This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
70 - Regulatory (Subpart C or D), Net Ton
70 - Regulatory (Subpart C or D), Gross Ton
Maury page id
psix-40959
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 40
22 October 2019Administrative Inspection
Administrative · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6839588
23 July 2019Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6762907
22 March 2016Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5838034
13 January 2015Cargo Tank Internal · Construction Oversight · Examination of Repairs · COI Inspection · MTSA Verification · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5052673
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 22 March 2016Resolved
Had Approval letter but plan did not match.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 5 April 2016
Resolution: Verified VRP and approval letter matched, all sat.
Engineering › Fuel Oil Service System › Valve
Issued 15 December 2014Resolved
Fuel shutoff valve not installed correctly.
Due 15 January 2015
Resolved 3 March 2015
Resolution: Witnessed proper shutoff valves in place.
Missing four scupper plugs for hazardous waste containment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2012
Resolved 3 July 2013
Resolution: Scupper plugs replaced.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 11 September 2008Resolved
Mark cargo hoses IAW 33CFR155.800
Condition: Improper Installation
Due 11 October 2008
Resolved 15 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 September 2008Resolved
Remove starter, alternator, and any other electrical equipment in a class 1 Div 1 location IAW 111.105-31.
Condition: Improper Installation
Due 11 October 2008
Resolved 15 September 2008