TRINCOS is a 1965 tank barge. The Coast Guard has recorded 11 inspections since 1984, most recently in March 1994, along with 4 deficiencies.
Records from 1984 to 1994. Most recent: inspection, 21 March 1994.
- Built
- 1965
- Last inspected
- 21 March 1994
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded1
Years with a record
10 calendar years (1984–1994)
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it12 - Regulatory (Subpart C or D), Net Ton
12 - Regulatory (Subpart C or D), Gross Ton
12 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
21 March 1994
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1466343
7 July 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1152053
22 March 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 841267
23 March 1992
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1259793
25 March 1991
Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1305640
26 March 1990
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 913737
27 March 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1195681
27 January 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1324100
16 April 1987
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1003867
27 January 1986
Credit Drydock · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1296490
7 November 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1286874
Deficiency record · 4
Documentation
Issued 22 March 1993
Resolved
SUBMIT A VESSEL RESPONSE PLAN IN ACCORDANCE WITH 33 CFR 155.1065 TO COMMANDANT (G-MEP-6) FOR APPROVAL AND PROVIDE EVIDENCE THAT THIS HAS BEEN DONE PRIOR TO THE NEXT TRANSFER OPERATION.
Documentation
Issued 22 March 1993
Resolved
PROVIDE A WRITTEN PROGRAM FOR PROTECTION FROM BENZENE THAT MEETS THE REQUIREMENTS IN 46 CFR 197, OR PROVIDE LABORATORY ANALYSIS RESULTS FOR CARGOES WHICH SHOW LESS THAN 0.5% BENZENE BY VOLUME.
Deck/Cargo
Issued 22 March 1993
Resolved
REMOVE 3/4 INCH GOOSE NECK VENT ON THE PORT AND STARBOARD CARGO TANKS. _x001C_ VENT PIPE MUST BE CAPPED OFF TO PREVENT VENTING OF PRODUCT. _x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 22 March 1993
Resolved
REMOVE 3/4 INCH VENT PIPE INSTALLED TO THE PORT & STARBOARD MIXING TANKS._x001C_ PROVIDE A MINIMUM 2-1/2 INCH VENT PIPE WITH A PRESSURE-VACUUM VALVE FOR _x001C_ THE MIXING TANKS. _x001C_ _x001C_