This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
532 - Regulatory (Subpart C or D), Net Ton
532 - Regulatory (Subpart C or D), Gross Ton
Maury page id
psix-40897
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
CROP AND RENEW TO GOOD METAL, AREA OF DECK PLATE ALONG CENTERLINE OF CARGO TANK BLOCK WHERE WASTED THIN, AS DETERMINED BY ULTRASOUND GAUGING.
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Construction/Loadline
Issued 10 March 1994Resolved
UPON OFFLOADING CARGO, PRIOR TO RELOADING, PERMANENTLY REPAIR 3" DECK FRACTURE AT BASE OF PV VALVE MOUNT IN WAY OF NO. 2 PORT CARGO TANK.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Deck/Cargo
Issued 10 March 1994Resolved
RESTORE CARGO PUMP ENGINE HYDRAULIC STARTING SYSTEM TO ORIGINAL CONDITION. DISCONTINUE INSTALLATION OF ELECTRICAL STARTING SYSTEM UNTIL PLANS ARE SUBMITTED AND APPROVED BY THE COGNIZANT OCMI.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Deck/Cargo
Issued 26 December 1991Resolved
PRIOR TO THE USE OF THE CARGO PUMP ENGINE, PROVE PROPER OPERATION OF THE EMERGENCY SHUT DOWN IN ACCORDANCE WITH 46 CFR 32.50-35.
Condition: Unknown
Due 26 January 1992
Resolved 30 December 1991
Construction/Loadline
Issued 3 February 1987Resolved
PERMANENTLY REPAIR 12" SEMI-CIRCULAR FRACTURE IN STARBOARD STERN LOG, 4' INBOARD AND 2' DOWN FROM DECK, AT THE NEXT GAS-FREE PERIOD BUT NOT LATER THAN 03AUG87.
Condition: Unknown
Due 3 February 1987
Resolved 3 February 1987