This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
1038 - Regulatory (Subpart C or D), Net Ton
1038 - Regulatory (Subpart C or D), Gross Ton
Maury page id
psix-40876
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
VESSEL MAY NOT LOAD OR DISCHARGE ANY CARGOES UNTIL PROPER AND PERMANENT REPAIRS ARE MADE TO #1 CARGO TANK WHERE AN APPROX. 1/2" HOLE HAS APPEARED IN A WELD SEAM. GAUGINGS SHALL BE TAKEN OF THE SURROUNDING AREA TO ENSURE PROPER METAL THICKNESS STILL EXISTS. LEGACY COMPONENT DESC: Bulkhead
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 May 2002
Resolved 21 June 2002
Resolution: Corrected. See narrative.
Electrical › Electrical Distribution System (service) › Cable
Issued 23 January 2002Resolved
Install cable supports on all cargo pump power distribution cables IAW 46 CFR 111.60-5
Condition: Unknown
Due 23 January 2002
Resolved 23 January 2002
Resolution: Clips and supportst installed IAW IEEE Standard 45, Sec 20..
Construction/Loadline › Hull
Issued 23 January 2002Resolved
Reapir 1/8"X1' fracture IWO headlog corner plate, port side IAW NVIC 7-68 and CCGD EIGHT Barge Repair Guide. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Due 23 January 2002
Resolved 23 January 2002
Resolution: Fracture repaired IAW above referenced guides and air tested sat.
Deck/Cargo
Issued 5 May 1995Resolved
All flame screens are to be replaced prior to the transfer of cargo.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Deck/Cargo
Issued 5 May 1995Resolved
All cargo piping is to be hydrotested prior to using for the transfer of cargo.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Deck/Cargo
Issued 5 May 1995Resolved
A U.S. Coast Guard Cargo Tank Internal inspection is required prior to the transfer of cargo.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995