Records from 2001 to 2002. Most recent: operational control imposed, 16 February 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 16 February 2002
Resolved
Inoperable Main Diesel Engine Turbocharger; SOLAS 74Am I/11; Provide Class report attesting to satisfactory repair and operation of MDE turbocharger.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2002
Resolved 19 February 2002
Resolution: Rcvd Class report citing that a new MDE turbocharger was installed w/proper operation.
Engineering
Issued 15 November 2001
Resolved
NO. 1 AND NO. 2 GENERATORS FUEL DRAIN LINES ARE PLUGGED AND FULL OF FUEL (SOLAS 74U II-2/2). CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 26 November 2001
Resolved 7 December 2001
Fire Fighting
Issued 15 November 2001
Resolved
MISSING ALL BUT ONE FIRE HOSE IN THE ENGINE ROOM AND MISSING FOUR HOSES ON DECK (SOLAS 74U II-2/32). REPLACE ALL HOSES. COMPLETE TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE FROM PORT.
Condition: Unknown
Due 26 November 2001
Resolved 3 December 2001
Engineering
Issued 15 November 2001
Resolved
NO. 1 AND NO. 2 GENERATORS MISSING VARIOUS GAUGES (SOLAS 74A REG. I/11).
Condition: Unknown
Due 26 November 2001
Resolved 3 December 2001
Engineering
Issued 15 November 2001
Resolved
NO. 1 AND NO. 2 HIGH PRESSURE LINES ON MAIN ENGINE WELDED AND REPAIRED_x001C_ (SOLAS 74A REG. I/11). REPAIR TO THE SATISFACTION OF CALSS PRIOR TO DEPARTURE FROM PORT.
Condition: Unknown
Due 26 November 2001
Resolved 7 December 2001
Lifesaving
Issued 15 November 2001
Resolved
EXCESSIVE FUEL AND OIL IN UPPER AND LOWER ENGINE ROOM BILGES (SOLAS 74U II-2/2). CORRECT TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE FROM PORT.
Condition: Unknown
Due 26 November 2001
Resolved 7 December 2001
Construction/Loadline
Issued 15 November 2001
Resolved
DECK PLATES IN ENGINE ROOM ARE NOT ANCHORED DOWN OR THE CORRECT SIZE FOR THEIR PLACEMENT (ILLC 66/ANNEX I/15). REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 November 2001
Resolved 7 December 2001
Deck/Cargo
Issued 15 November 2001
Resolved
NO. 5 CRANE STARBOARD CARGO WINCH BRAKE CYLINDER LEAKING EXCESSIVELY (SOLAS74A REG. I/11). REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE FROMPORT.
Condition: Unknown
Due 26 November 2001
Resolved 3 December 2001
Engineering
Issued 15 November 2001
Resolved
ALL MAIN ENGINE HIGH PRESSURE FUEL INJECTOR LINES MISSING THE UPPER AND LOWER SLEEVES FOR DOUBLE-JACKETING THE FUEL PIPES (SOLAS 74A II-2/15.2.9). REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE FROM PORT.
Condition: Unknown
Due 26 November 2001
Resolved 7 December 2001
Lifesaving
Issued 15 November 2001
Resolved
EPIRB HAS EXPIRED HYDROSTATIC RELEASE (SOLAS 74A IV/7.1.6.4). CORRECT TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE FROM PORT.
Condition: Unknown
Due 26 November 2001
Resolved 3 December 2001
Deck/Cargo
Issued 15 November 2001
Resolved
NO. 1 MAIN AIR COMPRESSOR HAS CRACKED MAIN CRANKSHAFT (SOLAS 74A REG. I/11). REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE.
Condition: Unknown
Due 26 November 2001
Resolved 3 December 2001
Engineering
Issued 15 November 2001
Resolved
FRESH WATER COOLER FOR GENERATOR'S SALT WATER SUPPLY LINE PINHOLED AND LEAKING (SOLAS 74A REG. I/11). REPAIR TO THE SATISFACTION OF CLASS PRIOR TODEPARTURE FROM PORT.
Condition: Unknown
Due 26 November 2001
Resolved 3 December 2001
Fire Fighting
Issued 15 November 2001
Resolved
EMERGENCY FIRE PUMP HAS EXHAUST LEAKING INTO STEERING COMPARTMENT (SOLAS 74A II-2/21). REPAIR EXHAUST LEAK TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE FROM PORT.
Condition: Unknown
Due 26 November 2001
Resolved 3 December 2001
Engineering
Issued 15 November 2001
Resolved
MISSING VARIOUS MACHINERY GUARDS THROUGHOUT ENGINE ROOM (SOLAS 74A REG. I/11). COMPLETE BY NEXT U.S. PORT.
Condition: Unknown
Due 26 November 2001
Resolved 7 December 2001
Deck/Cargo
Issued 15 November 2001
Resolved
HYDRAULIC LINES ON NO. 2 AND NO. 3 CARGO HOLD PORT SIDE LEAKING (SOLAS 74A REG. I/11). REPAIR PRIOR TO NEXT U.S PORT.
Condition: Unknown
Due 26 November 2001
Resolved 3 December 2001
Lifesaving
Issued 15 November 2001
Resolved
COMPLETE AN EXTERNAL AUDIT OF THE VESSEL'S SAFETY MANAGEMENT SYSTEM (ISM CODE 10.2). TO BE COMPLETED BY A RECOGNIZED ORGANIZATION AUTHORIZED TO ACT ON BEHALF OF THE FLAG STATE PRIOR TO DEPARTURE FROM PORT.
Condition: Unknown
Due 26 November 2001
Resolved 3 December 2001