← All vessels
ALTAIR
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named ALTAIR
ALTAIR is a 1979 freight ship. The Coast Guard has recorded 20 inspections since 1998, most recently in October 2005, along with 35 deficiencies and 4 operational controls.
Records from 1998 to 2005. Most recent: inspection, 4 October 2005.
- Built
- 1979
- Last inspected
- 4 October 2005
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 35 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7813602 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FMD7
408586
Flag
LIBERIA
—
Maury page id
psix-408586
Inspections, by type
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it9062 - Convention (Subpart B), Net Ton
23284 - Dead Weight, Ton
31363 - Displacement, Ton
16325 - Convention (Subpart B), Gross Ton
23284 - Dead Weight, Ton
31363 - Displacement, Ton
16325 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
4 October 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2508538
26 September 2005
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2501935
23 July 2005
PII Safety Exam · Spot Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2423866
3 July 2005
MARPOL Annex I Examination · ISPS II Exam · NPV Safety Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2411177
19 April 2005
PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2337019
17 April 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2348216
14 April 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2334329
12 February 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2292074
16 August 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2167572
15 August 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2166527
26 March 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2032062
6 December 2002
Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1715454
6 July 2002
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1642543
14 February 2002
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1486727
17 January 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1478022
9 May 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 289804
11 January 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 273580
26 August 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 432164
16 December 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 423735
10 December 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 423477
Deficiency record · 35
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 2 July 2005
Resolved
The vessel does not have a vessel specific Ballast Water Management plan onboard.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 July 2005
Resolved
THE OILY WATER SEPERATOR (OWS) 3-WAY VALVE DID NOT OPERATE PROPERLY.
Navigation › Piloting/Steering › Gyro Compass
Issued 16 August 2004
Resolved
13Aug04: Recieved inbound deviation request due to inoperable gyro compass. Repair prior to departure from port.
Engineering › Sea-water System (primary cooling)
Issued 14 February 2002
Resolved
No. 1 Generator cooling water line was ruptured and leaking. See attached picture. LEGACY COMPONENT DESC: Piping
Engineering › Sea-water System (primary cooling)
Issued 14 February 2002
Resolved
No. 1 Seawater cooling pump for main generator is leaking excessively. See attached picture. LEGACY COMPONENT DESC: Pump
Deck/Cargo › Ballast
Issued 14 February 2002
Resolved
Cement patch was found on the main ballast line by way of No. 2 ballast pump. See attached picture. LEGACY COMPONENT DESC: Piping
Engineering › Steering Gear System
Issued 14 February 2002
Resolved
Numerous leaks were found on the Steering gear system with reservoirs low and excessive amounts of hydraulic oil in the containment. See attached picture.
Fire Fighting › Combustible Materials
Issued 14 February 2002
Resolved
Execessive amount of oily water was found in the bilges.
Engineering › Sea-water System (primary cooling)
Issued 17 January 2002
Resolved
CEMENT PATCH ON MAIN COOLING LINE FROM MAIN ENGINE COOLING PUMP. LEGACY COMPONENT DESC: Piping
Fire Fighting › International Shore Connection
Issued 17 January 2002
Resolved
INTERNATIONAL SHORE CONNECTION MISSING PARTS.
Construction/Loadline › Hull
Issued 17 January 2002
Resolved
WASTED PORT BULKWORK MAIN DECK FRAMING ESPECIALY IN AMIDSHIPS AREA.
Construction/Loadline › Markings
Issued 17 January 2002
Resolved
LOAD-LINE MARK PORT SIDE NOT PROPERLY PAINTED. LEGACY COMPONENT DESC: Load Line Mark
Navigation
Issued 26 August 1999
Resolved
Update Notice to Mariner inventory and ensure complete chart corrections are made in accordance with 33CFR164.33(a)(1)(ii), no later than 26SEP99.
Navigation
Issued 10 December 1998
Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY STEERING OPERATION. SOLAS 60 II/29
Lifesaving
Issued 10 December 1998
Resolved
PROVIDE MAINTENANCE LOGS FOR ALL LIFESAVING EQUIPMENT. SOLAS 74(AMENDED)III/19.3_x001C_ _x001C_ _x001C_
Fire Fighting
Issued 10 December 1998
Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP. SOLAS 74 (AMENDED)II-2/21
Lifesaving
Issued 10 December 1998
Resolved
DEMONSTRATE PROPER ABANDON SHIP DRILL TO THE SATISFACTION OF U. S. COAST GUARD. SOLAS 74 (AMENDED)III/18.3_x001C_ _x001C_ _x001C_
Lifesaving
Issued 10 December 1998
Resolved
REMOVE PAINTS AND THINNERS STORED IN PARTS STORAGE ROOM. SOLAS 74(AMENDED)I/11(a)_x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 10 December 1998
Resolved
REPAIR AS ORIGINAL HANDRAIL ON CAT WALK AROUND BOILER. ILLC_x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 10 December 1998
Resolved
RENEW AS ORIGINAL GASKETS ON FIRE HOSES, NOZZLES THROUGHOUT VESSEL. SOLAS 74(AMENDED) II-2/21
Fire Fighting
Issued 10 December 1998
Resolved
PROVIDE MAINTENANCE LOGS FOR ALL FIRE FIGHTING EQUIPMENT. SOLAS 74(AMENDED)II-2/20
Navigation
Issued 10 December 1998
Resolved
PROPERLY LOG PRE-ARRIVAL/DEPARTURE TESTS PRIOR TO DEPARTURE AND RETURN TO U.S. PORT.
Accommodation/Occupational Safety
Issued 10 December 1998
Resolved
RENEW AS ORIGINAL HANDRAIL LEADING TO HOSPITAL SPACE. ILLC
Lifesaving
Issued 10 December 1998
Resolved
RENEW AS ORIGINAL FRESHWATER EVAPORATOR PIPING IN ENGINE ROOM. SOLAS 74(AMENDED)I/11(a)_x001C_ _x001C_ _x001C_
Lifesaving
Issued 10 December 1998
Resolved
CLEAN AND REPAIR LEAKING OIL AROUND BOILER EXHAUST PIPING. SOLAS 74 (AMENDED)I/11(a)_x001C_ _x001C_ _x001C_
Fire Fighting
Issued 10 December 1998
Resolved
DEMONSTRATE PROPER FIRE DRILL TO THE SATISFACTION OF U.S. COAST GUARD. SOLAS 74 (AMENDED)III/18.3_x001C_ _x001C_ _x001C_
Lifesaving
Issued 10 December 1998
Resolved
PROVIDE ALL EMERGENCY INSTRUCTIONS AND TRAINING MANUALS IN THE LANGUAGE OF THE CREW (UKRAINIAN). SOLAS 74(AMENDED)III/18
Lifesaving
Issued 10 December 1998
Resolved
RENEW AS ORIGINAL LEAKING SEWAGE PIPE OVERHEAD PORT SIDE, FORWARD ENGINE ROOM. SOLAS 74 (AMENDED) I/11(a)_x001C_ _x001C_ _x001C_
Engineering
Issued 10 December 1998
Resolved
DEMONSTRATE PROPER OPERATION OF OILY WATER SEPARATOR AND ALARM. MARPOL 73/78 ANNEX 1/16_x001C_ _x001C_ _x001C_
Fire Fighting
Issued 10 December 1998
Resolved
PROPERLYT STORE COMPLETE INTERNATIONAL SHORE CONNECTION IN LOCATION INDICATED ON FIRE CONTROL PLAN. SOLAS 60 II/56.8
Documentation
Issued 10 December 1998
Resolved
PROVIDE FLAG STATE ENDORESEMENTS FOR ALL OFFICERS HOLDING UKRANIAN AND RUSSIAN LICENSES. STCW 78 II/4
Lifesaving
Issued 10 December 1998
Resolved
PROVIDE ONBOARD EIGHT SERVICEABLE LIFERING BUOYS. SOLAS 60 III/37
Lifesaving
Issued 10 December 1998
Resolved
REPLACE WEEKLINK TO HYDROSTATIC RELEASE FOR EPIRB. SOLAS 74(AMENDED)III/7.6.4_x001C_ _x001C_ _x001C_
Lifesaving
Issued 10 December 1998
Resolved
PROPERLY SERVICE TWO LIFERAFTS AND PROVIDE SERVICE REPORT TO U.S. COAST GUARD. SOLAS 74(AMENDED)III/19.8
Lifesaving
Issued 10 December 1998
Resolved
PROVIDE NEW/SERVICEABLE POORT SIDE EMBARKATION LADDER. SOLAS 60 III/19(a)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.