Inspection history · 37
7 May 2004
Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2062091
31 March 2003
Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1765699
2 October 2001
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1469713
18 May 2000
Deficiency Check · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1397430
14 February 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1427777
10 January 2000
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 815855
21 July 1999
Re-Inspection · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1399153
25 February 1999
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1426173
11 June 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2882
22 May 1998
COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1472218
9 December 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 185728
29 August 1997
Damage Survey
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1439909
26 August 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 722679
21 August 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 54460
23 April 1997
Deficiency Check · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1447701
24 March 1997
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1093135
16 May 1996
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1082578
19 April 1995
Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1374262
4 March 1994
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1165166
22 February 1994
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1164332
2 April 1993
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1412498
6 May 1992
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1259066
7 April 1992
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1259282
27 September 1991
Examination of Repairs
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 935601
29 March 1991
Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1243369
24 July 1990
Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 918916
25 June 1990
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1212779
7 May 1989
Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1193814
22 January 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1204011
17 August 1988
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1038388
19 July 1988
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1032903
26 June 1987
COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1004410
22 July 1986
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 993803
4 September 1985
Deficiency Check
Physical examination · THE UNKNOWN UNIT · Activity 991791
2 August 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 982324
25 July 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1287623
21 June 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1291541
Electrical
Issued 2 October 2001
Resolved
PROVIDE TOP FOR GENERATOR BATTERY BOX.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Construction/Loadline
Issued 2 October 2001
Resolved
REPLACE #3 PORT VOID AND #4 STBD VOID GASKETS.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Construction/Loadline
Issued 2 October 2001
Resolved
REPLACE/REPAIR HATCH COAMING FOR #5 PORT VOID.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Deck/Cargo
Issued 2 October 2001
Resolved
REPAIR OR REPLACE THERMAL FLUILD HEATER ALARM.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Lifesaving
Issued 18 May 2000
Resolved
CLEAN ALL OIL FROM STBD CARGO PUMP ENGINE DRIP PAN.
Condition: Unknown
Due 19 May 2000
Resolved 24 May 2000
Lifesaving
Issued 18 May 2000
Resolved
CLAEN ALL OIL AND RAGS FROM OIL HEATER ROOM. HEATER IS NOT TO OPERATE UNTILCLEANED.
Condition: Unknown
Due 19 May 2000
Resolved 24 May 2000
Engineering
Issued 18 May 2000
Resolved
PROVIDE TESTS OF THERMIAL OIL HEATER ALARMS AND SAFETY DEVICES.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Construction/Loadline
Issued 10 January 2000
Resolved
Make permanent repairs at scheduled ISE in place of temp repairs to stbd plating due to 8" vertical fracture located stbd wing void.
Condition: Unknown
Due 14 February 2000
Resolved 16 February 2000
Deck/Cargo
Issued 21 July 1999
Resolved
PROVIDE CHECK LIST FOR SAFETY CHECKS AND PROVIDE SAFETY TESTS OF INSTALLED THERMAL FLUID HEATER.
Condition: Unknown
Due 21 August 1999
Resolved 27 July 1999
Deck/Cargo
Issued 25 February 1999
Resolved
DUE TO EXESSIVE WASTAGE REPLACED 22'X 04' SECTION OF TH STBD CARGO TANK BOTTOM CENTERED 18' FORWARD OF THE SUMP WELL.
Condition: Unknown
Due 25 February 1999
Resolved 1 March 1999
Deck/Cargo
Issued 25 February 1999
Resolved
DUE TO WASTAGE REPLACED 15'X 4' SECTION OF THE PORT CARGO TANK BOTTOM CENTERED 14'FORWARD OF THE SUMP WELL AND A 11'X 4 SECTION OF PORT CARGO TANK BOTTOM CENTERED 5' AFT FROM THE FRONT OF THE TANK.
Condition: Unknown
Due 25 February 1999
Resolved 1 March 1999
Deck/Cargo
Issued 22 May 1998
Resolved
MAKE AVAILABLE FOR INSPECTION ALL CARGO TANK EXPANSION TRUNK TOPS AT NEXT CARGO TANK INTERNAL EXAM, BUT NOT LATER THAN 30APR99.
Condition: Unknown
Due 22 May 1998
Resolved 22 May 1998
Construction/Loadline
Issued 29 August 1997
Resolved
REPAIR/REPLACE DAMAGE TO #3 FRAME (FROM AFT) LOCATED IN NO.2 STBD VOID.
Condition: Unknown
Due 31 August 1997
Resolved 2 September 1997
Construction/Loadline
Issued 29 August 1997
Resolved
REPAIR/REPLACE INSERT LOCATED PORT SIDE, FWD RAKE, IN WAY OF SHEER AT TURN OF MAIN DECK IAW NVIC 7-68 (RADIUS CORNERS) NO LATER THAN 30 APRIL 1998.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Construction/Loadline
Issued 29 August 1997
Resolved
REPAIR/REPLACE DAMAGE TO #2 SIDE LONG LOCATED IN NO. 2 PORT VOID.
Condition: Unknown
Due 31 August 1997
Resolved 2 September 1997
Construction/Loadline
Issued 29 August 1997
Resolved
REPAIR/REPLACE #1 BOTTOM LONG/#2 SIDE LONG IN WAY OF NO.4 PORT VOID.
Condition: Unknown
Due 31 August 1997
Resolved 2 September 1997
Construction/Loadline
Issued 29 August 1997
Resolved
REPAIR/REPLACE #2 WEB FRAME & #2 BOTTOM LONG, WHERE DAMAGED, IN WAY OF PORTRAKE.
Condition: Unknown
Due 31 August 1997
Resolved 2 September 1997
Construction/Loadline
Issued 29 August 1997
Resolved
CROP AND RENEW PORT SIDE RAKE, IN WAY OF PUSH KNEE, WHERE DAMAGED.
Condition: Unknown
Due 31 August 1997
Resolved 2 September 1997
Construction/Loadline
Issued 29 August 1997
Resolved
REPAIR/REPLACE DAMAGE TO #3/4 WEB FRAMES/# 2 SIDE LONG, LOCATED IN NO.1 STBD VOID.
Condition: Unknown
Due 31 August 1997
Resolved 2 September 1997
Construction/Loadline
Issued 29 August 1997
Resolved
REPAIR/REPLACE DAMAGE TO #1/2 SIDE LONGS LOCATED IN NO.3 STBD VOID.
Condition: Unknown
Due 31 August 1997
Resolved 2 September 1997
Construction/Loadline
Issued 16 May 1996
Resolved
DRILL STOP, VEE AND WELD TWO CRACKS IN THE DECK PLATE IWO THE FORWARD, STBD. MOORING CLEAT.
Condition: Unknown
Due 22 May 1996
Resolved 23 May 1996
Accommodation/Occupational Safety
Issued 16 May 1996
Resolved
REPAIR WASTED STEPS ON THE WALK-OVER RAMP, MID-SHIPS.
Condition: Unknown
Due 22 May 1996
Resolved 23 May 1996
Deck/Cargo
Issued 16 May 1996
Resolved
REMOVE/REPLACE WASTED CARGO PUMP START AIR RECIEVER.
Condition: Unknown
Due 22 May 1996
Resolved 23 May 1996
Deck/Cargo
Issued 16 May 1996
Resolved
REPAIR LEAKING SEAL ON THE INBOARD THERMAL FLUID HEATER CIRCULATION PUMP.
Condition: Unknown
Due 22 May 1996
Resolved 23 May 1996
Construction/Loadline
Issued 16 May 1996
Resolved
EVALUATE AND REPAIR AS NECESSARY TWO SET-INS IN THE SHEER STRAKE, PORT SIDEIWO THE DISCHARGE MANIFOLD.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Construction/Loadline
Issued 16 May 1996
Resolved
VEE AND WELD CRACK IN THE FORWARD, STARBOARD MOORING CLEAT.
Condition: Unknown
Due 22 May 1996
Resolved 23 May 1996
Engineering
Issued 22 February 1994
Resolved
PROVIDE A RELIEF VALVE FOR AIR RCVR SET AT NO MORE THAN THE MAWP OF THE TANK.
Condition: Unknown
Due 22 February 1994
Resolved 22 February 1994
Electrical
Issued 22 February 1994
Resolved
RENEW FUEL RETURN HOSE ON GENERATOR WITH COAST GUARD APPROVED HOSE AND FITTINGS.
Condition: Unknown
Due 22 February 1994
Resolved 22 February 1994
Electrical
Issued 7 April 1992
Resolved
ELECTRICAL CONTROL BOXES FOR THERMAL FLUID HEATER TO BE EXAMINED FOR THE FOLLOWING: BAD INSULATION ON WIRES, EXCESS WIRING, IMPROPER USE OF WIRE NUTS, LOOSE CIRCUIT BOARDS, BAD WIRE CONNECTORS, ETC.
Condition: Unknown
Due 7 April 1992
Resolved 7 April 1992
Deck/Cargo
Issued 25 June 1990
Resolved
REPLACE PVC PIPING IN THE THERMAL FLUID REPLENISHMENT SYSTEM WITH METALLIC MATERIAL.
Condition: Unknown
Due 25 June 1990
Resolved 25 June 1990
Engineering
Issued 25 June 1990
Resolved
MAKE PROPER REPAIRS TO INTERNAL WELDS ON ATTACHMENTS, WASTED GASKET SURFACEON HAND HOLE COVER AND PROVIDE DATA PLATE FOR UNIT OR REMOVE FROM THE VESSEL.
Condition: Unknown
Due 25 June 1990
Resolved 25 June 1990
Construction/Loadline
Issued 19 July 1988
Resolved
WELD TEAR FRACTURE IN DECK JUST AFT OF HEAD LOG. WELD INSIDE AND OUT.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Deck/Cargo
Issued 21 June 1985
Resolved
CONDUCT OPERATIONAL TEST OF CARGO PIPING DURING NEXT OFFLOADING OF CARGO. THIS TEST TO BE CONDUCTED NO LATER THAN 21 SEPT 1985.
Condition: Unknown
Due 21 June 1985
Resolved 21 June 1985