MAURY USCG vessel records Sign in
← All vessels

GEMINI

GEMINI is a 1967 freight ship. The Coast Guard has recorded 24 inspections since 1988, most recently in July 1995, along with 65 deficiencies and 3 operational controls.

Records from 1988 to 1995. Most recent: inspection, 8 July 1995.

Built
1967
Last inspected
8 July 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6721369 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
408635
Flag
MYANMAR (BURMA)
—
Maury page id
psix-408635

Inspections, by type

…with no type recorded24
Years with a record 4 calendar years (1988–1995)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it320 - Regulatory (Subpart C or D), Net Ton
1200 - Dead Weight, Ton
499 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

8 July 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 380260
3 July 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 380213
17 June 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 379637
4 May 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 704020
21 April 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 377530
30 March 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 377125
4 November 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 374739
14 October 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 704019
16 September 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 184878
10 August 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 704017
10 August 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 704018
30 June 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 368940
30 June 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 868732
29 June 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 70912
19 April 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 700417
15 April 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 365973
12 April 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 700418
9 April 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 365926
18 December 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2480
17 December 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355258
24 November 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 647188
4 November 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 471331
24 October 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 528239
26 June 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 324267

Deficiency record · 65

Documentation
Issued 17 June 1995 Resolved
PROVIDE FOLLOWING DOCUMENTS: LOADLINE, SAFETY RADIO, IOPP AND SAFETY EQUIPMENT.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Documentation
Issued 17 June 1995 Resolved
PROVIDE STATEMENT FROM FLAG STATE ADMINISTRATION ACCEPTANCE OF FOREIGN FLAGLIC.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Lifesaving
Issued 21 April 1995 Resolved
SOLAS_x001C_ VESSELS LIFEBOAT NOT IN COMPLIANCE WITH THE SOLAS SAFETY EQUIPMENT CERTIFICATE. THE LIFEBOAT NEEDS MAJOR OVERHAUL AND NEEDS TO BE EQUIPED WITH THE PROPER EQUIPMENT.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Electrical
Issued 21 April 1995 Resolved
SOLAS_x001C_ EMBARKATION LIGHTS ON THE PORT AND STRB SIDE NOT FUNCTING.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Lifesaving
Issued 21 April 1995 Resolved
SOLAS_x001C_ THE VESSEL HAD LIGHTS MISSING OR INOPERATIVE ON THE PORT, STBD, AND AFT RING BUOYS.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Lifesaving
Issued 21 April 1995 Resolved
SOLAS_x001C_ COVER FOR LIFEBOAT WINCH MISSING.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Electrical
Issued 21 April 1995 Resolved
SOLAS_x001C_ THE EMERGENCY GENERATOR INSTALLATION UNSATISFACTORY, THE ENGINE GOVERNOR ISNOT OPERATING PROPERLY AND THE AIR SUPPLY AND EXHAUST SYSTEM IS NOT PROPER.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Fire Fighting
Issued 21 April 1995 Resolved
SOLAS_x001C_ PAINT LOCKER UNSATISFACTORY, SEAL HOLE IN BULKHEAD WERE EMERGENCY_x001C_ GENERATOR EXHAUST REROUTED. PAINTS NOT STOWED PROPERLY.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Fire Fighting
Issued 21 April 1995 Resolved
SOLAS_x001C_ SERVICING REPORT FOR THE CO2 SYSTEM IN THE PAINT LOCKER SHOWES NO SIGN OF SERVICING.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Fire Fighting
Issued 21 April 1995 Resolved
SOLAS_x001C_ FIRE DAMPERS FOR ENGINE ROOM RUSTED.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Engineering
Issued 21 April 1995 Resolved
SOLAS_x001C_ MUSHROOM VENT COVERS/FANS ON TOP OF HOUSE NEAR STACK ARE WASTED.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Engineering
Issued 21 April 1995 Resolved
SOLAS_x001C_ PIPING FOR HEAT EXCHANGERS FOR MAIN DIESEL ENGINE IS WASTED AND PACHED IN PLACES WITH EPOXY.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Fire Fighting
Issued 21 April 1995 Resolved
SOLAS_x001C_ 3 FIRE HOSES ARE HOLED AND WASTED.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Documentation
Issued 21 April 1995 Resolved
VESSEL DID NOT HAVE A VALID IOPP CERTIFICATE ON BOARD.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Lifesaving
Issued 21 April 1995 Resolved
SOLAS_x001C_ THE VESSEL DID NOT HAVE AN APROVED SART (RADAR TRANSPONDER) ON BOARD.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Lifesaving
Issued 21 April 1995 Resolved
SOLAS_x001C_ THE PORT AND STARBOARD LIFERAFTS NEED SERVICING.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Electrical
Issued 21 April 1995 Resolved
SOLAS_x001C_ THE MACHINERY GUARDES ON THE PORT AND STARBOARD GENERATORS MISSING.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Engineering
Issued 21 April 1995 Resolved
RENEW/REPAIR OILY-WATER SEPARATING EQUIPMENT ONBOARD VESSEL.
Condition: Unknown
Due 29 April 1995
Resolved 18 May 1995
Fire Fighting
Issued 21 April 1995 Resolved
SOLAS_x001C_ THE BOAT NEEDS A SERVICING REPORT FOR THE FIXED HALON SYSTEM.
Condition: Unknown
Due 29 April 1995
Resolved 9 May 1995
Electrical
Issued 21 April 1995 Resolved
SOLAS_x001C_ THE HYDRAULIC PIPING SYSTEM OFF OF THE PORT GENERATOR HAS A CLUTCH AND IS DISCONNECTED AND IS INOERATIVE.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Deck/Cargo
Issued 21 April 1995 Resolved
SOLAS_x001C_ WASTED HYDRAULIC PIPING ON CARGO BOOM MACHINERY OFF OF FO'C'SLE.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Documentation
Issued 21 April 1995 Resolved
VESSEL DID NOT HAVE THE REQUIRED SOPEP ON BOARD.
Condition: Unknown
Due 18 June 1995
Resolved 18 June 1995
Fire Fighting
Issued 30 March 1995 Resolved
PROVIDE SERVICING REPORT FOR ENGINE ROOM FIXED HALON SYSTEM PRIOR TO RETURNTO U.S.WATERS.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Documentation
Issued 30 March 1995 Resolved
MAKE ONBOARD UP TO DATE NOTICE TO MARINERS CORRECTIONS TO CHART 11466 PRIOR TO RETURN TO U.S. WATERS([name withheld]).
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Accommodation/Occupational Safety
Issued 30 March 1995 Resolved
PERMANENTLY SECURE TWO MAIN DECK TOILETS WHEN IN U.S. WATERS AND PERMANENTLY PIPE DISCHARGE DIRECTLY TO MARINE SEWAGE DEVICE PRIOR TO RETURNTO U.S. WATERS.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Accommodation/Occupational Safety
Issued 30 March 1995 Resolved
PROVIDE RUNNING WATER TO MAIN DECK TOILETS FOR FLUSHING PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Documentation
Issued 30 March 1995 Resolved
PROVIDE MEDICAL CERTIFICATES FOR ALL CREWMWMBERS PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Construction/Loadline
Issued 30 March 1995 Resolved
PROVIDE EVIDENCE OF DRYDOCKING WITHIN PAST FIVE YEARS (DRYDOCK SURVEY/REPORT) PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Construction/Loadline
Issued 30 March 1995 Resolved
PROVIDE CALIBRATION REPORT FOR OILY WATER SEPARATOR CONTENT METER TO [name withheld] PRIOR TO RETURN TO U.S.WATERS.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Documentation
Issued 30 March 1995 Resolved
PROVIDE ONBOARD CURRENT YEAR(UP TO DATE) EDITION OF TIDE TABLES, COAST PILOT AND LIGHT LIST PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Deck/Cargo
Issued 30 March 1995 Resolved
PROVIDE DANGEROUS CARGO MANIFEST FOR ALL VEHICLES STOWED WITH FUEL. MAX FUEL ALLOWED IS 1/4 TANK PER VEHICLE, PRIOR TO DEPARTURE.
Condition: Unknown
Due 30 March 1995
Resolved 20 April 1995
Documentation
Issued 30 March 1995 Resolved
PROVIDE VALID COFR FOR VESSEL PRIOR TO DEPARTURE AND PROVIDE CERTIFICATE ONBOARD PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 30 March 1995
Resolved 20 April 1995
Electrical
Issued 30 June 1994 Resolved
Install missing light fixture globes located in the forepeak, machinery generator space, paint locker and crew's accomodations throught out vessel._x001C_
Condition: Unknown
Due 8 April 1995
Resolved 8 April 1995
Documentation
Issued 30 June 1994 Resolved
Provide a safe manning certificate from the vessel's class society.
Condition: Unknown
Due 8 April 1995
Resolved 8 April 1995
Fire Fighting
Issued 30 June 1994 Resolved
Replace 03 wasted valve handles at fire stations located on the stbd wx deck, main deck and aft of the superstructure.
Condition: Unknown
Due 1 July 1994
Resolved 8 August 1994
Navigation
Issued 30 June 1994 Resolved
Subj vessel was missing charts 11412, 11413 and 11414 required for transitting Tampa Bay.
Condition: Unknown
Due 1 July 1994
Resolved 8 August 1994
Construction/Loadline
Issued 30 June 1994 Resolved
Replace wasted/missing gaskets on w/t port covers on the stbd side and bithdoors on the 01 deck to stack access space.
Condition: Unknown
Due 1 July 1994
Resolved 8 August 1994
Construction/Loadline
Issued 30 June 1994 Resolved
Install dogs where missing on weathertight doors located on forepeak generator space and paint locker.
Condition: Unknown
Due 1 July 1994
Resolved 2 August 1994
Electrical
Issued 30 June 1994 Resolved
Provide a suitable battery box to secure generator service battery located in the forepeak.
Condition: Unknown
Due 1 July 1994
Resolved 2 August 1994
Navigation
Issued 15 April 1994 Resolved
CURRENT COPY OF U.S. COAST PILOT 4 NOT AVAILABLE.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Electrical
Issued 15 April 1994 Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR INCLUDING CHARGING UNIT FOR START BATTERIES.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Navigation
Issued 15 April 1994 Resolved
NAVIGATION CHARTS NOT PROPERLY CORRECTED.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Navigation
Issued 15 April 1994 Resolved
CURRENT DEVIATION TABLE NOT AVAILABLE FOR MAGNETIC COMPASS.
Condition: Unknown
Due 26 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 15 April 1994 Resolved
CONDUCT TEST OF VESSEL'S HORN; TEST NOT CONDUCTED DUE TO NO SHIPS SERVICE AIR AVAILABLE.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Lifesaving
Issued 15 April 1994 Resolved
TWELVE HAND ROCKET-PROPELLED PARACHUTE RED DISTRESS SIGNALS WERE FOUND TO BE WITH EXPIRED DATES.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Documentation
Issued 15 April 1994 Resolved
LICENSED OFFICERS DID NOT POSSES VALID CERTIFICATES OF COMPETENCY AS REQUIRED BY STCW REGULATION I/2.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Engineering
Issued 15 April 1994 Resolved
REPAIR AND PROVE PROPER OPERATION OF MAIN DIESEL ENGINE START AIR CONTROL VALVE.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Construction/Loadline
Issued 15 April 1994 Resolved
PROVE PROPER OPERATION OF BILGE SYSTEM BY TAKING SUCTION FROM FORWARD MOST BILGE SUCTION.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Engineering
Issued 15 April 1994 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Engineering
Issued 15 April 1994 Resolved
IDENTIFY SLUDGE TANK STANDARD DECK DISCHARGE CONNECTION.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Documentation
Issued 15 April 1994 Resolved
VALID CERTIFICATE OF INSPECTION OR EQUIVALENT INSPECTION DOCUMENTS ISSUED BY THE FLAG STATE NOT AVAILABLE.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Documentation
Issued 15 April 1994 Resolved
VESSEL NOT MINIMALLY MANNED WITH TWO LICENSED MATES AS REQUIRED BY TITLE 46USC 8301(a)(3).
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Fire Fighting
Issued 15 April 1994 Resolved
PROVIDE SERVICING REPORT FOR PAINT LOCKER AND ENGINE ROOM HALON SYSTEMS.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Construction/Loadline
Issued 15 April 1994 Resolved
COMPLETE PERMANENT REPAIRS TO CORROSION HOLES LOCATED IN THE AFTER CARGO HOLD BILGE WELLS SHELL PLATING.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Construction/Loadline
Issued 15 April 1994 Resolved
PROVIDE DECK MARK ON VESSEL HULL FOR LOADLINE MARKINGS.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Lifesaving
Issued 15 April 1994 Resolved
CONDUCT ANNUAL SERVICING OF 10 MAN INFLATABLE LIFERAFT.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Lifesaving
Issued 15 April 1994 Resolved
PROVIDE ONE ADULT TYPE I LIFE PRESERVER.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Fire Fighting
Issued 15 April 1994 Resolved
PROVE PROPER OPERATION OF PORT FIRE/BILGE/BALLAST PUMP.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Fire Fighting
Issued 15 April 1994 Resolved
PROVE PROPER OPERATION OF STBD. FIRE/GENERAL SERVICE PUMP; INSUFFICIENT PRESSURE @ 2.2 BAR.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Fire Fighting
Issued 15 April 1994 Resolved
PROPERLY EQUIP EACH FIRE STATION WITH FIRE HOSE, NOZZLE AND SPANNER WRENCH.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Fire Fighting
Issued 15 April 1994 Resolved
PROVIDE SERVICING REPORT FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Documentation
Issued 9 April 1994 Resolved
A VIOLATION OF 33 CFR 151.25 IN THAT A VESSEL GREATER THAT 400 GROSS TONS, FAILED TO MAINTAIN A OIL RECORD BOOK PART I, AS REQUIRED BY THIS SECTION.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Accommodation/Occupational Safety
Issued 9 April 1994 Resolved
VIOLATION OF 33 CFR 151.67 IN THAT THE VESSEL WAS DISCHARGING PLASTIC INTO THE OPEN OCEAN.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Documentation
Issued 9 April 1994 Resolved
A VIOLATION OF 33 CFR 155.720 IN THAT A VESSEL WITH A CAPACITY OF 250 OR MORE BARRELS OF OIL, FAILED TO HAVE TRANSFER PROCEDURES THAT MEET THE REQUIREMENTS OF 33 CFR 155.750.
Condition: Unknown
Due 19 April 1994
Resolved 19 April 1994
Accommodation/Occupational Safety
Issued 26 June 1988 Resolved
VESSEL WAS OPERATED INTO PT. COMFORT, TX EQUIPPED WITH INSTALLED TOILET FACILITIES WITH NO OPERABLE MARINE SANITATION DEVICE ON BOARD WHICH IS REQUIRED BY 33CFR159.7(C)((1). MASTER AQUIRED PORTABLE TOILETS FOR USE DURING THIS PORTCALL. AUTH CITE: 33USC1322(H)(4). PEN CITE: 33USC1322(J)
Condition: Unknown
Due 21 December 1992
Resolved 21 December 1992

Ownership record