Inspection history · 18
22 August 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8215654
3 December 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8042669
10 July 2024
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7955158
12 June 2024
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7933245
11 September 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7789487
2 December 2022
Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7603439
27 October 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7585130
18 October 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7579547
20 April 2021
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7179041
1 August 2020
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7188450
26 June 2020
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6987363
1 August 2019
COI Inspection · Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6769744
4 April 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6655787
7 November 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6576924
11 June 2018
In-Service Inspection · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6441577
7 November 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6302720
21 June 2016
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5908531
8 June 2016
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5899871
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 September 2025
Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Vessel is unable to actuate bilge pumps. To be repaired to the satisfaction of USCG Marine Inspector.
46 CFR 182.520(a)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 September 2025
Resolution: Verified vessel bilge system operated normally. Deficiency cleared.
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 10 September 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within.
Vessel is unable to test bilge high level alarms. To be repaired to the satisfaction of USCG Marine Inspector.
46 CFR 182.530(a)(2)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 September 2025
Resolution: Verified bilge high level alarm functioned properly. Deficiency cleared.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 September 2025
Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity: Navigation equipment and lights. Vessel did not have power in their upper deck operating station. To be repaired to the satisfaction of USCG Marine Inspector.
46 CFR 183.310(a)(1)(iv)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 September 2025
Resolution: Verified proper power to the upper deck operating station. Deficiency cleared.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 10 September 2025
Resolved
As appropriate for the intended voyage, a vessel must
carry adequate and up-to-date: Charts of large enough
scale to make safe navigation possible. Vessel's crew
was not able to verify up-to-date electronic charts.
46 CFR 184.420(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2025
Resolved 15 September 2025
Resolution: Verified vessel had up to date charts. Deficiency cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2025
Resolved
All electrical equipment and circuits must be clearly marked and identified. Vessel did not have their electrical panel at the operating station labeled.
46 CFR 183.220(d)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2025
Resolved 15 September 2025
Resolution: Verified proper labeling of electrical panel at operating station. Deficiency cleared.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 September 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel's burn gel was expired.
46 CFR 184.710
46 CFR 199.175(b)(10)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 24 September 2025
Resolved 22 September 2025
Resolution: Replaced expired burn gel
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 July 2024
Resolved
Each PFD must have at least 200 sq. cm. (31 sq. in.) of retroreflective material on its front side, at least 200 sq. cm. on its back side and at least 200 sq. cm. of mat. Retroreflective material on 19 PFDs were worn and no longer reflective. Vessel is limited to carry 15 adult passengers until the lifejackets are repaired or replaced. The authorization of carriage of children remains unchanged.
46 CFR 160.077-13(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2024
Resolved 30 August 2024
Resolution: Operator replaced retro.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 July 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication; Coast Guard Light List; Tide tables; and Current tables. Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Vessel did not have up to date charts on board.
46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2024
Resolved 30 August 2024
Resolution: [name withheld] provided an email with proof of updates complete to AIS.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2024
Resolved
A vessel must have one or more...vessel of more than 7.9 meters (26ft) in length, but not more than 19.8 meters (65 Feet), must carry a minimum of one life buoy of not less that 610 millimeters (24 inches) in diameter...resistant to deterioration from UV light... Life buoy was 22 inches in diameter, with a cotton life line, and the floating water light was not attached. Rectify to comply with regulation.
46 CFR 180.70
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2024
Resolved 30 August 2024
Resolution: Life buoy was replaced with an approved life buoy of appropriate size.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 10 July 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Breathalyzer was not calibrated within 6 to 12 months as directed in the manufacturer instructions. Rectify to the satisfaction of the attending Marine Inspector.
46 CFR 4.06-15(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2024
Resolved 30 August 2024
Resolution: Vessel operator purchased alcohol test trips that will be utilized in substitute to breathalyzer.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 October 2023
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. Marine Inspector found 15 life jackets with deteriorated retroreflective material. Vessel is reduced to 19 adult passengers until life jackets are repaired to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2023
Resolved 6 December 2023
Resolution: Affixed new retro
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 October 2023
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Marine Inspector found 01 ring life buoy without the vessel name. Ensure the vessel name is affixed to the ring life buoy to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 6 December 2023
Resolution: Affixed name on buoy
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 31 October 2023
Resolved
A vessel must comply with the applicable requirements for any radio including the requirements for a station license and installation certificates to be issued by the Federal Communication Commission, as set forth in 47 CFR part 80. Marine Inspector found 01 radio that not operational. Repair to the satisfaction of the attending
Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 6 December 2023
Resolution: Installed new radio
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 May 2021
Resolved
A vessel must carry one floating waterlight unless it is limited to daytime operation, in which case no floating light is required. Vessel's floating waterlight is inoperational. Prove proper operation of waterlight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 17 May 2021
Resolution: Vessel acquisitioned new battery for floating waterlight and proved proper operation with picture and video.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 May 2021
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the international and inland navigation rules. Vessel's masthead and anchor light is not installed. prove proper operation of masthead and anchor light. Vessel is restricted to daytime operation only.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 7 June 2021
Resolution: Combination masthead light and anchor light installed
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 26 June 2020
Resolved
Inspect all railings and their attachment to the hull structure. Mooring cleat starboard side amidships is loose and needs to be secured to the deck. Current condition allows water intrusion into mounting location through the fiberglass. Upper deck railing has two locations, port and starboard sides amidships, where the railing posts are loose at the deck mount. Current condition allows water intrusion into mounting location through the fiberglass. Both railing mounts need to be secured to the deck.
46 CFR 176.25-5(a)(4)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2020
Resolved 7 July 2020
Resolution: Mooring cleat starboard side amidships was secured to the deck. Upper deck railing locations, port and starboard sides amidships, were secured to the deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 November 2018
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Marine Inspector observed fuel leak coming from port side outboard engine. Vessel must rectify issue to the satisfaction of the attending marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2018
Resolved 10 December 2018
Resolution: Observed no leaking fuel. Vessel rep replaced cracked fuel bowl on one carburetor. All tests sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 November 2018
Resolved
At each initial inspection and subsequent inspection for certification, the marine inspector may require that an abandon ship, man overboard and fire drill be held under simulated emergency conditions specified by the inspector. Vessel was not able to get underway to conduct man overboard and fire drill. Vessel shall not operate until drills are conducted to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2018
Resolved 10 December 2018
Resolution: Conducted drills, all sat.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 13 November 2017
Resolved
Vessel rep reported port engine inoperable. At each inspection, the marine inspector may require a man overboard drill to be conducted. Vessel rep shall provide operable engine prior to carrying passengers. 46 CFR 176.808(g)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2017
Resolved 14 November 2017
Resolution: The vessel rep also reported that the trouble with the engine was in the relays and provided a satisfactory test of the port engine. Steering tests, engine shutdowns, and drills were all conducted satisfactory.
Engineering › Bilge Water Management System › Pump
Issued 13 November 2017
Resolved
Automatic bilge pump not permanently mounted to the vessel. The pump shall be permanently mounted to the vessel. Prior to carrying passengers. 46 CFR 182.520(e)(3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 November 2017
Resolved 14 November 2017
Resolution: The vessel rep had screwed the automatic bilge pumps to plates and the plates were permanently bonded to the hull via a marine grade adhesive.
Fire Fighting › Fire Bucket › Capacity
Issued 13 November 2017
Resolved
Vessels not required to have power driven fire pumps must have 3, 9.5L (2.5 Gallon) fire buckets marked "Fire Bucket" in a contrasting color. Vessel has 2 gallon fire buckets. Replace 2 gallon buckets with 2.5 gallon buckets. 46 CFR 181.610
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 14 November 2017
Resolution: The vessel rep provided three 2.5 gallon fire buckets to replace the three 2 gallon buckets.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 November 2017
Resolved
Vessel has not undergone an annual inspection since 23JUN16. Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel shall undergo and complete an annual inspection prior to carrying passengers. 46 CFR 176.500(b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2017
Resolution: Vessel completed a satisfactory Annual Inspection.