8 March 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1375673
11 January 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 811225
14 December 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1467578
15 September 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1461084
25 August 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 702550
25 July 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 13081
15 June 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400800
9 June 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 150167
14 April 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411657
16 March 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428911
8 December 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 222764
8 December 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448981
4 November 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 118897
17 October 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1111894
29 September 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 169139
29 September 1997
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1406196
15 September 1997
Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1364355
23 June 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1112196
16 June 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400589
25 April 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1100993
25 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1107440
17 March 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1100117
11 March 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446456
16 January 1997
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1383425
15 January 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 928
15 January 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 132440
15 January 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 232095
27 December 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1094497
18 December 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359321
26 September 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 102875
16 September 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413051
28 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 127084
17 July 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1360568
17 June 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1443713
11 April 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 21086
25 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 68842
21 March 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404109
20 March 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1078535
18 March 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407629
16 January 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359024
18 December 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458259
13 October 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398359
19 September 1995
COI Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442297
17 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 180450
17 August 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385522
25 July 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 227019
7 July 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1192008
29 June 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1452042
20 June 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1189058
20 May 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 930172
20 April 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1357123
20 March 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1355147
16 March 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 162138
16 March 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1357059
6 March 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 10787
7 February 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1146801
31 January 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442210
9 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 858421
7 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 154757
3 January 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1429982
31 December 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 101507
31 December 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 127622
2 December 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 180516
24 November 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 169405
18 November 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 101284
20 October 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 171335
19 October 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 35911
18 October 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 164572
14 October 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 867556
1 October 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 164621
19 September 1994
Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1177782
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 14 February 2012
No resolution recorded
Test to the satisfaction of the USCG, all high J/W temperature gauges and sensing bulbs for all MDE's, SSDG's and emergency generator.
Action required: 705 - Other - as specified
Resolution: Eagle control systems, Inc. was hired by ship to test all required instruments. Service report was provided.
Electrical › Electric Supply System (service) › Cable
Issued 14 February 2012
Resolved
In all compartments check that all wiring is held by metal bands and not plastic wire ties. Replace any that are necessary.
Action required: 705 - Other - as specified
Resolved 9 April 2012
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 14 February 2012
Resolved
Make cable way in Food prep room to Liquor locker room, fire and fume tight.
Action required: 705 - Other - as specified
Resolved 9 April 2012
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 14 February 2012
Resolved
Repair or renew tachometer for #2 SSDG and test overspeed shutdown device in the presence of a marine inspector or ABS Surveyor.
Action required: 705 - Other - as specified
Resolved 9 April 2012
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 14 February 2012
Resolved
Renew Di-electric matting in front of main switchboard in accordance with 46 CFR 111.30-11
Action required: 705 - Other - as specified
Resolved 9 April 2012
Stability › Watertight Integrity › General
Issued 14 February 2012
Resolved
Replace gasket in Emergency escape scuttle in the workshop.
Action required: 705 - Other - as specified
Resolved 9 April 2012
Stability › Watertight Integrity › General
Issued 14 February 2012
Resolved
Adjust #2 watertight door, and prove proper operation to the attending Inspector or Surveyor.
Action required: 705 - Other - as specified
Resolved 9 April 2012
Fire Fighting › Combustible Materials › Ceilings
Issued 14 February 2012
Resolved
Install missing false ceiling tiles in all compartments missing ones.
Action required: 705 - Other - as specified
Resolved 9 April 2012
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 14 February 2012
Resolved
Prove to the attending Inspector, low lube oil shutdown, overspeed trip and High water temp for the emergency generator.
Action required: 705 - Other - as specified
Resolved 9 April 2012
Lifesaving › Launching Appliances › Falls
Issued 14 February 2012
Resolved
Replace Rescue boat davit lifting cables for both forward and aft davits, and perform weight test in the presence of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 9 April 2012
Resolution: Both fwd and aft cables were replaced and tested for 110% overload test. All were sat.
Lifesaving › Rescue Boat › Markings
Issued 14 February 2012
Resolved
Replace aft rescue boat fwd running light lens with a new one.
Action required: 705 - Other - as specified
Resolved 9 April 2012
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 14 February 2012
Resolved
Renew all removed structural fire protection throughout all engineering spaces.
Action required: 705 - Other - as specified
Resolved 9 April 2012
Engineering › Generator (propulsion/auxiliary-electric) › Reverse Power Protection Relay Circuitry
Issued 2 August 2011
Resolved
Prove proper operation of the #2 SSDG Reverse Power Relay.
Action required: 705 - Other - as specified
Resolved 9 April 2012
Resolution: Reverse power relays work consistently when all three generators are online and paralleled. When doubled up and in any configuration the relays do not operate consistently. If the vessel has to go on ships power it must put all three generators online.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 2 August 2011
No resolution recorded
Prove proper operation of the Main chiller unit isolation valves.
Action required: 705 - Other - as specified
Resolution: Waiver request for the operation of the Main Chiller Unit isolation valves. Once vessel enters the state inspection program, ABSC will require the demonstration of all the valves to work properly.
Stability › Watertight Integrity › General
Issued 2 August 2011
Resolved
Perform maintenance on work shop emergency escape scuttle.
Action required: 705 - Other - as specified
Resolved 22 November 2011
Stability › Watertight Integrity › General
Issued 2 August 2011
Resolved
Renew Water Tight Door gasket on the #6 door.
Action required: 705 - Other - as specified
Resolved 22 November 2011
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 2 August 2011
Resolved
Prove proper operation of all rudder angle indicators.
Action required: 705 - Other - as specified
Resolved 22 November 2011
Stability › Watertight Integrity › General
Issued 2 August 2011
Resolved
Perform maintenance on escape scuttle for women's bathroom to the rudder room.
Action required: 705 - Other - as specified
Resolved 22 November 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 August 2011
Resolved
Permanently mount forward running light on starboard aft rescue boat.
Action required: 705 - Other - as specified
Resolved 22 November 2011
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 2 August 2011
Resolved
Re-mount blank in breaker panel P-408, 3rd deck storage closet.
Action required: 705 - Other - as specified
Resolved 22 November 2011
Electrical › Electric Supply System (service) › Cable
Issued 2 August 2011
Resolved
Remove all unused com wires in the engine room and chiller room.
Action required: 705 - Other - as specified
Resolved 22 November 2011
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 20 December 2010
Resolved
Remove and store all loose electronic gear, boxes and misc gear from slot tech and supervisor repair shops.
Due 20 January 2011
Resolved 20 January 2011
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 20 December 2010
Resolved
Prove proper operation of both #1 & 2 ship service generator tachometers.
Due 20 January 2011
Resolved 20 January 2011
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 20 December 2010
Resolved
Make permanent repairs to portside second deck lifejacket stowage box.
Due 20 January 2011
Resolved 20 January 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (air start)
Issued 20 December 2010
Resolved
Prove proper operation of the Port MDE start valve
Due 20 January 2011
Resolved 20 January 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 September 2010
Resolved
The CO2 manifold hoses are overdue (5) five year hydro test.
Action required: 705 - Other - as specified
Due 17 September 2010
Resolved 17 September 2010
Resolution: The CO2 manifold hoses where replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 13 September 2010
Resolved
The dampers in the emergency generator room do not close when CO2 system is activated.
Action required: 705 - Other - as specified
Due 17 September 2010
Resolved 15 September 2010
Resolution: The dampers in the emergency generator room do close when CO2 system is activated.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 September 2010
Resolved
Repair piping that is leaking gray water in aft stbd void.
Action required: 705 - Other - as specified
Due 15 October 2010
Resolved 15 October 2010
Resolution: Leaking pipe in aft stbd void has been repaired.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 September 2010
Resolved
Document sewage system in rudder room. Extended requirement to 17DEC10 due to availability of naval engineer.
Action required: 705 - Other - as specified
Due 20 March 2011
Resolved 27 May 2011
Construction/Loadline › Structures › Door
Issued 13 September 2010
Resolved
Repair #1 hydraulically operated door mechanical indicator.
Action required: 705 - Other - as specified
Due 15 October 2010
Resolved 15 October 2010
Resolution: The indicator on the #1 hydraulic door has been replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 September 2010
Resolved
Change out running lights due to warning alarms on bridge.
Action required: 705 - Other - as specified
Due 15 October 2010
Resolved 15 October 2010
Resolution: Running lights have been replaced.
Fire Fighting › Automatic Sprinkler System › Stop Valves
Issued 13 September 2010
Resolved
Repair the crossover valve on the sprinkler system
Action required: 705 - Other - as specified
Due 15 October 2010
Resolved 15 October 2010
Resolution: Sprinkler crossover valve has been permanently repaired.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Blower, Centrifugal
Issued 30 March 2009
Resolved
The #2 generator would not start due to condensation in the air line.
Due 8 April 2009
Resolved 6 April 2009
Resolution: Measure made to reduce the condensation in the air lines to the #2 generator.
Engineering › Diesel Engine (propulsion-direct drive) › Blower, Centrifugal
Issued 30 March 2009
Resolved
Stbd main would not start due to condensation in air line
Due 8 April 2009
Resolved 6 April 2009
Resolution: Condensation problem resolved.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 March 2009
Resolved
Outside deck lighting out in many areas. These lights are required not only for safety but for MTSA.
Due 8 April 2009
Resolved 6 April 2009
Resolution: Outside deck lighting replaced.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 5 September 2008
Resolved
Provide local USCG OCMI with proposal for a mooring configuration that will withstand 150 MPH winds in hurricane conditions. A professional engineering assessment will be requried.
Action required: 705 - Other - as specified
Due 6 October 2008
Resolved 5 September 2008
Engineering › Diesel Engine (propulsion-electric) › Crankcase
Issued 19 June 2007
Resolved
Place gaskets on main, first and secondary oil plans on #1, #2, and #2 generators.
Action required: 705 - Other - as specified
Due 19 July 2007
Resolved 3 August 2007
Resolution: Gaskets replaced on the #1, #2 and #3 generators.
Engineering › Diesel Engine (propulsion-electric) › Distributor (air start)
Issued 19 June 2007
Resolved
Replace starter on the #2 generator.
Action required: 705 - Other - as specified
Due 3 July 2007
Resolved 3 August 2007
Resolution: Starter on the #2 generator replaced.
Engineering › Generator (propulsion-electric) › Junction Box
Issued 19 June 2007
Resolved
Bundle wires on all generators.
Action required: 705 - Other - as specified
Due 3 July 2007
Resolved 3 August 2007
Resolution: Wires bundled on generators.
Engineering › Bilge Water Management System › Eductor
Issued 19 June 2007
Resolved
Clean bilge in engine rooms.
Action required: 705 - Other - as specified
Due 3 July 2007
Resolved 3 August 2007
Resolution: Engine room bilges cleaned.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 13 February 2007
Resolved
Capt. was not on board vsl for almost 2 hours. He was attending a meeting w/ GM over a mile away.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 February 2007
Resolved 13 February 2007
Resolution: Evacuation drill was conducted and Capt returned to the vsl.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 7 February 2007
Resolved
Employee ramp was closed, chained and locked. The ramp is part of the approved evacuation plan.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 February 2007
Resolved 7 February 2007
Resolution: Security personnel were moved and the ramp was open.
Operations/Management › Navigation Safety › Proper Lookout
Issued 30 January 2007
Resolved
Capt was not onboard vessel as required by the COI. Capt was on land at a meeting with General Manager for over 3 hours. Inspector conducted a fire drill to determine if Capt could make it back in time to the vessel. Should have conducted an evactuation drill, but started with a fire drill.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2007
Resolved 30 January 2007
Resolution: Capt was instructed that they are required to be on board the vessel at all times. [name withheld] stated that they go to a meeting with GM every week.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 14 December 2006
Resolved
Current COFR expired on 22 OCT 06. A call to the COFR deck revealed that owners did not apply for renewal until 12 DEC 06. CFOR is being sent in overnite mail. Case has been given to local USCG investigators for action.
Action required: 705 - Other - as specified
Resolved 15 December 2006
Resolution: A call to the COFR deck revealed that the vessel had applied for a COFR recently and was being processed. However the vessel was without a current COFR from 22OCT06 to 12DEC06. The case was given to the investigations dept for further action.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 14 December 2006
Resolved
MSC approval letter for reconfiguration of first deck and new fire evacuation plan must also bevised to reflect changes
Action required: 705 - Other - as specified
Resolved 15 January 2007
Engineering › Freshwater System (air cooling) › Hose
Issued 14 December 2006
Resolved
Replace painted and worn hoses on #1, #2, and #3 generators.
Condition: Placed in Improper Service
Due 15 February 2007
Resolved 14 December 2006
Engineering › Diesel Engine (propulsion-electric) › Cylinder Head
Issued 14 December 2006
Resolved
Replace rear seals on both #2 and #3 engines.
Due 15 February 2007
Resolved 15 May 2007
Resolution: Rear seals on both #2 and #3 engines.
Construction/Loadline › Hull › Bottom Plating
Issued 8 September 2006
No resolution recorded
Vessel was not going to conduct their annual ISE. They were unable to locate theri maintenance plan for their AHE.
Action required: 705 - Other - as specified
Due 9 September 2006 — due date passed with no resolution recorded
Resolution: Casino hired third party examiner to conduct ISE. All sat.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 September 2006
Resolved
Confined Space entry procedures needed to be updated to show all designated spaces.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 11 September 2006
Resolution: Updated plan.
Fire Fighting › Means of Escape › Doorways
Issued 8 September 2006
Resolved
FSD #9 was not operating correctly.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 8 September 2006
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 September 2006
Resolved
Replace all covers on all electrical junction boxes.
Action required: 705 - Other - as specified
Due 11 September 2006
Resolved 11 September 2006
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 September 2006
Resolved
Vessel was unable to locate their emergency evacuation plan. Required to locate and follow plan.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 8 October 2006
Resolution: Vessels emergency evacuation plan located and in use.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 September 2006
Resolved
Need to place non-skid around rescue boats. Area is extremely slippery.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 11 September 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 8 September 2006
Resolved
New doors need to be installed on 1st deck portside w/ fire rating plaque. Door is punctured.
Three other outside doors on all decks need to be replaced IAW fire plan. They are wasted and worn.
Doors are to be ordered.
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 14 December 2006
Resolution: New doors installed as required.
Lifesaving › Rescue Boat › Hull (inflated)
Issued 8 September 2006
Resolved
Both rescue boats have leaks in hull. Must repair IAW manufactor specifications.
Action required: 705 - Other - as specified
Due 18 September 2006
Resolved 14 December 2006
Resolution: The leaks in both rescue boats have been repaired.
Construction/Loadline › Structures › Deck Plating
Issued 21 June 2006
Resolved
All outside weather decks need to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2006
Resolved 13 February 2008
Resolution: Weather decks have been repaired.
Engineering › Non-conventional Propulsion/Steering › Well-flange (z-drive)
Issued 21 June 2006
Resolved
Paddle wheel needs to be repaired. 90% of boards are missing or rotting away. Paddle wheel makes up approx. 25% of propulsion on vsl.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2006
Resolved 21 September 2006
Resolution: Paddle wheel boards have been replaced.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 21 June 2006
Resolved
Wiring in cages into the fuse boxes. The wires need to be installed correctly. Additionally, all wires dead wires need to be corrected/removed throughout ship.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2006
Resolved 28 June 2006
Accommodation/Occupational Safety › Potable Water System › General
Issued 21 June 2006
Resolved
Repair water leak in pipe located in liquar room. Additionally, repair floor
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2006
Resolved 28 June 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 June 2006
Resolved
Repair life jacket box fwd port side.
Action required: 705 - Other - as specified
Due 28 June 2006
Resolved 28 June 2006
Resolution: Replaced hook on box.
Accommodation/Occupational Safety › Other Accommodation Spaces › Insect Screen
Issued 21 June 2006
Resolved
Liquar room and food prep area need to be fumigated for bugs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2006
Resolved 22 June 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 September 2005
Resolved
Replace line to emergency light on stbd lifebuoy and replace line on lifering on port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 September 2005
Resolved 20 September 2005
Resolution: Line replaced on emergency light on stbd lifebuoy and line replaced on port side bouy.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 19 September 2005
Resolved
Repair port side outside decking (stairway to stariway) on fwd port side 3rd deck.
Condition: Damaged By Earlier Event
Due 13 October 2005
Resolved 13 October 2005
Resolution: Outside decking on fwd port side 3rd deck repaired.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 19 September 2005
Resolved
Prime/paint around bottom edge of bulkhead on 2nd and 3rd deck.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 October 2005
Resolved 13 October 2005
Resolution: Primed/painted around bottom edge of bulkhead on 2nd and 3rd deck.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 September 2005
Resolved
Insure that fire doors are operating properly (1st deck/AFT).
Condition: Unknown
Due 13 October 2005
Resolved 13 October 2005
Resolution: Fire doors on 1st deck aft operating properly.
Navigation › Collision/Grounding Avoidance › Radar
Issued 19 September 2005
Resolved
Replace/repair 3" radar on bridge
Condition: Unknown
Due 20 September 2005
Resolved 20 September 2005
Resolution: Replaced 3" radar on bridge.
Engineering › Feedwater/Condensate Water System › Piping
Issued 19 September 2005
Resolved
Find plans authorizing copper piping in the lower decks. If there is no proof of authorizing copper remove immediately.
Condition: Improper Installation
Due 27 September 2005
Resolved 18 October 2006
Resolution: Copper piping authorized on vessel.
Engineering › Fuel Oil Service System › Filter
Issued 19 September 2005
Resolved
Place "Pet Cock" on fuel filter reservoir.
Condition: Unknown
Due 27 September 2005
Resolved 27 September 2005
Resolution: Placed "Pet Cock" on fuel filter reservoir.
Construction/Loadline › Structures › Door
Issued 19 September 2005
Resolved
Remove fwd work area in lower hold or submit plans for approval of emergency escape hatch to MSC.
Condition: Design Flaw
Due 11 November 2005
Resolved 11 November 2005
Resolution: Plans submitted for approval for emergency excape hatch to MSC.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 22 August 2005
Resolved
A malfunction in the CO2 fixed fire system malfunctioned causing a discharge of the C02 system in the engine/generator spaces.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 August 2005
Resolved 30 August 2005
Resolution: New CO2 bottles/activation heads installed. Proper testing of fixed fire system tested, all sat. Fixed fire system properly armed and placed on line.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 14 June 2005
Resolved
Replace/repair broken re-enforced glass on fire station on top deck, port side on aft entrance.
Condition: Unknown
Due 28 June 2005
Resolved 28 June 2005
Resolution: Broken re-enforced glass on fire station on top deck, port side/aft entrance repaired.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 14 June 2005
Resolved
Replace/repair broken re-enforced glass on double doors on third deck port bow.
Condition: Unknown
Due 28 June 2005
Resolved 28 June 2005
Resolution: Broken re-enforced glass on double doors on third deck replaced.
Construction/Loadline › Structures › Air Pipe
Issued 14 June 2005
Resolved
Replace molded covers on wine and CO2 lines in beer cooler.
Condition: Unknown
Due 28 June 2005
Resolved 28 June 2005
Resolution: Molded covers on wine and CO2 lines in beer cooler replaced.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 14 June 2005
Resolved
Prepare a repair proposal for repair of wasted area behind stbd fire door on first deck aft bar area.
Condition: Unknown
Due 28 June 2005
Resolved 28 June 2005
Resolution: Wasted area behind fire door stbd first deck fire door fixed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 14 June 2005
Resolved
Insure that fire door on stbd side, first deck AFT, closes properly when fire door button is pushed.
Condition: Unknown
Due 28 June 2005
Resolved 28 June 2005
Resolution: Fire door operating properly.
Fire Fighting › Fire Hoses › Connections
Issued 25 March 2005
Resolved
Replace spanner wrenchs at fire stations that are unable to tighten fire hoses.
Condition: Unknown
Due 22 April 2005
Resolved 1 October 2005
Resolution: Submitted plan to correct.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 March 2005
Resolved
Place cover on wiring on liquor distribution system.
Condition: Design Flaw
Due 22 April 2005
Resolved 10 August 2005
Resolution: Replaced covers.
Deck/Cargo › Cargo Stowage › General
Issued 25 March 2005
Resolved
Place rubber mats under CO2 bottles in liquor room and crew break room.
Condition: Unknown
Due 22 April 2005
Resolved 10 August 2005
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 25 March 2005
Resolved
Remove molded laging in engine and chiller room.
Condition: Unknown
Due 22 April 2005
Resolved 10 August 2005
Resolution: Contracted out to have company come in and replaced all insulation in Eng Rm and Chiller RM.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 25 March 2005
Resolved
Remove condensation on long frames on port and stbd sides of engine room.
Condition: Unknown
Due 22 April 2005
Resolved 10 August 2005
Resolution: Cleaned bilge.
Accommodation/Occupational Safety › Ventilation › General
Issued 25 March 2005
Resolved
Remove/replace damaged ceiling tiles on lower deck.
Condition: Unknown
Due 22 April 2005
Resolved 10 August 2005
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 25 March 2005
Resolved
Replace missing butterfly valve handle until Winter when entire valve will be replaced.
Condition: Unknown
Due 22 April 2005
Resolved 10 August 2005
Resolution: Valve handles replaced.
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 25 March 2005
Resolved
Update marine inspectors of status on new fire protection plans.
Condition: Unknown
Due 22 April 2005
Resolved 10 August 2005
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 25 March 2005
Resolved
Dtermine status of emergency red light in surveillance room and replace or remove.
Condition: Unknown
Due 22 April 2005
Resolved 10 August 2005
Resolution: Light removed.
Accommodation/Occupational Safety › Ventilation › General
Issued 25 March 2005
Resolved
Submit a confined spaces are properly stenciled throughout ship.
Condition: Unknown
Due 22 April 2005
Resolved 10 August 2005
Resolution: All placed have been marked appropriately.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 December 2004
Resolved
Fire Control Plan needs to be updated. Old FCP does not have new approved IMO symbols and quantity numbers.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 January 2005
Resolved 10 January 2005
Resolution: Fire control plan is being drafted and posted.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 7 September 2004
Resolved
Correct drywall outside of beverage bar located on 2nd deck. Drywall was damaged by cart being smashed into the wall. Crew is not be careful.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2004
Resolved 16 November 2004
Resolution: Drywall has been replaced.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 16 June 2004
Resolved
Glass in fire door located on 2nd deck fwd port side broken.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 30 June 2004
Resolution: Glass replaced in door.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 16 June 2004
Resolved
Bulkhead in lower hold across from galley has been punctured by cart traffic in passageway. Vsl to determine best way to repair and prevent from reoccurance, and submit to office.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 30 June 2004
Resolution: Corrected bulkhead.
Engineering › Lubricating Oil Service System › Tank
Issued 16 June 2004
Resolved
Cover for hydraulic pump for passenger elevator was cut. Cover needs to be replaced.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 16 June 2004
Resolution: Cover was replaced.
Lifesaving › Launching Appliances › Falls
Issued 15 June 2004
Resolved
Date of installation of falls on both rescue boats is unknow. Believed to be original. Cable is worn and beginning to split. Replace cable IAW chapter W.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 30 June 2004
Resolution: Replaced falls on rescue boats.
Documentation › Safety/Response Plans/Programs
Issued 16 December 2003
Resolved
Vessel had new fire safety plan drawen up, but did not place through out the vessel. Only placed new/updated copy on bridge. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 December 2003
Resolved 16 December 2003
Resolution: New fire control plan.
Lifesaving › Inflatable Liferafts
Issued 16 December 2003
Resolved
All IBA's on board vessel need to be properly installed with hydrostatic release units. Painters are just woven through can bindings. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 December 2003
Resolved 22 December 2003
Fire Fighting › Structural - B Class Divisions › Doors
Issued 16 December 2003
Resolved
Conduct maintenance on FSD #8 on 1st deck.
Condition: Improper/Lack of Maintenance
Due 16 December 2003
Resolved 16 December 2003
Resolution: Conducted maintenance for proper operation of fire door.
Lifesaving › Lifejacket/PFD (General)
Issued 16 December 2003
Resolved
Lifejacket box at stern is marked for 80 PFD's. Vessel needs to remove or restensile box to proper number.
LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 December 2003
Resolved 16 December 2003
Resolution: Restinciled box.
Construction/Loadline › Structures
Issued 16 December 2003
Resolved
Vessel replaced floor in lower hold with a CG approved epoxy compound. Due to improper installation, the door in the lower hold will not shut. Vessel is contacting company to come out and correct the problem. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 January 2004
Resolved 24 December 2003
Resolution: Floor replaced with epoxy compound.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 December 2003
Resolved
Remove extension cords and power stripes for various office spaces throughout the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2003
Resolved 16 December 2003
Resolution: Removed all extension cords and power stripes.
Engineering › Generator (propulsion-electric)
Issued 16 December 2003
Resolved
Small boat batteries needs to be moved to an approved storage area. Currently on a lower shelf in a cabinet. LEGACY COMPONENT DESC: Battery
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 December 2003
Resolved 24 December 2003
Engineering › Lubricating Oil Service System
Issued 16 December 2003
Resolved
Fix F/O leak on #2 Gen suply valve; #3 gen racor; and F/O leak emerg. gen room racor. LEGACY COMPONENT DESC: Filter
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2003
Resolved 16 December 2003
Construction/Loadline › Structures
Issued 16 December 2003
Resolved
Readjust WTD's in lower hold to close properly.
LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 January 2004
Resolved 15 January 2004
Pollution Prevention/Response › Prevention Equipment
Issued 16 December 2003
Resolved
Remove all trash and oil residue in bilges. LEGACY COMPONENT DESC: Oily Residue (sludge/slop) Tank
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2003
Resolved 16 December 2003
Lifesaving › Inflatable Liferafts
Issued 9 September 2003
Resolved
Inflatable liferafts were expired. Vsl needs to have them serviced and restored on vsl. IBA's expired on July 2003. Vsl did not comply for hopes that they would recieve exemption for inflatable liferafts on Oct 1, 2003 deadline.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2003
Resolved 7 November 2003
Resolution: Vessel has had all IBA''s serviced and installed. Vsl now meets new Subchapter W requirements, MSO NOLA has issued policy letter requiring vessel to meet 10% IBA for Subchapter W.
Documentation › Manuals/Policy Documentation
Issued 9 September 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 26 October 2003
Resolution: Station Bill was posted.
Electrical › Electrical Distribution System (service)
Issued 9 September 2003
Resolved
Install blanks in all fuse boxes throughout the vessel. Repair fuse box door located in Guest Services 2nd deck. LEGACY COMPONENT DESC: Fuse
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 1 October 2003
Resolution: Installed blanks in all fuse boxes.
Electrical › Electrical Distribution System (service)
Issued 9 September 2003
Resolved
Remove all power stripes and extension cords in all spaces. Vessel has placed power stripes in spaces instead of using good judgment and hard wiring all electronic equipment. Rooms include: Bell 5, Surveillance Room, Slot Office, Phone rm, tec rom, slot tec room, repair parts slot rm, state polic LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 1 October 2003
Resolution: Removed power stripes and extension cords.
Construction/Loadline › Structures
Issued 9 September 2003
Resolved
Vessel placed aluminum plating down on deck to protect already broken deck from cart traffic. Now plating has wasted. Vessel is to submit repair proposal for deck in area of cart storage though galley area. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 1 October 2003
Resolution: Aluminum plating has been replaced and repair proposal has been submitted and reviewed for epoxy covering on deck.
Construction/Loadline › Structures
Issued 9 September 2003
Resolved
Adjust all manual WTD. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 1 October 2003
Resolution: Adjusted WTD''s.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 9 September 2003
Resolved
Make repairs to f/o and j/w leaks on emergency generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 1 October 2003
Resolution: All leaks have been corrected.
Construction/Loadline › Structures
Issued 9 September 2003
Resolved
Provide hatch securing assembly on hatch leading to sprinkler room.
LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 1 October 2003
Resolution: hatch securing assembly has been installed.
Electrical › Electrical Distribution System (service)
Issued 9 September 2003
Resolved
Remove all plastic tie wraps and replace with metalic ties in emergency generator room. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 1 October 2003
Resolution: Metalic wire ties have been installed.
Fire Fighting › Miscellaneous Items
Issued 9 September 2003
Resolved
Vessel to conduct a fire drill on board with local fire department. Vessel has no knowledge of conducting fire drill with local frie dept. Fire dept will be main responder, must ensure familiarity with vessel.
Action required: 705 - Other - as specified
Due 1 October 2003
Resolved 16 September 2003
Resolution: Conducted sat fire drill.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 11 March 2003
Resolved
Repair starboard main engine control air valve. LEGACY COMPONENT DESC: Valve Actuating Gear
Due 14 March 2003
Resolved 13 March 2003
Fire Fighting › Fire Pumps
Issued 11 March 2003
Resolved
Repair pump seal on aux. fire pump. LEGACY COMPONENT DESC: Gland Sealing
Due 1 April 2003
Resolved 13 March 2003
Accommodation/Occupational Safety › Messroom
Issued 17 December 2002
Resolved
Clean-up main deck galley, remove all food particles. LEGACY COMPONENT DESC: cleaniness
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 11 March 2003
Lifesaving › Rescue Boat Equipment
Issued 17 December 2002
Resolved
Re-new rescue boat repair kits. LEGACY COMPONENT DESC: Repair Kit (inflated rescue boat)
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 11 March 2003
Lifesaving › Buoyant Apparatus
Issued 17 December 2002
Resolved
Re-furbish the forward lowest lifefloat.
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 15 October 2003
Resolution: 10% IBA''s on board.
Electrical › Electric Generation Source (service)
Issued 17 December 2002
Resolved
Demostrate proper operation of #2 genset reverse power relay. LEGACY COMPONENT DESC: Overcurrent Device
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 11 March 2003
Electrical › Electric Generation Source (emergency)
Issued 17 December 2002
Resolved
Demonstrate proper operation of air damper actuator in emergency generator space.
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 11 March 2003
Electrical › Lighting (emergency)
Issued 17 December 2002
Resolved
Repair emergency light aft of #3 genset.
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 11 March 2003
Electrical › Electric Generation Source (service)
Issued 17 December 2002
Resolved
Clear ground on main switchboard. LEGACY COMPONENT DESC: Ground Indicator
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 11 March 2003
Engineering
Issued 17 December 2002
Resolved
Repair water leak in overhead above back-up fire pump in main engineroom.
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 11 March 2003
Documentation › Logs/Records
Issued 17 December 2002
Resolved
Provide a log of ground faults- note date found, how cleared and date cleared. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 11 March 2003
Accommodation/Occupational Safety › Messroom
Issued 10 September 2002
Resolved
Clean deck and stop water leaks in all bar areas.
Due 10 October 2002
Resolved 6 October 2002
Lifesaving › Buoyant Apparatus
Issued 10 September 2002
Resolved
Re-new retro tape on all life floats.
Due 10 October 2002
Resolved 6 October 2002
Engineering
Issued 10 September 2002
Resolved
Remove PVC piping in overhead at 1st deck guest services.
Due 10 October 2002
Resolved 6 October 2002
Electrical › Electrical Distribution System (service)
Issued 10 September 2002
Resolved
Properly label remote stop switches for fuel oil transfer pump at starb. main deck and emergency generator space. LEGACY COMPONENT DESC: Switch
Due 10 October 2002
Resolved 6 October 2002
Electrical › Electrical Distribution System (service)
Issued 10 September 2002
Resolved
Properly secure cable in overhead above door leading to crew lounge, and replace structural fire protection material near same. LEGACY COMPONENT DESC: Wiring
Due 10 October 2002
Resolved 6 October 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 11 June 2002
Resolved
In telephone room, remove excess outlet strips and gear. Allow access to all receptacles and remaining outlet strips. LEGACY COMPONENT DESC: Receptacle Outlet
Due 11 July 2002
Resolved 14 June 2002
Fire Fighting › Structural Fire Protection - General
Issued 11 June 2002
Resolved
Properly seal stuffing block above aft video storage rack and properly stow outlet strips at aft bulkhead (under emergency light) in surveillance room.
Due 11 July 2002
Resolved 14 June 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 11 June 2002
Resolved
Clean under ice and soda machine, and provide cover for ice machine in crew's lounge.
Due 11 July 2002
Resolved 14 June 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 11 June 2002
Resolved
Remove overhead extension cord and cable and excess equipment to allow access to power strips under work bench in slot tracking office. LEGACY COMPONENT DESC: Receptacle Outlet
Due 11 July 2002
Resolved 14 June 2002
Electrical › Electrical Distribution System (service)
Issued 11 June 2002
Resolved
Properly secure cables for elevator oil cooler assemblies and at stbd aft mooring winch motor. LEGACY COMPONENT DESC: Cable
Due 11 July 2002
Resolved 14 June 2002
Fire Fighting › Miscellaneous Items
Issued 11 June 2002
Resolved
Provide updated fire control plan.
Due 11 July 2002
Resolved 10 September 2002
Communications › Alarms/Indicators › General Alarm
Issued 11 June 2002
Resolved
Prove proper operation of general alarms at 2nd deck womens head, 3rd deck stairtower, fire stations #20, main deck men's head, main deck fwd starboard side.
Due 14 June 2002
Resolved 14 June 2002
Communications › Alarms/Indicators › Fire Alarm
Issued 11 June 2002
Resolved
Repair/replace smoke detector on 2nd deck starboard side.
Due 14 June 2002
Resolved 14 June 2002
Operations/Management › Drills/Instruction
Issued 11 June 2002
Resolved
Provide qualifications and certifications for lead deck hands. LEGACY COMPONENT DESC: Safety Orientation
Due 11 July 2002
Resolved 14 June 2002
Fire Fighting › Structural Fire Protection - General
Issued 4 April 2002
Resolved
Repair the following fire screen doors, 3 Dk aft doors, Main Dk doors, Galley door, and crew break room door.
Condition: Improper/Lack of Maintenance
Due 4 April 2002
Resolved 4 April 2002
Electrical › Electrical Distribution System (emergency) › Switch
Issued 4 April 2002
Resolved
Repair sticking relays on emergency lighting test bottoms.
Condition: Improper/Lack of Maintenance
Due 4 April 2002
Resolved 4 April 2002
Engineering › Fuel Oil Service System › Valve, Control
Issued 4 April 2002
Resolved
Show proper operation of emergency fuel shut off for engineroom.
Condition: Improper/Lack of Maintenance
Due 4 April 2002
Resolved 4 April 2002
Deck/Cargo › Mooring/Anchoring
Issued 4 April 2002
Resolved
Remove logs and trash from in front of vessel.
Due 4 April 2002
Resolved 4 April 2002
Electrical › Electrical Distribution System (service)
Issued 13 March 2002
Resolved
Re-position electrical outlet strip located under fry grill on 1st deck galley. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 13 April 2002
Resolved 11 June 2002
Accommodation/Occupational Safety › Messroom
Issued 13 March 2002
Resolved
Clean up food debris from floor of 1st deck galley.
Due 13 April 2002
Resolved 11 June 2002
Electrical › Electrical Distribution System (service)
Issued 13 March 2002
Resolved
Provide cover for control box in 1st deck cashier cage. LEGACY COMPONENT DESC: Switch
Due 13 April 2002
Resolved 11 June 2002
Electrical › Electrical Distribution System (service)
Issued 13 March 2002
Resolved
Ensure all outlet strips are plugged in all the way and clean off cust and debris from them though out the vessel. LEGACY COMPONENT DESC: Outlet Box
Due 13 April 2002
Resolved 11 June 2002
Communications › Internal Communications System
Issued 13 March 2002
Resolved
Repair/ replace telephone in 2nd deck galley. LEGACY COMPONENT DESC: Sound-powered Telephone
Due 13 April 2002
Resolved 11 June 2002
Fire Fighting › Structural - A Class Divisions
Issued 13 March 2002
Resolved
Prove proper operation of fire screen doors #27 and the aft center door on the 3rd deck. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 13 May 2002
Resolved 11 June 2002
Fire Fighting
Issued 13 September 2001
Resolved
Repair sprinkler system storage tank as per manufacture recommendations._x001C_
Condition: Unknown
Due 13 November 2001
Resolved 23 October 2001
Resolution: Received documentation indicating that the repairs were completed and cleared by [name withheld] this date.
Fire Fighting
Issued 13 September 2001
Resolved
Repair latches on all Stb side sliding doors on first and second deck._x001C_
Condition: Unknown
Due 13 November 2001
Resolved 11 June 2002
Fire Fighting
Issued 13 September 2001
Resolved
Repair all fire dampers as per repair list._x001C_
Condition: Unknown
Due 13 November 2001
Resolved 11 June 2002
Construction/Loadline
Issued 11 June 2001
Resolved
Renew seals on all(3 levels) fwd doors and repair closure on main deck Stb side fwd.
Condition: Unknown
Due 11 June 2001
Resolved 11 June 2001
Electrical
Issued 11 June 2001
Resolved
Repair emergency lighting in main engine room and main deck aft port stair tower.
Condition: Unknown
Due 11 June 2001
Resolved 11 June 2001
Fire Fighting
Issued 11 June 2001
Resolved
Repair shaft packing on sprinkler pump, leaks excessive.
Condition: Unknown
Due 11 June 2001
Resolved 11 June 2001
Engineering
Issued 14 September 2000
Resolved
Label warning light in main propulsion space.
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Construction/Loadline
Issued 14 September 2000
Resolved
Repair broken door latches/handles on 2nd deck forward port and starboard side.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Electrical
Issued 14 September 2000
Resolved
Provide proper ground detection for main power board.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Lifesaving
Issued 14 September 2000
Resolved
Provide retro-reflective tape on rescue boat top and bottom sides.
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Lifesaving
Issued 14 September 2000
Resolved
Prove compliance with requirements of Subchap W.
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Fire Fighting
Issued 14 September 2000
Resolved
Update fixed CO2 OPERATING INSTRUCTION FOR THE GENERATOR AND ENGINE ROOMS TO INLCUDE SECURING OF ALL ENGINES BEFORE OPERATING SYSTEM.
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Fire Fighting
Issued 14 September 2000
Resolved
Properly seal wire gun going through liquor store room.
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Fire Fighting
Issued 14 September 2000
Resolved
Label fire pump control swithc for sprinkler system. (Control for sprinkler operation only, will not cut out remote start from bridge)
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Lifesaving
Issued 14 September 2000
Resolved
Conduct required drills while underway in the presents of a CG marine inspector.
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Electrical
Issued 14 September 2000
Resolved
Properly install electrical wires at motor on conveyor belt in hard_x001C_ room.
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Electrical
Issued 14 September 2000
Resolved
Properly support electrical outlet strip at 3rd deck bar.
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Accommodation/Occupational Safety
Issued 14 September 2000
Resolved
Open pressure vessel storage tank for fire sprinkler system for examination.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Lifesaving
Issued 14 September 2000
Resolved
Secure cigarette machine on 3rd deck.
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Accommodation/Occupational Safety
Issued 14 September 2000
Resolved
Clean up deck in 2nd deck bar and remove power cord sitting in water.
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Electrical
Issued 14 September 2000
Resolved
Relocate 110v outlet or soda gun in 1st deck aft bar.
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Lifesaving
Issued 14 September 2000
Resolved
For rescue boats: mouse shackles, renew painters, perform weight test (1.1 x normal load).
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Electrical
Issued 14 September 2000
Resolved
Properly install electrical cable at rescue boat winch.
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Lifesaving
Issued 14 September 2000
Resolved
Recharge and hydro test SCBA bottles in the gray cases.
Condition: Unknown
Due 14 October 2000
Resolved 6 November 2000
Unknown
Issued 12 September 2000
Resolved
The vessel must complete a deadweight survey as per required by MSC tech note 4-95.
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Engineering
Issued 25 July 2000
Resolved
PRIOR TO RESUMING NORMAL UNDERWAY OPERATIONS WITH PASSENGERS, PROVE PROPER OPERATION OF THE STARBOARD MAIN DIESEL ENGINE TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 August 2000
Resolved 26 July 2000
Accommodation/Occupational Safety
Issued 12 June 2000
Resolved
CLEAN THE DECK AND DRAINS OF THE 2ND DECK BAR.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Fire Fighting
Issued 12 June 2000
Resolved
CLEAN ALL SMOKE DETECTORS IN PASSENGERS SPACES.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Accommodation/Occupational Safety
Issued 12 June 2000
Resolved
CLEAN THE DECK UNDER THE COUNTER AT 1ST DECK AFT BAR.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Construction/Loadline
Issued 14 March 2000
Resolved
PROVE WATERTIGHT INTEGRITY OF MAIN DECK WHERE "HILTI" PENETRATIONS HAVE BEEN MADE.
Condition: Unknown
Due 14 March 2000
Resolved 14 March 2000
Electrical
Issued 14 March 2000
Resolved
PROPERLY LABEL AND UPDATE POWER PANELS THROUGHOUT THE VESSEL. VERIFY SPACE BREAKER USAGE.
Condition: Unknown
Due 14 March 2000
Resolved 14 March 2000
Lifesaving
Issued 14 December 1999
Resolved
REORGANIZE AND REMOVE ALL ELECTRICAL FIRE HAZARDS IN THE PHONE ROOM.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Accommodation/Occupational Safety
Issued 14 December 1999
Resolved
RECONNECT ALL EXHAUST DUCTING TO EXHAUST FANS ON ALL DECKS.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Fire Fighting
Issued 14 December 1999
Resolved
REPAIR FIRE DAMPER #2 TO PROPER OPERATING CONDITION.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Electrical
Issued 12 November 1999
Resolved
MAKE PROPER REPAIRS OF #1 GENSET AND/OR SWITCHBOARD. THE VESSEL SHALL NOT BE OPERATED UNLES AT LEAST (2) OF HE SHIP SERVICE GENSETS ARE AVAILABLE.
Condition: Unknown
Due 9 December 1999
Resolved 22 November 1999
Navigation
Issued 22 October 1999
Resolved
Renew or repair port side rudder stock bearing.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Electrical
Issued 18 October 1999
Resolved
Open and make ready for inspection all electrical wire cable runs and deckpenetraions on 3rd deck. Cable installation and penetrations are to be presented for examination to verify proper installation in accordence withapproved procedures.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Electrical
Issued 18 October 1999
Resolved
The gaming machines at aft (4 machines) of station 20 and the forward (4 machines) of station 3 are to remain shutdown until elec. wires are properly installed.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Fire Fighting
Issued 18 October 1999
Resolved
Make proposal on providing complete sprinkler coverage on the 3rd deck bar area and elsewhere on 3rd deck as necessary.
Condition: Unknown
Due 18 October 1999
Resolved 18 October 1999
Fire Fighting
Issued 13 September 1999
Resolved
CONDUCT DRILLS WITH NON-MARINE PERSONNEL AND DOCUMENT SAME WITH NON-MARINE PERSONNEL PARTICIPATION ON DAY AND NIGHT SHIFTS A MINIMUM OF 4 TIMES PER WEEK, PER SHIFT.
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Construction/Loadline
Issued 13 September 1999
Resolved
LABEL ALL TANK TOPS, SOUNDING TUBES, VALVE CROSSOVERS/CUTOUTS IN HOLD DECK.
Condition: Unknown
Due 13 October 1999
Resolved 20 September 1999
Lifesaving
Issued 13 September 1999
Resolved
REMOVE OIL/OILY SUBSTANCE FROM UNDER STARBOARD MDE.
Condition: Unknown
Due 18 September 1999
Resolved 20 September 1999
Lifesaving
Issued 13 September 1999
Resolved
SECURE DECK PLATES IN ENGINE ROOM, EOS/GENERATOR ROOM.
Condition: Unknown
Due 13 September 1999
Resolved 13 September 1999
Lifesaving
Issued 13 September 1999
Resolved
REPAIR LIFE JACKET BOX, PORT SIDE FORWARD ON THE MAIN DECK.
Condition: Unknown
Due 18 October 1999
Resolved 20 September 1999
Lifesaving
Issued 13 September 1999
Resolved
REMOVE ALL PLASTIC GARBAGE CANS AND REPLACE WITH STEEL.
Condition: Unknown
Due 18 September 1999
Resolved 20 September 1999
Lifesaving
Issued 13 September 1999
Resolved
STENCIL VESSEL NAME ON RESCUE BOAT PFD'S AND MUSTANG SUITS.
Condition: Unknown
Due 18 September 1999
Resolved 20 September 1999
Engineering
Issued 13 September 1999
Resolved
PROVIDE DOCUMENTATION AND APPROVAL LETTER FOR OVERSPEED SHUTDOWN SOLENOIDS ON ALL SSDG'S REGARDING CHANGE/MODIFICATION.
Condition: Unknown
Due 13 October 1999
Resolved 20 September 1999
Fire Fighting
Issued 13 September 1999
Resolved
PROVIDE WRITTEN PROPOSAL TO ADDRESS FIREFIGHTING PROTECTION, ADDRESSING_x001C_ SHORE SIDE ASSISTANCE AND WATERSIDE ASSISTANCE.
Condition: Unknown
Due 13 September 1999
Resolved 13 September 1999
Engineering
Issued 13 September 1999
Resolved
LABEL GENERATOR ROOM FUEL CUTOUT VALVE ON MAIN DECK BY THE #2 COLUMN ON THEPORT SIDE. PLACE T-WRENCH BY CUTOUT.
Condition: Unknown
Due 13 October 1999
Resolved 20 September 1999
Electrical
Issued 13 September 1999
Resolved
INSTALL A REMOTE START SWITCH FOR EMERGENCY FIRE PUMP ON BRIDGE.
Condition: Unknown
Due 29 October 1999
Resolved 14 September 1999
Lifesaving
Issued 13 September 1999
Resolved
PLACE ELECTRICAL MATTING IN FRONT OF SWITCHBOARD. CURRENT MATTING DOES NOT EXTEND ALL THE WAY ACROSS IN FRONT OF CIRCUIT BREAKER PANEL.
Condition: Unknown
Due 18 September 1999
Resolved 20 September 1999
Construction/Loadline
Issued 13 September 1999
Resolved
PROVE PROPER OPERATION OF INDICATOR FOR LIMIT SWITCH IN EOS ON WATERTIGHT DOOR.
Condition: Unknown
Due 18 September 1999
Resolved 14 September 1999
Fire Fighting
Issued 13 September 1999
Resolved
PROVE PROPER OPERATION OF CO2 FAN CUTOUT PRESSURE SWITCH FOR LIQUOR DISPENSING ROOM.
Condition: Unknown
Due 18 September 1999
Resolved 20 September 1999
Accommodation/Occupational Safety
Issued 13 September 1999
Resolved
PREPARE ALL BAR AREAS FOR INSPECTION. SHOULD BARS NOT PASS INSPECTION,_x001C_ THEY WILL BE SUBJECT TO POSSIBLE CLOSURE.
Condition: Unknown
Due 18 September 1999
Resolved 20 September 1999
Construction/Loadline
Issued 13 September 1999
Resolved
PROVE PROPER OPERATION OF WATERTIGHT DOOR NO. 5.
Condition: Unknown
Due 13 October 1999
Resolved 14 September 1999
Documentation
Issued 16 June 1999
Resolved
PROVIDE FIRELOAD CALCULATIONS FOR ALL CASINO SPACES.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Fire Fighting
Issued 16 June 1999
Resolved
REPAIR FIRE DAMPER PULL SYSTEM OUTSIDE SURVIELLANCE ROOM.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Fire Fighting
Issued 16 June 1999
Resolved
RELOCATE MANUAL PULL STATION ON MAIN DECK PORTSIDE AFT TO A CONSPICUOUS LOCATION AND LABEL.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Documentation
Issued 16 June 1999
Resolved
SUBMIT MODIFICATION PROPOSAL TO MSO NEW ORLEANS FOR APPROVAL ON ALL ONGOINGPROJECTS. ALL WORK CONDUCTED PRIOR TO APPROVAL IS DONE AT RISK OF POSSIBLE REMOVAL IF PROPOSAL IS DISSAPPROVED.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Lifesaving
Issued 16 June 1999
Resolved
PROVE PORPER OPERATION OF GENERAL ALARM BELL IN HARD COUNT.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Electrical
Issued 16 June 1999
Resolved
PROPERLY PACK ALL DECK ELECTRICAL PENETRATIONS IN WAY OF SLOT MACHINE BANKS.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Electrical
Issued 16 June 1999
Resolved
INSTALL METAL BANDING ON ALL ELECTRICAL WIRE RUNS ON 3RD DECK AND ALL OTHERAREAS BEING REMODELED.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Electrical
Issued 16 June 1999
Resolved
PROVE PROPER OPERATION OF ALL SSDG REVERSE POWER RELAYS.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Lifesaving
Issued 16 June 1999
Resolved
FREE UP STANTIONS AT PORT AFT LIFE RAFT STATION.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Lifesaving
Issued 8 March 1999
Resolved
REPLACE FORWARD AND AFT RESCUE BOAT WINCH CABLES.
Condition: Unknown
Due 18 March 1999
Resolved 22 March 1999
Fire Fighting
Issued 8 March 1999
Resolved
RELOCATE FIRE STATION #19 OUTSIDE OF RESTRICTED AREA.
Condition: Unknown
Due 8 April 1999
Resolved 22 March 1999
Lifesaving
Issued 8 March 1999
Resolved
TROUBLESHOOT/REPAIR/REPLACE GENERAL ALARM BELL IN SOFT COUNT.
Condition: Unknown
Due 18 March 1999
Resolved 22 March 1999
Electrical
Issued 14 December 1998
Resolved
INSTALL CLOSURE PLATES TO ALL AIR CONDITIONING ELECTRICAL CONTROLLER BOXES IN OVERHEAD. REMOVE ALL WIRE NUTS AND PROPERLY CRIMP.
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Electrical
Issued 15 September 1998
Resolved
On the bridge control panel, determine what the green lighted button and associated audible alarm go to and on corresponding engine room control panel the red lighted button and audible go to and label same.
Condition: Unknown
Due 22 September 1998
Resolved 21 October 1998
Lifesaving
Issued 15 September 1998
Resolved
Replace or renew retro-reflective tape on life rings where worn, faded or missing as discussed.
Condition: Unknown
Due 22 September 1998
Resolved 21 October 1998
Construction/Loadline
Issued 15 September 1998
Resolved
Make ready and demonstrate forward most bilge suction as discussed.
Condition: Unknown
Due 22 September 1998
Resolved 21 October 1998
Unknown
Issued 15 September 1998
Resolved
Clean under and behind concession areas on forward main deck and third decklocations and make available for inspection.
Condition: Unknown
Due 22 September 1998
Resolved 21 October 1998
Construction/Loadline
Issued 15 June 1998
Resolved
ADJUST WATERTIGHT DOORS TO ENSURE PROPER OPERATION. ENSURE ALL DOGS PROPERLY SEAT AND DOORS PROVIDE PROPER SEAL.
Condition: Unknown
Due 19 June 1998
Resolved 7 July 1998
Navigation
Issued 15 June 1998
Resolved
ADJUST STARBOARD RUDDER STOP SO THAT THE RUDDER STOPS MOVING BEFORE STRIKING THE HARD STOP.
Condition: Unknown
Due 19 June 1998
Resolved 7 July 1998
Lifesaving
Issued 15 June 1998
Resolved
INCREASE DANGER MARKING IN PORT MENS HEAD STOREROOM AROUND THE STEERING COMPARTMENT ESCAPE HATCH. THIS MARKING SHOULD BE SUFFICIENT TO PREVENT MATERIALS/BUCKETS FROM INTERFERING WITH THE HATCH OPENING.
Condition: Unknown
Due 19 June 1998
Resolved 7 July 1998
Accommodation/Occupational Safety
Issued 15 June 1998
Resolved
REPLACE B-ZERO BULKHEAD FROM CORRIDOR TO SURVIELLANCE ROOM OR, PROPOSE ALTERNATE RESOLUTION.
Condition: Unknown
Due 19 June 1998
Resolved 7 July 1998
Documentation
Issued 16 March 1998
Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Fire Fighting
Issued 16 March 1998
Resolved
PROVIDE A BLOCK DIAGRAM OF THE CO2 SYSTEM AT EACH BOTTLE STATION.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Accommodation/Occupational Safety
Issued 16 March 1998
Resolved
CLEAN AND SANITIZE ALL BAR AREAS AND DELI AREAS.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Electrical
Issued 16 March 1998
Resolved
REPAIR/REPLACE GENSET TACHOMETER.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Lifesaving
Issued 16 March 1998
Resolved
SECURE VENDING MACHINES AND APPLIANCES TO BULKHEADS AS APPLICABLE.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Electrical
Issued 29 September 1997
Resolved
Prove proper operation of #1 ship service genset to the satisfaction of theattending Marine Inspector.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Electrical
Issued 15 September 1997
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL SHUTDOWNS ON ALL SHIPS SERVICE AND EMERGENCY GENERATORS.
Condition: Unknown
Due 22 September 1997
Resolved 22 September 1997
Lifesaving
Issued 15 September 1997
Resolved
RELOCATE GENERAL ALARM SIGN IN VAULT FROM BEHIND CABINET.
Condition: Unknown
Due 22 September 1997
Resolved 22 September 1997
Lifesaving
Issued 15 September 1997
Resolved
REPAIR GENERAL ALARM BELL OUTSIDE SLOT MANAGERS OFFICE.
Condition: Unknown
Due 22 September 1997
Resolved 22 September 1997
Electrical
Issued 15 September 1997
Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP ON EMERGENCY GENERATOR.
Condition: Unknown
Due 22 September 1997
Resolved 22 September 1997
Engineering
Issued 15 September 1997
Resolved
PROVE PROPER OPERATION OF OWS.
Condition: Unknown
Due 22 September 1997
Resolved 22 September 1997
Construction/Loadline
Issued 15 September 1997
Resolved
REMOVE PAINT FROM GASKETS ON ALL WATERTIGHT DOORS.
Condition: Unknown
Due 22 September 1997
Resolved 22 September 1997
Fire Fighting
Issued 16 June 1997
Resolved
REPAIR A-60 INSULATION IN ALL WATER CLOSETS ON ALL DECKS.
Condition: Unknown
Due 16 June 1997
Resolved 16 June 1997
Construction/Loadline
Issued 16 June 1997
Resolved
PROVE PROPER OPERATION OF ALL AUTOMATIC WATERTIGHT DOORS IN HOLD DECK.
Condition: Unknown
Due 16 June 1997
Resolved 16 June 1997
Accommodation/Occupational Safety
Issued 16 June 1997
Resolved
RENEW LOCKING ARRANGEMENTS TO SECURITY CONTROLLED SPACES IN HOLD DECK IN ORDER TO ENABLE OCCUPANTS TO EGRESS FROM SPACE WITHOUT SECURITY PERSONNEL ASSISTANCE.
Condition: Unknown
Due 16 June 1997
Resolved 16 June 1997
Electrical
Issued 16 June 1997
Resolved
PROPERLY BAND HORIZONTAL WIRE RUNS IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 16 June 1997
Resolved 16 June 1997
Fire Fighting
Issued 25 March 1997
Resolved
SUBMIT REVISED DRAWING OF SPRINKLER SYSTEM PIPING.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Fire Fighting
Issued 11 March 1997
Resolved
SUBMIT REVISED DRAWING OF SPRINKLER SYSTEM PIPING.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Accommodation/Occupational Safety
Issued 11 March 1997
Resolved
IMPROVE AND MAINTAIN SANITARY CONDITIONS BEHIND ALL BARS AND IN BEVERAGE COOLERS.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Fire Fighting
Issued 11 March 1997
Resolved
HYDRO TEST MODIFICATIONS TO SPRINKLER SYSTEM (1 1/2 X MAWP FOR 2 HOURS).
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Lifesaving
Issued 16 January 1997
Resolved
VESSEL TO REMAIN MOORED DOCKSIDE AT CATFISH TOWN MOORINGS UNTIL NEW COAST GUARD APPROVED RESCUE BOATS ARE INSTALLED AND TESTED TO THE SATISFACTION OFTHE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 22 January 1997
Resolved 21 January 1997
Lifesaving
Issued 16 January 1997
Resolved
ENSURE RESCUE BOATS ARE APPROVED UNDER 46 CFR 160.156 AND IN COMPLIANCE WITH 46 CFR 199.176(a) AND 199.160 OR REPLACE IN KIND.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Electrical
Issued 18 December 1996
Resolved
REWIRE ELECTRICAL RUN FROM DISTRIBUTION PANEL TO EMERGENCY GENERATOR ON AFTBULKHEAD OF EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Lifesaving
Issued 18 December 1996
Resolved
PROPERLY SECURE ALL ATM AND VENDING MACHINES TO BULKHEAD THROUGHOUT VESSEL.
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Accommodation/Occupational Safety
Issued 18 December 1996
Resolved
REMOVE EXCESS FLAMMABLE AND COMBUSTIBLE MATERIALS FROM FWD ENGINE ROOM, FWDSTORES, AND STBD STAIRTOWER HOLD DECK LEVEL.
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Fire Fighting
Issued 18 December 1996
Resolved
SUBMIT PROPOSAL FOR WINDOW INSTALLATION IN B-0 BULKHEAD OF SLOT TRACKING OFFICE TO MSO NEW ORLEANS FOR APPROVAL.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Fire Fighting
Issued 16 September 1996
Resolved
CORRECT BACK-UP SPRINKLER PUMP INSTALLATION TO PREVENT ONE (1) CASUALTY FROM RENDERING MAIN SPRINKLER PUMP AND BACK-UP SPRINKLER PUMP INOPERABLE. SUBMIT PLANS TO MSO NEW ORLEANS FOR APPROVAL.
Condition: Unknown
Due 16 September 1996
Resolved 16 September 1996
Fire Fighting
Issued 17 June 1996
Resolved
PROVIDE MANUFACTURERS DOCUMENTATION OF USCG APPROVAL OF FIRE STOP CAULK.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Fire Fighting
Issued 17 June 1996
Resolved
PROVIDE APPROPRIATE NUMBER OF SPARE SPRINKLER HEADS IAW NFPA 13.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Fire Fighting
Issued 17 June 1996
Resolved
REMOVE SATELLITE CABINET FROM STARBOARD STAIRTOWER ON THE FOURTH DECK.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Electrical
Issued 17 June 1996
Resolved
PROPERLY BAND WIRES IN OVERHEARD AND VERTICAL RUNS IN ENGINEERING SPACES WITH METAL BANDS.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Fire Fighting
Issued 17 June 1996
Resolved
PROVIDE MANUFACTURERS DOCUMENTATION OF USCG APPROVAL FOR STRUCTURAL FIRE INSULATION OF THE CHILLER ROOM.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Construction/Loadline
Issued 18 March 1996
Resolved
INSTALL A OPA-90 POLLUTION PLACARD AT BILGE/BALLAST OVBD DISCHARGE VALVE, STBD SIDE, MAIN GENERATOR ROOM.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 18 March 1996
Resolved
MAKE PROPER REPAIRS TO EMERGENCY LIGHT TEST SWITCH IN STEERING ROOM SPACE.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 18 March 1996
Resolved
LABLE PORT SIDE LADDER, IN STEERING ROOM SPACE, "EMERGENCY ESCAPE".
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 18 March 1996
Resolved
LABLE STBD SIDE LADDER, IN THE STEERING ROOM SPACE "DO NOT USE IN AN EMERGENCY".
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Construction/Loadline
Issued 18 December 1995
Resolved
Reattach drop ceiling in liquor store room overhead.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Electrical
Issued 18 December 1995
Resolved
Repair stuffing tubes and hole behind bar on second deck.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Fire Fighting
Issued 18 December 1995
Resolved
Replace or repair metal screen guard for fixed CO2 system components located forward of main eng.room. The guard installed at present is loose.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Accommodation/Occupational Safety
Issued 18 December 1995
Resolved
Fasten down eight gaming tables on the third deck and second deck.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Electrical
Issued 19 September 1995
Resolved
Provide documentation that your food warmers in the Butlers Pantry galley are UL approved.
Condition: Unknown
Due 19 September 1995
Resolved 19 September 1995
Documentation
Issued 19 September 1995
Resolved
ENSURE CHEMICAL TESTING PROGRAM COMPLIES WITH 46 CFR PART 16 SPECIFICALLY PART 16.500. COMPLETE FORM (B) AND RETURN TO THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 October 1995
Resolved 10 October 1995
Fire Fighting
Issued 19 September 1995
Resolved
SUBMIT RESULTS OF ANNUAL PUMP TEST IAW NFPA 25 FOR FIRE/SPRINKLER PUMPS.
Condition: Unknown
Due 19 September 1995
Resolved 19 September 1995
Engineering
Issued 19 September 1995
Resolved
Make permanent repairs to the cooling water piping on the stbd. MDE raw water cooling system.
Condition: Unknown
Due 19 October 1995
Resolved 10 October 1995
Engineering
Issued 17 August 1995
Resolved
MAKE CORRECTIVE REPAIRS AND PROVE PROPER OPERATION OF THE PORT MAIN DIESEL ENGINE. PROPER OPERATION IS TO BE WITNESSED BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 21 August 1995
Resolved 18 August 1995
Engineering
Issued 29 June 1995
Resolved
Provide for the draining of the propeller shaft seal containment boxes and both P/S.
Condition: Unknown
Due 29 July 1995
Resolved 7 July 1995
Electrical
Issued 29 June 1995
Resolved
Place electrical metal securing bands on electrical cables in the chiller room on the aft starboard bulkhead and in the generator room on the fwd stbd bulkhead.
Condition: Unknown
Due 29 July 1995
Resolved 7 July 1995
Electrical
Issued 29 June 1995
Resolved
Properly stow or remove dead ended wires inside paddle wheel control cabinets in main motor room.
Condition: Unknown
Due 29 July 1995
Resolved 7 July 1995
Engineering
Issued 20 March 1995
Resolved
Make proper repair to STBD. paddlewheel motor shaft seal to prevent leaking.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Construction/Loadline
Issued 20 March 1995
Resolved
Label all vents on main deck.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Construction/Loadline
Issued 20 March 1995
Resolved
Change alarms on Class I WTD's in hold area to monitor dog, indicating thatdoor is closed and fully dogged.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Fire Fighting
Issued 20 March 1995
Resolved
Prove fire load calculations include plastic trash cans and theatre ropes around pit areas.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Construction/Loadline
Issued 20 March 1995
Resolved
Make adjustment to QAWTD #6 where it will completely close.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Construction/Loadline
Issued 20 March 1995
Resolved
Mark all emergency escape hatches from inside space.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Fire Fighting
Issued 20 March 1995
Resolved
Submit proposal to enclose CO2 bottles in hold spaces in cabinets, guards, etc. to prevent tampering with actuation devices and cylinders, time delays, stop valves, flex loops and tanks.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Electrical
Issued 20 March 1995
Resolved
Remove excess speaker/video cable from EOS Ovhd.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Fire Fighting
Issued 20 March 1995
Resolved
Label all fire dampers IAW 46 CFR.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Fire Fighting
Issued 20 March 1995
Resolved
Label all sprinkler test connections IAW 46 CFR.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Electrical
Issued 3 January 1995
Resolved
PROPERLY TERMINATE UNUSED WIRING IN SYSTEM 3 FIRE DETECTION CABINETS ON BRIDGE.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Fire Fighting
Issued 3 January 1995
Resolved
PROVIDE SPRINKLER SYSTEM MANUSL THAT IS VESSEL SPECIFIC AND IN ACCORDANCE WITH 46 CFR 76.25-35(j).
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Engineering
Issued 3 January 1995
Resolved
PROVE PROPER OPERATION OF OVERSPEED SHUTDOWNS TO THE FOLLOWING: #1,#2,#3 S/S GENERATORS AND #1 & #2 MAIN DIESEL ENGINES.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Lifesaving
Issued 3 January 1995
Resolved
SUBMIT PROPOSAL TO COGNIZANT OCMI FOR MODIFICATION TO CURRENT RESCUE BOATS & DAVIT INSTALLATIONS TO ALLOW BETTER RESPONSE TIME IN EMERGENCY SITUATION.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Engineering
Issued 3 January 1995
Resolved
MAKE PROPER/PERMANENT REPAIRS TO STBD PADDLE WHEEL DRIVE MOTOR COMPUTER ENCODER CONTROL SYSTEM.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Electrical
Issued 3 January 1995
Resolved
MAKE PROPER/PERMANENT REPAIRS TO #2 S/S GEN ENGINE OVERSPEED/SHUTDOWN SYSTEM AND PROVE PROPER OPERATION.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Electrical
Issued 3 January 1995
Resolved
INSTALL COVERS OVER OPENINGS INSIDE ELECTRICAL PANELS E401 AND L104.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995