Records from 1995 to 2010. Most recent: operational control imposed, 17 December 2010.
Inspection history · 17
17 December 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3909133
17 December 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3912257
22 March 2006
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2607421
27 January 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2574626
9 September 2005
NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2488324
9 August 2004
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2160585
13 February 2003
Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1744180
7 August 2002
Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1657987
22 December 2001
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1476317
6 September 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 293322
29 October 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 434239
20 April 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 427456
20 April 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 492348
20 June 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 416905
21 April 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 414785
21 February 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 388162
3 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 373917
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 17 December 2010
Resolved
0740 - Pumps - Emergency fire pump inoperable. PSCO observed the electric motor for the emergency fire pump trip off line during operation which appeared to be an amperage overload - SOLAS 74a II-2/10
Action required: 705 - Other - as specified
Due 17 December 2010
Resolved 21 December 2010
Resolution: Received, reviewed and accepted class report from CCS stating the circuit of the control box of the electric motor for the emergency fire pump was examined carefully and power switch and time-lag relay unit had been renewed. Pump tested and found sat.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 17 December 2010
Resolved
1420 - Cleanliness of the engine room - PSCO discovered numerous excessive oil and fuel leaks on the main engine and generators. Crew has placed several rags and catch buckets to contain the leaks, rags are soaked with oil and catch buckets are overflowing.- SOLAS 74a II-2/4
Action required: 705 - Other - as specified
Due 17 December 2010
Resolved 21 December 2010
Resolution: Received, reviewed and accepted class report from CCS stating the leaks were repaired and all standing oil and catch buckets removed.
Engineering › Diesel Engine (propulsion-direct drive) › Charge Air Cooling
Issued 17 December 2010
Resolved
1499 - Other prop. aux. mach. - PSCO discovered the bottom of the charge air cooler to the main engine has wasted away and is seeping cooling sea water out. The failure of this equipment will result in catastrophic failure if the main engine. Temporary repair were attempted to no avail. SOLAS 74a II-1/26
Action required: 705 - Other - as specified
Due 17 December 2010
Resolved 21 December 2010
Resolution: Received, reviewed and accepted class report from CCS stating the bottom plate and end plate of two charge air coolers to the main engine inspected and bolts on the plate fixed and found in normal condition. Water tightness test satisfactory.
Engineering › Lubricating Oil Storage/Transfer System › Valve
Issued 17 December 2010
Resolved
0999 - PSCO discovered excessive oil leaks on the controls for the ballasting valves aft of cargo hold #1. SOLAS 74a II-2/4
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2010
Resolved 21 December 2010
Resolution: Received, reviewed and accepted class report from CCS stating the tie-ins of the hydraulic oil pipes for the ballasting control valves aft of No.1 cargo hold fixed and cleaned and found in order.
Navigation › Collision/Grounding Avoidance › Radar
Issued 17 December 2010
Resolved
1530 - Radar - Master reported one of his marine radar systems to be inoperable to the Coast Guard. - 33CFR165.35
Action required: 705 - Other - as specified
Due 17 December 2010
Resolved 17 December 2010
Resolution: Technician arrived on board during PSC exam, repaired inoperable radar and provided a tech report to the PSCO attesting to satisfactory operation.
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 December 2001
Resolved
Replace out of date lifejacket lights. LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 August 2002
Resolution: All Lifejackets are in good condition with properly working lights attached.
Lifesaving
Issued 21 April 1998
Resolved
CONDUCT PROPER ABANDON SHIP DRILL IN ATTENDANCE OF U.S. COAST GUARD. SOLAS74 (Amended) III/18.3.4-3.9
Condition: Unknown
Due 21 April 1998
Resolved 22 April 1998
Lifesaving
Issued 21 April 1998
Resolved
PROVIDE PROPER UP TO DATE BATTERIES FOR LIGHTS ON LIFE PRESERVERS WITH ASSOCIATED EXPIRATION DATES. SOLAS 74 (Amended) I/30.3.
Condition: Unknown
Due 21 April 1998
Resolved 22 April 1998
Navigation
Issued 21 April 1998
Resolved
HAVE A RECOGNIZED REPAIR COMPANY SURVEY 3 CM RADAR FOR POTENTIAL PROBLEMS WITH CRT DISPLAY. SEND FAXED COPIES OF SURVEY REPORTS TO USCG MOBILE. SOLAS 74 (Amended) V/12(g).
Condition: Unknown
Due 21 April 1998
Resolved 22 April 1998
Fire Fighting
Issued 21 April 1998
Resolved
CONDUCT PROPER FIRE DRILL IN ATTENDANCE OF U.S. COAST GUARD. SOLAS 74 (Amended) III/18.3.10-3.13
Condition: Unknown
Due 21 April 1998
Resolved 22 April 1998
Electrical
Issued 21 April 1998
Resolved
PROVIDE PROPER LIGHTING IN WAY OF ENGINEROOM ESCAPE TRUNK AS PER SOLAS 74 II-1/43.2.2.1.
Condition: Unknown
Due 21 April 1998
Resolved 22 April 1998
Navigation
Issued 21 April 1998
Resolved
CLEAR PORT SIDELIGHT TO ENSURE LIGHT VISIBILITY AND RANGE IS NOT COMPROMISED AS PER INTERNATIONAL REGS. FOR PREVENTING COLLISIONS AT SEA, 1972 RULE 21(b) AND COLREGS RULE 21(b).
Condition: Unknown
Due 21 April 1998
Resolved 22 April 1998
Fire Fighting
Issued 21 April 1998
Resolved
PROVIDE PROPER INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL INSTALLATIONS/EQUIPMENT FOR FIGHTING AND CONTAINMENT OF FIRE. SOLAS 74 (Amended) II-2/20
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998