MAURY USCG vessel records Sign in
← All vessels

ARGOSY IV

ARGOSY IV is a 1994 passenger vessel (inspected). The Coast Guard has recorded 62 inspections since 1994, most recently in July 2018, along with 181 deficiencies.

Records from 1994 to 2018. Most recent: inspection, 24 July 2018.

Built
1994
Last inspected
24 July 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC3523
408957
Flag
INDIA
367009540 (licence lapsed)
Maury page id
psix-408957

Inspections, by type

…with no type recorded12
Years with a record 11 calendar years (1994–2018)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it1688 - Convention (Subpart B), Net Ton
1141 - Regulatory (Subpart C or D), Net Ton
5497 - Convention (Subpart B), Gross Ton
1477 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC3523MMSI 367009540 · expired · compulsorily equipped · granted 8 January 2005, cancelled 14 March 2015
WCP6234MMSI not assigned · expired · compulsorily equipped · granted 11 January 1995, cancelled 19 March 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 62

24 July 2018 Uninspected Other
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6492467
24 August 2006 Security Plan Amendment Review - ASP
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2758597
24 February 2005 Uninspected Other · In-Service Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2292838
24 January 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2280063
30 July 2004 Initial Certification
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2150425
30 July 2004 Deadweight Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2150704
5 May 2004 Underwater Inspection in lieu of Drydock
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2060082
6 August 2003 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1842193
3 October 2002 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1683772
9 December 1998 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 807292
6 August 1998 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1459448
12 June 1998 Deadweight Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1461053
7 May 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1471823
18 March 1998 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1124494
19 February 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1433313
10 January 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 124257
16 December 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1116711
17 November 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1383735
4 September 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1110886
6 August 1997 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1386070
25 June 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1113775
27 May 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1368270
14 May 1997 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1105154
1 April 1997 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1100850
22 March 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 21636
19 March 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1098344
19 February 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1460066
16 January 1997 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1099584
19 December 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1094354
19 November 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1434484
17 October 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1442474
7 October 1996 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 839436
6 September 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 948452
8 August 1996 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1424275
22 July 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1085676
14 July 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 171562
20 June 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1407728
17 April 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 103588
3 April 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1079025
31 March 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 133706
20 March 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1385664
19 January 1996 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1385626
11 December 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 874532
20 November 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1434325
10 August 1995 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1438344
16 June 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 878348
26 May 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1181144
13 April 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 25388
22 March 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 826395
17 February 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 152898
9 February 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 843003
3 January 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 853285
15 December 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 851781
26 November 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 37722
9 November 1994 Re-Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 866874
24 October 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 870971
20 September 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 870847
11 August 1994 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1177132
11 August 1994 Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1429916
26 July 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1179553
15 July 1994 Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1174373
26 June 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 862893

Deficiency record · 181

Engineering
Issued 6 August 1998 Resolved
Repair fuel oil leak in way of port main diesel engine racor fuel filter outlet piping.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Fire Fighting
Issued 6 August 1998 Resolved
Properly repair main deck "roxblocks" deck penetation in way of engineroom,aft of cooling water pumps.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Fire Fighting
Issued 6 August 1998 Resolved
Repair aft engineroom bulkhead penetration, aft of port main diesel engine,as per A-0 Structural Fire Protection regulations.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Electrical
Issued 6 August 1998 Resolved
Install outlet cover on 120vac outlet in hardcount room forward bulkhead.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Electrical
Issued 6 August 1998 Resolved
Repair as necessary all motor and equipment stuffing tubes and wire clamps.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Deck/Cargo
Issued 6 August 1998 Resolved
Prove proper operation of bowthruster unit.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Fire Fighting
Issued 6 August 1998 Resolved
Ensure smoke detector in liquor space registers in the wheelhouse and is inproper working order.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Lifesaving
Issued 6 August 1998 Resolved
Ensure all lifering stowage stations are marked in accordance with 46CFR subchapter W.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Engineering
Issued 6 August 1998 Resolved
Prove proper operation of port steering station gauges.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Fire Fighting
Issued 6 August 1998 Resolved
Adjust for proper operation of fire screen doors 12, 16, and 24.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Electrical
Issued 6 August 1998 Resolved
Properly wire freeze protection cables in way of sewage and potable water hoses.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Electrical
Issued 6 August 1998 Resolved
Prove proper operation of battery operated "E" light in way of hold deck locker room on port side.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Electrical
Issued 6 August 1998 Resolved
Prove proper operation of "E" light in way of 2nd deck fwd on stbd side.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Engineering
Issued 6 August 1998 Resolved
Properly adjust all main engine & ships service generator exhaust system hanger brackets.
Condition: Unknown
Due 6 September 1998
Resolved 3 October 2002
Resolution: cleared for administrative reasons
Electrical
Issued 19 February 1998 Resolved
Replace plastic wire ties with metal wire ties on wire in overhead in hard count.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Electrical
Issued 19 February 1998 Resolved
Make permanent installation of E-light wiring in hard count room and vault.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Electrical
Issued 19 February 1998 Resolved
Indentify breakers and properly mark all circuit directory cards in breakerpanels throughout vessel.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Electrical
Issued 19 February 1998 Resolved
Provide up to date directory card in electric box L112 casino exhaust fans.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Documentation
Issued 19 February 1998 Resolved
Properly update fire plan to show new cashiers cage on the 3rd deck.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Fire Fighting
Issued 19 February 1998 Resolved
Properly install safety box for CO2 firefighting system pull station located at vessel's liquor locker entrance.
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Construction/Loadline
Issued 17 November 1997 Resolved
PROVE PROPER OPERATION OF ALL SOUNDING TUBE VALVES (PARTIALLY FROZEN).
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Fire Fighting
Issued 17 November 1997 Resolved
ENSURE PROPER GAP ON FIRE DAMPERS IWO MAIN DECK INTERIOR
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Fire Fighting
Issued 17 November 1997 Resolved
CLEAN ALL VENT GRILLS IWO FIRE DAMPERS.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Electrical
Issued 17 November 1997 Resolved
PROVE ADEQUACY OF SURGE SUPPRESSOR IWO SURVEILLANCE SPACE, O/B BKHD.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Lifesaving
Issued 17 November 1997 Resolved
PROVE ADEQUACY OF MAN OVERBOARD RETRIEVAL PLAN
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Accommodation/Occupational Safety
Issued 17 November 1997 Resolved
ENSURE CLEANLINESS OF ALL SERVICE BARS
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Fire Fighting
Issued 17 November 1997 Resolved
PROVE PROPER CLEARANCE ON ALL DOUBLE HUNG FSDs
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Electrical
Issued 17 November 1997 Resolved
REMOVE EXTENSION CORD FROM HARD COUNT IWO TELEPHONE BELL.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Electrical
Issued 17 November 1997 Resolved
PROVE PROPER OPERATION OF "E" LIGHTS IN CARD CUT ROOM AND LIQUOR SPACE.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Electrical
Issued 17 November 1997 Resolved
PROPERLY LABEL BREAKERS IWO "CARD STORAGE AREA" DISTRIBUTION PANEL.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Lifesaving
Issued 17 November 1997 Resolved
PROVE ADEQUACY (NON-COMUSTIBILITY) OF TRASH CANS IN ALL RESTROOMS.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Construction/Loadline
Issued 17 November 1997 Resolved
REPAIR HYDRAULIC SYSTEM ON WTD#3 IAW MANUFACTURERS INSTRUCTIONS
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Electrical
Issued 17 November 1997 Resolved
ENSURE PROPER INSTALLATION OF WIRING IWO 2ND DECK WOMENS RESTROOM STORAGE OVERHEAD AND TELEPHONE ROOM OVERHEAD.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Fire Fighting
Issued 17 November 1997 Resolved
PROVE PROPER OPERATION OF BOWTHRUSTER FIRE DAMPER RESET HANDLE.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Lifesaving
Issued 17 November 1997 Resolved
PROVIDE MSDS SHEETS FOR ALL CLEANING GEAR IN LOCATIONS WHEREVER STORED.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Electrical
Issued 6 August 1997 Resolved
Repair junction box on coin conveyor motor in hard count._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Electrical
Issued 6 August 1997 Resolved
PROVE PROPER OPERATION OF "E" LIGHT IN MAIN DECK LADIES RESTROOM.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Construction/Loadline
Issued 6 August 1997 Resolved
MAKE ACCESSIBLE FOR INSPECTION, ALL STERN VOID COMPARTMENTS._x001C_ (HATCHES ARE RUSTED SHUT)
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Electrical
Issued 6 August 1997 Resolved
PROVE PROPER OPERATION OF #3 SSG REVERSE POWER RELAY.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Fire Fighting
Issued 6 August 1997 Resolved
REMOVE ALL PLEXIGLASS AND COMBUSTIBLE TRASH RECEPTICLES FROM INTERIOR SPACES.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Fire Fighting
Issued 6 August 1997 Resolved
REPAIR HOLES IN AFTER BULKHEAD, MAIN DECK STERN, TO MEET REQUIREMENTS OF A CLASS "A" BULKHEAD.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Electrical
Issued 6 August 1997 Resolved
PROVE PROPER OPERATION OF "E" LIGHT IWO 2nd DECK, PORT SIDE, AFT.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Electrical
Issued 6 August 1997 Resolved
REMOVE TEMPORARY OUTLET STRIPS IN VAULT.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Electrical
Issued 6 August 1997 Resolved
INSTALL COVERS ON OUTLETS LOCATED ON AFT BULKHEAD IN VAULT SPACE.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Fire Fighting
Issued 6 August 1997 Resolved
INSTALL A PROPERLY SERVICED PORTABLE FIRE EXTINGUISHER IN LIQUOR SPACE.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Electrical
Issued 27 May 1997 Resolved
Ensure emergency public address systm space is restricted to licensed marine officers.
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Electrical
Issued 27 May 1997 Resolved
Prove proper operation of and ensure emergency is unable to be silenced.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 27 May 1997 Resolved
Remove electric extension cord from 1st deck cashiers cage.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Lifesaving
Issued 27 May 1997 Resolved
Prove proper operation of all engineroom general alarms.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Construction/Loadline
Issued 27 May 1997 Resolved
Ensure cable penetration in cage manager's office, port bulkhead, is sealedw/ approved fire stop.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 27 May 1997 Resolved
Provide proper cover for aft capstan control box._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Lifesaving
Issued 27 May 1997 Resolved
Properly store all flammable liquids in slot repair office.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Lifesaving
Issued 27 May 1997 Resolved
Prove proper operation of oxygen sensor in generator space.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Unknown
Issued 27 May 1997 Resolved
Eliminate chill water leak IWO inboard chill water pump.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Construction/Loadline
Issued 27 May 1997 Resolved
Adjust #1 wtd for proper operation.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Navigation
Issued 27 May 1997 Resolved
Prove proper operation of EDG space sound powered phone.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Electrical
Issued 27 May 1997 Resolved
Remove all or repair to orginal all fiber optic lighting on exterior bulkheads. (weather)
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Construction/Loadline
Issued 27 May 1997 Resolved
Make bulkhead watertight at frame 35 in crew locker space.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Fire Fighting
Issued 19 February 1997 Resolved
Prove proper installation of beer and liquor lines supplying main deck fwd bar.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Electrical
Issued 19 February 1997 Resolved
Prove proper operation of emergency temporary power lighting (12VDC) on each deck.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Fire Fighting
Issued 19 February 1997 Resolved
Adjust for proper operation FSD #25
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Fire Fighting
Issued 19 February 1997 Resolved
PROVIDE COPIES OF FIRE LOAD DETERMINATION FOR SURVEILLANCE SPACE.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Fire Fighting
Issued 19 February 1997 Resolved
Prove proper operation of second deck fire dampers #21, 23, 24, and 31_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Fire Fighting
Issued 19 February 1997 Resolved
Make available for inspection all exhaust side fire dampers, second deck.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Accommodation/Occupational Safety
Issued 19 February 1997 Resolved
Ensure cleanliness of second and third deck bars.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Accommodation/Occupational Safety
Issued 19 February 1997 Resolved
REMOVE ALL CLEANING GEAR FM SURVEILLANCE SPACE.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Electrical
Issued 19 February 1997 Resolved
PROPERLY INSTALL WIRING ABOVE ENTRANCE TO SERVICE ELEVATOR HYDRAULIC SPACE.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Electrical
Issued 19 February 1997 Resolved
REMOVE ALL MODIFIED/TEMPORARY SURGE SUPPRESSORS FROM ALL OFFICE SPACES.
Condition: Unknown
Due 19 February 1997
Resolved 19 February 1997
Fire Fighting
Issued 19 November 1996 Resolved
PROVIDE INSTRUCTIONS TO OPERATE FIRE DAMPERS, BOW THRUSTER SPACE.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Electrical
Issued 19 November 1996 Resolved
PROPERLY FILL OUT DIRECTORY CARDS IN P404, P403 TO VERIFIED AT NEXT INSPECTION.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Electrical
Issued 19 November 1996 Resolved
PROVIDE SUITABLE GLOBE FOR LIGHT IN BEER COOLER (LOWER HOLD).
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Engineering
Issued 19 November 1996 Resolved
REPAIR COOLING WATER PIPE BRACKET IWO PORT SSG HEAT EXCHANGER.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Lifesaving
Issued 19 November 1996 Resolved
RENEW GRABLINES AND WEBBING ON LIFERINGS, STBD BRIDGE WING, PORT QUARTER 4TH DECK, MAINDECK PORT AND STBD BOW.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Fire Fighting
Issued 19 November 1996 Resolved
LABEL FIRE EXTINGUISHER CABINET 2ND DECK SERVICE BAR-"DO NOT BLOCK".
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Fire Fighting
Issued 19 November 1996 Resolved
PLACE SPANNER IN FIRE STATION #21.
Condition: Unknown
Due 25 November 1996
Resolved 25 November 1996
Fire Fighting
Issued 19 November 1996 Resolved
PROVE PROPER OPERATION OF FSD #2.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Electrical
Issued 19 November 1996 Resolved
REMOVE EXTENSION CORDS AND OUTLET MULTIPLIERS FROM ALL CASINO CAGES AND BARS.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Engineering
Issued 19 November 1996 Resolved
REMOVE ALL FLEXIBLE HOSE IWO MDE'S AND SSG'S IN EXCESS OF 30", (OIL, FUEL AND HYDRAULIC SYSTEMS) AND REPLACE W/STEEL TUBING.
Condition: Unknown
Due 19 November 1996
Resolved 19 November 1996
Lifesaving
Issued 8 August 1996 Resolved
ENSURE PROPER MARKING OF GENERAL ALARM BELL FORWARD OF 2ND DECK TICKETING SPACE.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Electrical
Issued 8 August 1996 Resolved
REMOVE PORTABLE SURGE PROTECTORS AND REPLACE W/PERMANANT FIXTURES IN SLOT REPAIR, SLOT TRACKING, AND THE FIRST AID SPACE.
Condition: Unknown
Due 8 August 1996
Resolved 8 August 1996
Electrical
Issued 8 August 1996 Resolved
PROVE PROPER OPERATION OF "E" LIGHT IWO MAIN DECK, STBD SIDE.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Lifesaving
Issued 8 August 1996 Resolved
LABEL GENERAL ALARM BELL IWO PORT, CENTER AND STBD SHAFT SPACES.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Engineering
Issued 8 August 1996 Resolved
PROVE PROPER OPERATION OF #1 SSG OVERSPEED TRIP.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Engineering
Issued 8 August 1996 Resolved
REPAIR OIL LEAK IWO CENTER Z-DRIVE, POTENTIOMETER HOUSING.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Fire Fighting
Issued 8 August 1996 Resolved
PROVE PROPER OPERATION OF BILGE SUCTION MANIFOLD.
Condition: Unknown
Due 9 August 1996
Resolved 9 September 1996
Electrical
Issued 8 August 1996 Resolved
INSTALL RUBBER MAT IWO SHORE TIE BUS PANEL.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Electrical
Issued 8 August 1996 Resolved
INSTALL CLOBE ON OUTSIDE LIGHT FIXTURE IWO BOWTHRUSTER SPACE.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Electrical
Issued 8 August 1996 Resolved
REPLACE SWITCH PLATE AND PROPERLY MOUNT ACCU STAT IWO EOS AIR HANDLER.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Lifesaving
Issued 8 August 1996 Resolved
REPLACE LIFERING PORT SIDE MAIN DECK AFT.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Electrical
Issued 8 August 1996 Resolved
INSTALL BREAKER BLANK IWO LIGHT PANELS #L101.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Accommodation/Occupational Safety
Issued 8 August 1996 Resolved
CLEAN RECESSED AREA IN ALL BARS BACK IN THE CORNERS.
Condition: Unknown
Due 8 August 1996
Resolved 8 August 1996
Fire Fighting
Issued 8 August 1996 Resolved
UPDATE FIRE CONTROL PLAN.
Condition: Unknown
Due 8 August 1996
Resolved 8 August 1996
Fire Fighting
Issued 8 August 1996 Resolved
PROVIDE PROPER INSTRUCTIONS FOR FIXED CO2 SYSTEM FOR LOCAL OPERATION INCLUDING OPERATION OF MANUEL DAMPER IWO MAIN BANK.
Condition: Unknown
Due 8 August 1996
Resolved 8 August 1996
Engineering
Issued 8 August 1996 Resolved
PROVE PROPER OPERATION OF ALL MDE AND SSG EXHAUST HANGERS AND BRACKETS.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Fire Fighting
Issued 8 August 1996 Resolved
PROVE PROPER OPERATION OF FIRE DAMPERS IN WAY OF ELEVATOR SHAFTS.
Condition: Unknown
Due 8 August 1996
Resolved 8 August 1996
Engineering
Issued 8 August 1996 Resolved
UPDATE OIL TRANSFER PROCEDURE UPDATE PHONE LIST, PERSON-IN-CHARGE, AND SPILL SHUTDOWN PROCEDURE.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Electrical
Issued 8 August 1996 Resolved
PROPERLY INSTALL ELECTRICAL WIRING TO FIBER OPTIC LINES 3RD DECK BREEZEWAY PORT AND STBD.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Fire Fighting
Issued 8 August 1996 Resolved
PROVE PROPER OPERATION OF FIRE DAMPERS IN THE SUPPLY VENT DUCTS.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Fire Fighting
Issued 8 August 1996 Resolved
PROVE PROPER OPERATION OF EXHAUST AUTO DAMPERS MAIN DECK AFT PORT SIDE AND FD NO3.
Condition: Unknown
Due 9 August 1996
Resolved 9 September 1996
Accommodation/Occupational Safety
Issued 8 August 1996 Resolved
CLEAN ALL VENTILATION DUCTS BOTH SUPPLY AND EXHAUST.
Condition: Unknown
Due 8 August 1996
Resolved 8 August 1996
Fire Fighting
Issued 8 August 1996 Resolved
PROPERLY MARK MANUAL FIRE DAMPERS IN GUEST SERVICES SPACE, PORT STAIR TO LOWER HOLD AND TO GENERATOR ROOM EXHAUST IN MAIN DECK BANK.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Fire Fighting
Issued 8 August 1996 Resolved
ENSURE GENERATOR ROOM EXHAUST FIRE DAMPER PROPERLY ADJUSTED.
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Electrical
Issued 8 August 1996 Resolved
REMOVE TEMPORARY SURGE PROTECTOR AND REPLACE WITH PERMANENT INSTALLATION (EDG).
Condition: Unknown
Due 22 August 1996
Resolved 9 September 1996
Fire Fighting
Issued 20 June 1996 Resolved
Ensure fire safety plan reflects actual placement of equipment (fire axes).
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 20 June 1996 Resolved
Repair/ensure proper operation of FSD 2,3 and 4.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Remove all loose gear behind tv/electrical bank in surviellance space.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Repair junction box wiring, IWO stbd rescue boat winch controller (bottom).
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Clean all 12 volt dc battery terminals IWO E/R and SSG space and texas deck.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Construction/Loadline
Issued 20 June 1996 Resolved
ensure mats over lower level edges, hatches are not obscured.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
prove proper operation of exits signs, iwo 3rd deck, aft. casino.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Construction/Loadline
Issued 20 June 1996 Resolved
bolt down tread plates in all interior stair towers.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 20 June 1996 Resolved
Ensure fire dampers in change room are not blocked.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Properly secure electrical duct on fantail.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Properly secure electrical cable over entrance to port elevator hydraulic space.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Engineering
Issued 20 June 1996 Resolved
prove proper operation of mde shut downs from bridge
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 20 June 1996 Resolved
provide adequate fire detection and suppression for flammable liquid stores(liquor space)
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Fire Fighting
Issued 20 June 1996 Resolved
prove proper operation of sprinkler pump prior to 5july 96 #2 f/p will be cross connected to sprinkler piping until sprinkler pump repaired.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
properly label circuit directory card in panel l-103 (er)
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Engineering
Issued 20 June 1996 Resolved
repair stbd mde cooling water inlet to heat exchanger,leak in pipe.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
repair or replace water light on forward ring buoy.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Prove proper operation of "E" light IWO fwd break area stbd side.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 20 June 1996 Resolved
provide proper f/f training to non-marine crew
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996
Electrical
Issued 20 June 1996 Resolved
Prove proper operation of port fwd spotlight.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Construction/Loadline
Issued 20 June 1996 Resolved
make watertight, cable run in e/r bulkhead, above steering pump center.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Electrical
Issued 20 June 1996 Resolved
Properly mark all electrical "E" lights.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996
Fire Fighting
Issued 20 March 1996 Resolved
REPAIR MANUAL FIRE DAMPER IWO FSD#4 MAIN DK (HARD COUNT VENT) AND PROVE PROPER OPERATION.
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Navigation
Issued 20 March 1996 Resolved
PROVE PROPER OPERATION OF AFT BOW THRUSTER.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Construction/Loadline
Issued 20 March 1996 Resolved
PROVE PROPER OPERATION OF FRAME 47-59 BILGE LEVEL ALARM.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Electrical
Issued 20 March 1996 Resolved
REPLACE MISSING TELEPHONE ELECTRICAL BOX COVER IWO 2ND DK LADIES ROOM.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Fire Fighting
Issued 20 March 1996 Resolved
PROPERLY LABEL ALL FIRE HOSES TO CORRECT LENGTH OF 50'.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 20 March 1996 Resolved
REPLACE LINE ATTACHED TO RING BUOYS TO PROPER LENGTH OF 90'.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Electrical
Issued 20 March 1996 Resolved
REPLACE MISSING SIDE PANELS TO ELECTRICAL BOX IWO 3RD DK LADIES RESTROOM.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Electrical
Issued 20 March 1996 Resolved
PROPERLY LABEL BREAKER DIRECTORY FOR ELECTRICAL PANELS # 407-408 IWO 3RD DKLADIES RESTROOM.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Navigation
Issued 20 March 1996 Resolved
PROVE PROPER OPERATION OF STBD Z-DRIVE THRUST DIRECTION INDICATOR.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Navigation
Issued 20 November 1995 Resolved
PROVIDE RULES OF THE ROAD AND NOTICE TO MARINERS FOR PILOT HOUSE.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Fire Fighting
Issued 20 November 1995 Resolved
PROVIDE BRONZE CAP FOR PORT FIREMAIN SHORE CONNECTION. (MAIN DECK)
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Fire Fighting
Issued 20 November 1995 Resolved
RENEW CO2 PLACARD LOCATED ON EXTERIOR SIDE OF MAIN DECK E/R (PORT)
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Unknown
Issued 20 November 1995 Resolved
PROPERLY SECURE FOOT LOCKERS IWO MAIN DECK (STERN)
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Fire Fighting
Issued 20 November 1995 Resolved
ADJUST FIRE SCREEN DOORS IWO ELEVATORS SHAFT TO ALLOW FOR FULL CLOSURE - (4TH DECK)
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Accommodation/Occupational Safety
Issued 20 November 1995 Resolved
MARK AND LABEL EMERGENCY ESCAPE HATCHS IAW 46 CFR 78.47-40.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Documentation
Issued 20 November 1995 Resolved
PROVIDE/POST EMERGENCY CHECK OFF LIST
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Engineering
Issued 10 August 1995 Resolved
PROVE OPERATION OF OVERSPEED TRIP SOLENOID ON #2 MDE.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Electrical
Issued 10 August 1995 Resolved
PROVE OPERATION OF PUBLIC ADDRESS SYSTEM UNDER EMERGENCY POWER. DURING TESTOF EMERGENCY SYSTEMS PA SYSTEM WAS INOPERATIVE.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Fire Fighting
Issued 10 August 1995 Resolved
PROVE PROPER OPERATION OF FWD FSD'S 3RD DECKAND AND STBD 2ND DECK.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Fire Fighting
Issued 10 August 1995 Resolved
PROVE PROPER OPERATION OF AUTOMATIC LOUVERS IN EDG SPACE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Accommodation/Occupational Safety
Issued 10 August 1995 Resolved
PROVE ALARM OPERATION AND PROVIDE ANNUAL SERVICE CERTIFICATION PAPERWORK TOCG.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Electrical
Issued 10 August 1995 Resolved
REPLACE INOPERATIVE REVERSE POWER RELAYS ON #2 & #3 GEN/PANEL BOARD & PROVESAT. REPLACE OVERSPEED TRIP SOLENOID ON #1 GEN/SET. REPLACE HW TEMP PROBE ON #3 GEN/SET. ONLY ONE GEN SET TO BE PLACED IN OPERATION AT A TIME. VSL NOT TO CARRY PASSENGERS U/W UNTIL REPAIRS TEST SAT.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Electrical
Issued 10 August 1995 Resolved
PROVE OPERATION OF LOW OIL PRESSURE SWITCH AND HW TEMP PROBE ON EDG.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Accommodation/Occupational Safety
Issued 26 May 1995 Resolved
ADD ADDITIONAL RUNGS TO BOTTOM OF LADDER LEADING INTO CO2 ROOM.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Documentation
Issued 26 May 1995 Resolved
PROVIDE PROOF OF EMPLOYEE PARTICIPATION IN ANNUAL RANDOM DRUG/CHEMICAL TESTING.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Electrical
Issued 26 May 1995 Resolved
MARK ALL EMERGENCY LIGHTING WITH A RED "E".
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Accommodation/Occupational Safety
Issued 26 May 1995 Resolved
MARK "EMERGENCY EXIT, DO NOT BLOCK" ON MAT COVERING ESCAPE HATCH ON FIRST DECK STBD.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Fire Fighting
Issued 26 May 1995 Resolved
PROVE PROPER CLOSURE OF FSD #2, FORWARD STBD FSD 1ST DECK AND FORWARD PORT FSD 2ND DECK.
Condition: Unknown
Due 26 May 1995
Resolved 26 May 1995
Electrical
Issued 9 February 1995 Resolved
CONDUCT REVERSE POWER RELAY TESTS ON ALL SHIPS SERVICE GENERATORS.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Electrical
Issued 9 February 1995 Resolved
PROVE OPERATION OF EMERGENCY GENERATOR BY PERFORMING 1 HOUR OPERATIONAL TEST.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Engineering
Issued 9 February 1995 Resolved
CONDUCT ALL SAFETY CHECKS ON MDE'S AND SSG'S, I.E., OVERSPEEDS, LOW OIL PSIHIGH JACKET WATER TEMP, ETC.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Fire Fighting
Issued 9 February 1995 Resolved
PROVE OPERATION OF VESSEL SPRINKLER SYSTEM BY PERFORMING ZONE ACTIVATION TESTS.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Construction/Loadline
Issued 9 November 1994 Resolved
MATCH HYDRAULIC WTD NUMBERS BETWEEN DOOR AND BRIDGE CONTROL.
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Construction/Loadline
Issued 9 November 1994 Resolved
REPAIR MALFUNCTIONING WTD INDICATOR FOR WTD LEADING TO FWD COMPARTMENT.
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Accommodation/Occupational Safety
Issued 9 November 1994 Resolved
PROVIDE STABLE PLATFORM FOR ALL CUSTOMER TV'S LOCATED THRU-OUT CASINO.
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Electrical
Issued 9 November 1994 Resolved
LABLE BREAKER USE FOR ELECTRICAL PANEL LOCATED FWD LOCKER ROOM, PORT SIDE AFTER BULKHEAD.
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Lifesaving
Issued 9 November 1994 Resolved
INSTALL EMERGENCY EXIT DIRECTIONAL SIGN INDICATING LOCATION, LEAVE DOOR TO ROOM EXIT IS LOCATED IN IN THE UNLOCKED POSITION.
Condition: Unknown
Due 9 November 1994
Resolved 9 November 1994
Documentation
Issued 20 September 1994 Resolved
UPDATE VESSEL FIRE SAFETY PLAN, DISTRIBUTE TO VESSEL AND ONE (1) COPY TO MSO ST LOUIS.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Accommodation/Occupational Safety
Issued 20 September 1994 Resolved
REPLACE SHATTERED PLATE GLASS WINDOW IN 1ST DECK SLIDING DOOR WHEN GLASS ISRECEIVED.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Fire Fighting
Issued 11 August 1994 Resolved
Bring fwd hold storeroom, fwd bulkhead up to A-60 standards by installing approved insulation 12" down from overhead.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Lifesaving
Issued 11 August 1994 Resolved
Submit to OCMI an alternate method to enter rescue boat during emergency evolutions. Present way poses greater danger to personnel tasked with the rescue of passengers that may have fallen overboard than possible repositioning of access ladder.
Condition: Unknown
Due 11 August 1994
Resolved 11 August 1994
Lifesaving
Issued 11 August 1994 Resolved
Install lighted exit sign in fwd food prep room, hold area.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Fire Fighting
Issued 11 August 1994 Resolved
Contact local fire dept to insure that their equipment matches vessel firemain shore connections.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Lifesaving
Issued 11 August 1994 Resolved
relocate "manual fire damper" sign to area just below ceiling tile that damper is located behind.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Unknown
Issued 11 August 1994 Resolved
Install Garbage Pollution placards on vessel.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Documentation
Issued 11 August 1994 Resolved
Install oil pollution placards in vicitity of bilge pump/controler.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Documentation
Issued 11 August 1994 Resolved
Present vessel oil transfer procedures for CG review.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Accommodation/Occupational Safety
Issued 11 August 1994 Resolved
Install emergency telephone in passenger elevator.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Accommodation/Occupational Safety
Issued 11 August 1994 Resolved
Remove supplies/boxes from stbd elevator machinery room in hold.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Unknown
Issued 11 August 1994 Resolved
Properly lable unknown lines and valves in trash room off main deck.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Engineering
Issued 11 August 1994 Resolved
Replace all fuel and oil hoses meeting SAE J-1402 with approved hoses that meet SAE J-1942 standards that are installed on any internal combustion engine.
Condition: Unknown
Due 11 August 1994
Resolved 11 August 1994
Electrical
Issued 11 August 1994 Resolved
Lable electrical panel, identify breakers in panel in trash room off main deck.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Unknown
Issued 11 August 1994 Resolved
Mark off/rope off area in immediate vicinity of pilothouse, area to be off limits to passengers.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Electrical
Issued 11 August 1994 Resolved
Have all "E" lights tested during power outage.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Fire Fighting
Issued 11 August 1994 Resolved
Replace missing sections of insulation in overhead of food prep area fwd port side, on longitudinal stiffners.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Fire Fighting
Issued 11 August 1994 Resolved
Install approved insulation 12" down from main deck on both P & S of fwd storeroom, bring up to A-60 standard.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.