Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named MONSTER
MONSTER is a 1994 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1994, most recently in July 2026, along with 159 deficiencies, 1 operational control and 2 casualty investigations between 2017 and 2024.
Records from 1994 to 2026. Most recent: inspection, 28 July 2026.
- Built
- 1994
- Last inspected
- 28 July 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 159 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2017–2024
Identity
1024119
WDJ5255
409035
Flag
UNITED STATES
367046450
Maury page id
psix-409035
Inspections, by type
…with no type recorded12
Years with a record
27 calendar years (1994–2026)
The 65 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)52.5 ft × 15.4 ft × 5.3 ft
Registered tonnagegross 28 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLENN YOUNG BOATS · OCEAN SPRINGS, MS, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAVANNAH, GA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 21 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Net Ton
28 - Simplified, Gross Ton
28 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ5255MMSI 367046450 · active · compulsorily equipped · granted 2 May 2017, expires 2 May 2027
WDC5789MMSI 367046450 · expired · compulsorily equipped · granted 1 June 2005, cancelled 1 August 2015 · licensed under a name not among this hull’s recorded names (not shown)
WCN2662MMSI not assigned · expired · compulsorily equipped · granted 1 October 1994, cancelled 4 December 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 65
28 July 2026
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8448872
28 July 2025
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8196834
21 January 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8067007
26 December 2024
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8051133
19 July 2024
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7962096
12 April 2024
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7894515
12 April 2024
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7897603
10 August 2023
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7764556
19 January 2023
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7622149
11 May 2022
COI Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7448222
11 March 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7154584
19 February 2021
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7143054
28 January 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7132639
11 February 2020
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6904600
28 August 2019
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6797485
19 August 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6775588
24 May 2019
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6692276
26 April 2019
Deficiency Check · Special · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6671134
15 August 2018
DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6513302
23 January 2018
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6344208
15 November 2017
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6307088
12 September 2017
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6266234
28 August 2017
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6266231
25 July 2017
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6220534
10 May 2017
Hull Examination · Simplified Stability Test · Initial Certification · Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6149916
14 March 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6104380
23 October 2014
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5010668
16 July 2012
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4341060
31 August 2011
Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4132171
14 January 2011
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3930706
29 November 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3106647
24 July 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3005957
16 May 2007
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2932295
31 July 2006
Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2732856
16 June 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2392599
7 June 2005
COI Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2391112
12 May 2005
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2333298
10 August 2004
Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2161583
29 August 2003
Deficiency Check · MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1890651
28 May 2003
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1803568
25 August 2002
Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1666030
4 October 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1074498
30 May 2001
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1391600
1 March 2001
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1058157
2 August 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1053415
6 June 2000
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 818991
10 June 1999
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1472155
1 June 1999
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1451407
31 August 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 798529
27 May 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 791823
31 July 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1119491
11 June 1997
Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1375028
27 August 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 703147
11 June 1996
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1419623
10 June 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 175546
9 June 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 26664
3 March 1996
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 100052
3 March 1996
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 116357
14 September 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1462460
20 April 1995
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1172604
4 March 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 886224
5 December 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1181713
31 August 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1181410
18 August 1994
Hull Examination · Initial Construction-Excluding Oversight · Plan Review "T" Boat · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 870444
3 August 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1456192
Deficiency record · 159
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 28 July 2026
Resolved
33CFR151.10 (b) When within 12 nautical miles of the nearest land, any discharge of oil or oily mixtures into the sea from a ship other than an oil tanker or from machinery space bilges of an oil tanker is prohibited except when all of the following conditions are satisfied—
(1) The oil or oily mixture does not originate from cargo pump room bilges;
(2) The oil or oily mixture is not mixed with oil cargo residues;
(3) The oil content of the effluent without dilution does not exceed 15 ppm;
(4) The ship has in operation oily-water separating equipment, a bilge monitor, bilge alarm, or combination thereof as required by part 155 subpart B of this chapter; and
(5) The oily-water separating equipment is equipped with a 15 ppm bilge alarm; for U.S. inspected ships, approved under 46 CFR 162.050 and for U.S. uninspected ships and foreign ships, either approved under 46 CFR 162.050 or listed in the current International Maritime Organization (IMO) Marine Environment Protection Committee (MEPC) Circular summary of MARPOL 73/78 approved equipment.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 January 2025
Resolved
THE OWNER SHALL MAKE A VESSEL AVAILABLE FOR DRYDOCK EXAMS AND INTERNAL STRUCTURAL EXAM. THE FOLLOWING WORKLIST ITEMS NEED TO BE COMPLETED PRIOR TO CREDIT DRY DOCK.
a) REPAIR DAMAGED FIBERGLASS ON BOW
b) RENEW STARBOARD BEARING ON PROP
c) PROVIDE VISUAL INSPECTION OF PORT RAW WATER VALVE
d) SECURE CANOPY TO DECK HOUSE.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 December 2024
Resolved
26DEC24: Received a duty call on the Small passenger vessel "T" Monster wth a report of hitting the south jetti on Savannah River with 34 passengers onboard and 2 crewmembers. Vessel dropped anchor when engines shutdown. Master tried starting both engines before realzing the engines were still clutched in. After throttles were placed back in neutral postion, engines were re-started. Master and crew verified vessel was not taking on water and headed back to dock. Master reported minimal vibration on starboard engine on return trip. Passeners disembarked vessel and owner [name withheld] will conduct diving operations on 27DEC24 to identify damage. Master thinks that the starboard propeller may have been damaged. Issued no sail code 701c CG-835V.
(01) Deficiencies issued
(00) Deficiencies cleared
(01) Deficiencies remain outstanding
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 July 2024
Resolved
Replace retro-reflective tape on (2) ring life bouys
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 19 July 2024
Resolved
Re-route control cable away from belt pulley on forward port engine.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 July 2024
Resolved
Provide means to connect and hold open stbd side engine room emergency vantilation closure flap.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 July 2024
Resolved
Re-connect ground cable on stbd side battery box that was disconnected or remove if no longer necessary.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 July 2024
Resolved
Secure all engine room wireing with proper cable clamps IAW USCG standards. Also remove any engine room cable clamps no longer in use.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 April 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The starboard engine secondary fuel filter split causing a loss of propulsion, repair in kind to the satisfaction of the cognizant OCMI prior to the carriage of passengers.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 August 2023
Resolved
47 CFR 80.411:COMMS ACT CERT: 01199 Provide a Communications Act, Safety Radiotelephony Certificate in accordance with 47 CFR 80.411 to the satisfaction of an attending Coast Guard Marine Inspector. The vessel will be restricted from carrying passengers after 9SEP2023 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 May 2022
Resolved
47 CFR 80.59 Vessels radio installation certificate is expired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 May 2022
Resolved
182.720(e) (2) Flexible hose may be used provided it is fitted with suitable connection fittings and has high resistance to saltwater, petroleum oils and vibration. Port side fuel supply hose in fuel tank space is worn and needs to be replaced.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 28 January 2021
Resolved
46 CFR 176.25-35 (a)
The STBD rudder upper bearing support housing was found split.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 28 January 2021
Resolved
176.25-5(a)1
In the lazarette a deck support 2x4 on the port side just off centerline was found split causing the deck to flex in the area when walked on.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 February 2020
Resolved
Diesel fuel flexible hose shall be fabricated with an inner tube and a cover of synthetic rubber or other suitable material reinforced with wire braid. Vessel utilized approximately 33 feet of electrical tape as a soft patch on a diesel fuel flexible hose on the starboard engine in the engine room. Upon removal of the tape, the wire braid was showing (roughly the size of a quarter) and the hose was leaking a solid stream of diesel. 46CFR182.20-40 (a)(2)(ii)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 February 2020
Resolved
Vital systems on mechanically propelled vessels which carry more than 49 passengers shall comply with the provisions of Subchapter F of this chapter. Vessel utilized electrical tape as a soft patch on a metallic raw water pipe on the starboard engine in the engine room. Upon removal of the tape, a solid stream of raw water was leaking in to the bilge. 46CFR182.40-5 (b), 46 CFR 56.10-1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 February 2020
Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test….The means provided for pumping bilges. Vessel rep could not properly demonstrate operational test of individual bilge lines and bilge suctions. 46 CFR 176.25-10(a)(7)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 11 February 2020
Resolved
Suitable storm rails or hand grabs shall be installed where necessary in all passageways, at deckhouse sides, and at ladders and hatches where passengers or crew might have normal access. The storm rails in way of the steps that lead to the forward passenger accommodation area on the starboard side was damaged at the base and loose creating a potential hazard. 46 CFR 177.35-5.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 February 2020
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. There are a total of 22 adult life jackets that are stowed underneath the benches in the forward fixed seating within the benches that were not marked. Vessel is restricted to a maximum of 40 passengers until deficiency is rectified. 46 CFR 185.604 (f) and 46 CFR 185.115(b)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2020
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that a fire drill be held under simulated emergency conditions to be specified by the inspector. Vessel unable to conduct underway drills due to starboard main engine deficiencies found. 46CFR176.810(d)
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 11 February 2020
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Vessel unable to conduct underway drills due to starboard main engine deficiencies found. 46CFR176.808(g)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2020
Resolved
Whenever there is a hazardous condition, on board the vessel, the owner, master, agent, or person in charge shall immediately notify the Captain of the Port of the port of place of destination and the Captain of the Port of the port or place in which the vessel is located of the hazardous condition. Safety of the vessel was jeopardized after temporary repairs were made on the fuel oil and raw water vital systems without approval from OCMI. 46CFR185.203
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 February 2020
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Temporary repairs were made on the fuel oil and raw water vital systems without approval from OCMI. 46CFR176.700(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 August 2019
Resolved
Vessels indicator light for Class 1 watertight door for the bridge is not working as required by 46CFR170.255(e). The vessel will be restricted from carrying passengers after August 30, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 August 2019
Resolved
Vessels Class 1 watertight door is not closing correctly as required by 46CFR170. 270. The vessel will be restricted from carrying passengers after August 30, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 August 2018
Resolved
Prior to Carrying Passengers,demonstrate proper operation of the pre-engineered (Fireboy) fire extinguishing system protecting the machinery space in accordance with 46 CFR 181.420
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 August 2018
Resolved
Make permanent repairs to the automatic, electric bilge pump located in the lazarette in accordance with 46 CFR 182.520. Crew made temporary wiring to ensure pump would activate in case of high water level; however, permanent repairs will be required no later than September 5, 2018. The vessel will be restricted from carrying passengers after that date if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 August 2018
Resolved
Properly affix retro-reflective material on three (03) life jackets in accordance with 46 CFR 185.604(h) and IMO Resolution A.658(16). The vessel will be restricted from carrying passengers after September 5, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 August 2018
Resolved
Properly mark all life jacket storage
containers/locations in accordance with 46 CFR 180.78 and 46 CFR 185.604(f) with the type life jacket (adult or child) and the quantity. The vessel will be restricted from carrying passengers after September 5, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 22 August 2018
Resolved
Remove all standing fuel in the flame impingement bowls in way of the fuel filters in accordance with 46 CFR 176.800(a). The vessel will be restricted from carrying passengers after September 5, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 August 2018
Resolved
Properly post the Certificate of Inspection and the Stability Letter under glass or other suitable transparent material in accordance with 46 CFR 176.302 and 46 CFR 176.306. The vessel will be restricted from carrying passengers after September 5, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 August 2018
Resolved
Identify the leak and make permanent repairs to the section of pipe observed leaking in way of the port side Main Diesel Engine's power take of pump servicing the fire and bilge pump in accordance with 46 CFR 181.310(b). The vessel will be restricted from carrying passengers after September 5, 2018 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector. (EXTENDED UNTIL SEPTEMBER 19, 2018)
Construction/Loadline › Hull › Side Shell
Issued 12 September 2017
Resolved
Vessels hull was damaged during Hurricane Irma and does not meet the structural design requirements per 46CFR177.300(c). Provide repair plan proposal to the Coast Guard and receive approval for repairs from the Coast Guard as described in 46CFR176.700 and carry out repairs after approval is received . Vessel restricted from carrying passengers until corrected to the satisfaction of the attending M
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 28 August 2017
Resolved
Vessels main engine suffered a casualty which made the engine non operational which does not meet the propulsion requirements per 46CFR182.200(a). Provide repair plan / continued operation proposal to the Coast Guard and restore main engine to suitable operations in the presence of a marine inspector prior to carrying passengers.
Lifesaving › Lifebuoys › Serviceable
Issued 22 May 2017
Resolved
Replace ring life buoy retro reflective tape with type II retro reflective material per 46CFR185.604 (i)
Communications › Alarms/Indicators › High Water Alarm
Issued 22 May 2017
Resolved
Provide visual high level alarm for aft compartment per 46CFR 182.530(c)
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 May 2017
Resolved
Provide first aid kit per 46CFR160.041
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 May 2017
Resolved
Provide stern and masthead light per 46CFR183.470
Communications › Radio Communications › VHF Radiotelephone
Issued 22 May 2017
Resolved
Provide MMSI input on VHF 46CFR80.933
Communications › Radio Communications › Satellite Communications Capability
Issued 22 May 2017
Resolved
Ensure CA safety certificate encompasses inspection of vessel up to 100 NM. 47CFR80.903
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 31 August 2011
Resolved
Replace 26 deteriorated life jackets and retape 9 life jackets with retro feflective tape as discussed.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 31 August 2011
Resolved
Post emergency instructions IAW with 46 CFR 185.510
Documentation › Logs/Records › Drug Test Records
Issued 31 August 2011
Resolved
Provide drug consordium cards for 100% of the crew.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 31 August 2011
Resolved
Prove proper operation of hatch cover to fuel room.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 31 August 2011
Resolved
Provide CPR and First Aid cards for 50% of the crew.
Engineering › Bilge Water Management System › Piping
Issued 24 July 2007
Resolved
Prior to completion of next credit drydock, replace flex hose in way of fixed bilge piping aft of collision bulkhead.
Engineering › Bilge Water Management System › Manifold
Issued 24 July 2007
Resolved
Replace valve handle in way of forward compartment bilge at manifold.
Stability › Weathertight Integrity › General
Issued 16 May 2007
Resolved
Replace missing gasket on hatch cover (lazarette).
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2007
Resolved
Remove or properly cap dead-end wires IWO float switch on stbd side of fuel tank.
Engineering › Steering Gear System › Hydraulic Hose
Issued 16 May 2007
Resolved
Replace fittings on hydraulic hose to steering gear (lazarette).
Stability › Weathertight Integrity › General
Issued 16 May 2007
Resolved
Replace gasket on fuel tank space hatch.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 16 May 2007
Resolved
Replace all cutlass bearings.
Engineering › Bilge Water Management System › Hose
Issued 16 May 2007
Resolved
Provide documentation for flexhose in bilge piping for space aft of collision bulkhead.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 16 May 2007
Resolved
Investigate source of leak in MSD space and make proper repairs. Clean bilge.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 16 May 2007
Resolved
Clean oil from bilge in stearing gear room.
Construction/Loadline › Hull › Hull Plating
Issued 16 May 2007
Resolved
Make proper repairs to cracks in forward stbd shaft strut.
Stability › Weathertight Integrity › General
Issued 16 May 2007
Resolved
Prove proper operation of fuel space hatch.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 31 July 2006
Resolved
Inspectors removed/destroyed 18 child and 22 adult life jackets. 22 adult life jackets required to meet 56 adult life jackets required by COI. Vessel operation restricted to 34 adult persons on board until life jackets replaced.
Communications › Radio Communications › EPIRB
Issued 31 July 2006
Resolved
Battery for EPIRB is missing expiration date. Replace battery or provide proof of date battery placed into service.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 31 July 2006
Resolved
Stencil vessel name on ring life buoy.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 31 July 2006
Resolved
Re-connect port engine shutdown cable.
Engineering › Lubricating Oil Service System › Gauge
Issued 31 July 2006
Resolved
Mount lube oil pressure gauge on starboard main diesel engine.
Engineering › Bilge Water Management System › Not Installed
Issued 31 July 2006
Resolved
Permanently mount bilge high level alarm panel.
Engineering › Bilge Water Management System › Strainer
Issued 31 July 2006
Resolved
Install bilge strainer in engine room bilge.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 June 2005
Resolved
Properly terminate dead-end wires in forepeak.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 June 2005
Resolved
Properly terminate dead-end wires in fuel tank space.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 June 2005
Resolved
Properly terminate dead-end wires in E/R. (Port/stbd main diesel engines)
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 August 2004
Resolved
Post COI so that all pages are visible.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 10 August 2004
Resolved
Provide CPR training for master and crew.
Documentation › Certificates/Documents › FCC SSL
Issued 10 August 2004
Resolved
Provide current marine radio operators permit. Vessel is restricted to less than 1000 feet from shore until permit is presented to CG MI.
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 August 2004
Resolved
Provide proof (log entry) for all vessel training and drills (MOB and fire).
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 10 August 2004
Resolved
Provide proper operation of horn.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 10 August 2004
Resolved
Provide 3 additional orange flares or 6 additional red flares. Vsl is restricted to LBS route until additional flares are verfified by CG MI.
Lifesaving › Lifefloat › Serviceable
Issued 10 August 2004
Resolved
Make proper repairs to LF's. Patch, repaint.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 August 2004
Resolved
Make proper repairs to water lights on Port LF.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 August 2004
Resolved
Replace retroreflective tape on approximately 30 lifejackets.
Lifesaving › Lifebuoys › Serviceable
Issued 10 August 2004
Resolved
Replace life ring on port side.
Fire Fighting › Fire Main › Condition
Issued 10 August 2004
Resolved
Double clamp intake and discharge hoses for Fire Pump.
Fire Fighting › Fire Main › Condition
Issued 10 August 2004
Resolved
Replace Fire Pump suction hose. (located port side of fire pump)
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 August 2004
Resolved
Place cover on battery boxes.
Engineering › Bilge Water Management System › Strainer
Issued 10 August 2004
Resolved
Properly repair strainer on fore peak bilge suction line.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 August 2004
Resolved
Properly repair exposed wiring to trim equipment in lazarette.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 10 August 2004
Resolved
Clean engine compartment bilges.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 August 2004
Resolved
Straighten out wiring in stbd electrical compartment. No dead end wiring. All wire connections should be in an electrical box.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 10 August 2004
Resolved
Properly repair port MDE water pump.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 29 August 2003
Resolved
Vsl's fixed clean agent fire extinguishing system for E/R failed to shut down either engine during test. LEGACY COMPONENT DESC: Engine Shutdowns
Electrical
Issued 29 August 2003
Resolved
Remove or properly terminate dead end wiring in fwd below deck area just aft of fresh water tank. LEGACY COMPONENT DESC: Dead end wiring
Electrical
Issued 29 August 2003
Resolved
Remove or properly terminate dead end wires in below deck space adj to forwardmost access hatch. LEGACY COMPONENT DESC: Dead end wiring
Electrical
Issued 29 August 2003
Resolved
Properly enclose open electrical instrument panel at operating station. LEGACY COMPONENT DESC: Open Instrument Panel
Electrical
Issued 29 August 2003
Resolved
Remove all extension cords/power strips in e/r. LEGACY COMPONENT DESC: Electrical Wiring
Electrical
Issued 29 August 2003
Resolved
Remove or properly terminate dead end wires above stbd 12V battery in e/r. LEGACY COMPONENT DESC: Dead end wiring
Navigation › Collision/Grounding Avoidance › Radar
Issued 29 August 2003
Resolved
Re-install missing radar.
Navigation › Piloting/Steering › Marine Charts
Issued 29 August 2003
Resolved
Update nav charts.
Communications › Radio Communications › EPIRB
Issued 29 August 2003
Resolved
Renew expired NOAA Registration.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 August 2003
Resolved
Repair aft deck rail missing stanchion.
Engineering
Issued 29 August 2003
Resolved
Repair water leak from stbd engine cooling water heat exchanger. LEGACY COMPONENT DESC: Heat exchanger
Engineering › Bilge Water Management System › Piping
Issued 29 August 2003
Resolved
Repair leaking bilge suction pipe.
Construction/Loadline › Hull
Issued 29 August 2003
Resolved
Provide proposal to address stress cracks identified P/S fwd bulwarks. LEGACY COMPONENT DESC: Bulwarks
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 August 2003
Resolved
Double hose clamp all primary cooling system flex hoses.
Accommodation/Occupational Safety › Occupational Safety
Issued 28 May 2003
Resolved
Repairs made to rails in drydock. Side rails required to be installed prior to carrying passengers. Aft rails required to be installed by date indicated. Crew must man embarkation deck while loading and unloading passengers until aft rails are installed. LEGACY COMPONENT DESC: Deck Rail
Construction/Loadline › Penetrations
Issued 28 May 2003
Resolved
Repair/replace starboard fly bridge louvers. LEGACY COMPONENT DESC: Vent louvers
Engineering › Fuel Oil Storage/Transfer System
Issued 28 May 2003
Resolved
Permanently/properly support fuel tank. [name withheld] to submit fuel tank support repair proposal to ActNY Plan Review. Once approval has been obtained a due date will be assigned. Temp. support required until then. LEGACY COMPONENT DESC: Tank
Electrical › Electric Generation Source (service)
Issued 28 May 2003
Resolved
Fasten battery boxes as needed. LEGACY COMPONENT DESC: Battery
Construction/Loadline › Hull
Issued 28 May 2003
Resolved
Repair fractured underdeck longitudinal frame in lazarette/fuel tank space on starboard side of aft hatch and IWO transom. LEGACY COMPONENT DESC: Longitudinal Frame
Electrical › Electrical Distribution System (service)
Issued 28 May 2003
Resolved
Properly support wires running through tank space to bilge pump/alarms etc. LEGACY COMPONENT DESC: Wiring
Lifesaving
Issued 19 August 2002
Resolved
Replace life line on STBD side life bouy.
Lifesaving
Issued 19 August 2002
Resolved
Replace B/A light stern BA, (innermost light), in row of three per side.
Electrical
Issued 30 May 2001
Resolved
Remove or properly terminate deadend wiring.
Construction/Loadline
Issued 30 May 2001
Resolved
Permanently repair forward bulwark IWO focile and also deck area in midpartof focile 2 ft forward of bridge.
Electrical
Issued 30 May 2001
Resolved
Battery terminals severely corroded. Clean and ensure proper contact of terminals.
Navigation
Issued 30 May 2001
Resolved
Reinstall the radar._x001C_ _x001C_ Vessel must comply with 46CFR184.404 as determined by OCMI in accordance with 46CFR184.115(a) due to route, high traffic area, and speed of vessel.
Fire Fighting
Issued 30 May 2001
Resolved
Prove proper operation of FIREBOY alarm and engine shutdown/bypass switch.
Fire Fighting
Issued 30 May 2001
Resolved
Prove proper operation of bilge/fire pump.
Engineering
Issued 30 May 2001
Resolved
Make flame screens available for inspection.
Engineering
Issued 30 May 2001
Resolved
Prove proper operation of Main diesel engines.
Engineering
Issued 30 May 2001
Resolved
2 Engine mounting bolts are loose. Tighten and check all remaining mounts with wrench.
Lifesaving
Issued 30 May 2001
Resolved
Properly stow lifefloat in a float-free arrangement.
Accommodation/Occupational Safety
Issued 6 June 2000
Resolved
REPAIR FWD ATHWARTSHIPS DECK RAIL.
Lifesaving
Issued 6 June 2000
Resolved
REPLACE RETRO TAPE ON LIFE JACKETS AND LIFE FLOATS AS NEEDED.
Construction/Loadline
Issued 6 June 2000
Resolved
FILL HOLES IN STBD SIDE OF ENGINE ROOM / LAZARETTE BULKHEAD.
Construction/Loadline
Issued 6 June 2000
Resolved
REPAIR AND TEST #2 COMPARTMENT ELECTRICAL SUBMERSIBLE BACKUP BILGE PUMP.
Construction/Loadline
Issued 6 June 2000
Resolved
MAKE #2 COMPARTMENT FIXED BILGE SUCTION AVAILABLE FOR INSPECTION, AND CONDUCT SATISFACTORY TEST OF THIS SUCTION LINE.
Fire Fighting
Issued 6 June 2000
Resolved
PROVIDE MEANS OF CLOSING AFT ENGINE ROOM VENTS (TWO - NATURAL VENTILATION) WHEN FIRE BOY SYSTEM ACTIVATED. PROVIDE TEMP MEANS OF CLOSING VENTS UNTIL PERMANENT COVERS OBTAINED.
Documentation
Issued 6 June 2000
Resolved
PROVIDE VALID FCC SAFETY CERTIFICATE (EXPIRED). RESTRICTED TO LESS THAN 1000 FEET FROM SHORE UNTIL PROVIDED.
Engineering
Issued 6 June 2000
Resolved
REPLACE MISSING PORT SIDE FUEL TANK VENT FLAME SCREEN & HOUSING.
Fire Fighting
Issued 1 June 1999
Resolved
PILOT HOUSE FFF SYSTEM (FIREBOY) HAS NO AUDIO ALARM PLUS THE PULL CABLE NEEDS TO BE TESTED DUE TO CORROSION.
Construction/Loadline
Issued 1 June 1999
Resolved
BILGE PUMP LOCATED IN LAZ NEEDS CRIMP WIRE NUTS INSTALLED.
Electrical
Issued 1 June 1999
Resolved
UNDER ELECTRICAL PANEL ON BRIDGE REMOVE OR CRIMP ALL DEAD ENDED WIRING.
Engineering
Issued 1 June 1999
Resolved
REPLACE STBD ENGINE OUTBOARD FWD CHAULK._x001C_ (NO-SAIL)
Electrical
Issued 1 June 1999
Resolved
REPLACE MISSING LIGHT COVER IN STBD CREW HEAD.
Engineering
Issued 1 June 1999
Resolved
INSTALL GROUNDING STRAP TO FUEL TANK LOCATED IN FWD LAZ COMPARTMENT.
Navigation
Issued 1 June 1999
Resolved
REPAIR RUDDER ANGLE INDICATOR OR REMOVE.
Construction/Loadline
Issued 1 June 1999
Resolved
AUDIO AND VISUAL BILGE ALARMS PROVIDE NEED APPROVED PLANS IAW 46 CFR 182.530.
Lifesaving
Issued 1 June 1999
Resolved
WEAK LINK FOR PORT SIDE TOP L/F LINE NEEDS REPLACING (BROKEN).
Lifesaving
Issued 27 May 1998
Resolved
PROPERLY STENCIL ALL LIFESAVING GEAR WITH VESSEL'S NEW NAME
Lifesaving
Issued 27 May 1998
Resolved
REGISTER EPIRB WITH NOAA
Lifesaving
Issued 11 June 1997
Resolved
PROVIDE EVIDENCE THAT 50% OF THE CREW HAVE VALID FIRST AID AND CPR TRAINING/CARDS._x001C_ NVIC 1-91
Documentation
Issued 11 June 1997
Resolved
PROVIDE ON BOARD VESSEL, A VALID FCC OPERATORS LICENSE._x001C_ 47 CFR 80.155_x001C_ _x001C_ _x001C_
Documentation
Issued 11 June 1997
Resolved
PROVIDE AND POST A VALID STABILITY LETTER._x001C_ 46 CFR 176.306
Lifesaving
Issued 11 June 1997
Resolved
PROVIDE ON BOARD VESSEL, SIX RED NIGHT FLARES._x001C_ 46 CFR 180.68
Lifesaving
Issued 11 June 1997
Resolved
PROVIDE ON BOARD VESSEL, SIX ORANGE FLARES._x001C_ 46 CFR 180.68
Construction/Loadline
Issued 11 June 1997
Resolved
PROVIDE/INSTALL A POSITIVE ACTION VALVE LOCATED AS CLOSE TO THE HULL AS POSSIBLE FOR EACH SUBMERSIBLE BILGE PUMP DISCHARGE HOSE._x001C_ 46 CFR 171.119 (b)(c).
Navigation
Issued 11 June 1997
Resolved
PROVIDE ON BOARD VESSEL, ADEQUATE AND UP TO DATE NAUTICAL CHARTS AND PUBLICATIONS FOR THE VESSEL'S INTENDED AREA OF OPERATION._x001C_ 46 CFR 184.420
Lifesaving
Issued 11 June 1997
Resolved
CONDUCT A SATISFACTORY FIRE, ABANDON SHIP AND MAN OVERBOARD DRILL TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR._x001C_ 46 CFR 185.520/524
Documentation
Issued 11 June 1997
Resolved
PROVIDE AND POST AN EMERGENCY CHECK-OFF LIST._x001C_ 46 CFR 185.510
Documentation
Issued 11 June 1997
Resolved
PROVIDE ON BOARD VESSEL, AN UP TO DATE TRAINING LOG._x001C_ 46 CFR 185.420
Unknown
Issued 11 June 1996
Resolved
REWIRE VESSEL ELECTRICAL SYSTEM, WHICH WAS EFFECTED BY FIRE. REWIRING TO BEIAW VESSEL APPROVED PLANS.
Unknown
Issued 11 June 1996
Resolved
REPLACE ALL FUEL OIL, WATER SERVICE HOSES DAMAGE BY FIRE WITH APPROVED HOSES AS NEEDED.
Unknown
Issued 11 June 1996
Resolved
CONDUCT OPERATIONAL TEST OF THE FOLLOWING, MAIN ENGINE, GAUGES, ALARMS AND CONTROLS, NAV. LIGHTS AND GEAR.
Unknown
Issued 11 June 1996
Resolved
REPLACE/RECHARGE VESSEL FIRE EXTINGUISHING SYSTEMS.
Lifesaving
Issued 18 August 1994
Resolved
MARK CHILD LIFE JACKET STOWAGE
Navigation
Issued 18 August 1994
Resolved
PROVIDE CERTIFICATE OF ALTERNATIVE COMPLIANCE FOR NAVIGATION LIGHT LOCATIONS.
Lifesaving
Issued 18 August 1994
Resolved
COMPLETE MOUNTING OF WATER LIGHT BRACKETS.
Lifesaving
Issued 18 August 1994
Resolved
COMPLETE MOUNTING OF LIFE RINGS.
Engineering
Issued 18 August 1994
Resolved
COMPLETE INSTALLATION OF ENGINE ROOM VENT CLOSURE OPERATORS.
Documentation
Issued 18 August 1994
Resolved
PROVIDE FCC RADIO LICENSE.
Documentation
Issued 18 August 1994
Resolved
PROVIDE FCC SAFETY CERTIFICATE
Construction/Loadline
Issued 18 August 1994
Resolved
NO MORE THAN 49 PASSENGERS MAY BE CARRIED UNTIL THE BILGE PIPING IS REPLACED WITH METAL PIPE. ONCE COMPLETED SATISFACTORILY, THE VESSELS CERTIFICATE WILL BE AMENDED TO ALLOW -56- PASSENGERS.
Construction/Loadline
Issued 18 August 1994
Resolved
APPLY VESSEL'S NAME AND HAILING PORT TO STERN.
Casualty record · 2
25 July 2017Routine · role: Transiting Vicinity of Primary Subject · activity 6220534
12 April 2024Routine · role: Involved in a Marine Casualty · activity 7897603
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.