MAURY USCG vessel records Sign in
← All vessels

CLOUD IX

CLOUD IX is a 1994 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1994, most recently in March 2026, along with 54 deficiencies.

Records from 1994 to 2026. Most recent: inspection, 5 March 2026.

Built
1994
Last inspected
5 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCO5488
409723
Flag
UNITED STATES
—
Maury page id
psix-409723

Inspections, by type

…with no type recorded20
Years with a record 27 calendar years (1994–2026)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it3 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SILVER STREAK Passenger (Uninspected) · MISLE 372201 · 14 January 2006 · activity 2574086

Inspection history · 61

5 March 2026 Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8320526
12 February 2025 COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8078922
12 July 2024 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7960019
5 March 2024 Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7874187
10 January 2024 Deadweight Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7852954
7 March 2023 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7646654
1 March 2022 Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7403557
16 February 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7400313
30 March 2021 Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7170792
3 March 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7149242
24 March 2020 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6932053
3 March 2020 Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6920793
1 May 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6673939
1 April 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6653981
27 March 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6650914
21 March 2018 Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6376128
20 September 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6272024
2 September 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6275767
18 August 2017 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6255682
30 March 2017 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6118009
10 June 2016 Hull Examination · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5934330
6 September 2011 DAPI Audit · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4137526
9 October 2008 Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3341586
26 September 2007 Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3066952
26 July 2006 Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2725682
14 January 2006 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2574086
27 August 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2480492
14 July 2005 Hull Examination · COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2426463
23 April 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2465259
15 April 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2377654
28 September 2004 Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2207956
24 August 2004 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2195960
22 August 2004 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2195973
6 July 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2126276
10 March 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2025925
16 October 2003 Hull Examination · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1930787
5 March 2003 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1759826
24 June 2002 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1636515
5 June 2002 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1623890
19 July 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1070002
20 June 2001 Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1362350
6 September 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 822192
17 July 2000 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361592
6 July 1999 Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365286
16 December 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 808650
12 August 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1131649
10 July 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 212037
10 July 1998 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1440021
11 April 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 88510
11 April 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 227122
25 July 1997 Hull Examination · COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368325
24 November 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 134887
27 August 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1089301
9 August 1996 Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357688
10 July 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 120877
6 March 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1452124
8 February 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371287
9 August 1995 MARPOL Annex V Examination · Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355404
12 May 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 102047
9 August 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353630
15 July 1994 Plan Review "T" Boat · COI Inspection · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1377234

Deficiency record · 54

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2026 Resolved
A suitable metal marine type strainer must be fitted in the fuel supply line. A drip pan fitted with a flame screen must be installed under gasoline strainers. Fuel filters and strainers bowls must be highly resistant to shattering. Vessel Racor fuel filters corroded and missing drip pan bowls. Provide new approved fuel filters. 46 CFR 182.455(b)(6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2026
Resolved 3 April 2026
Resolution: New fuel filters provided
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 March 2023 Resolved
The minimum number of portable fire extinguishers required on a vessel must not be fewer than the minimum number required by Table 181.500(b). Vessel needs an additional 2-A rated portable fire extinguisher for the Accommodation space. 46CFR181.500(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2023
Resolved 22 March 2023
Resolution: New portable extinguisher provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 March 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. The vessel does not have an all-round white light. Place an all-around white light on the vessel. 46CFR183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2023
Resolved 24 March 2023
Resolution: New all around light installed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 March 2022 Resolved
Each survival craft required by a vessel must meet one of the following: For a life float - approved under approval series 160.027 or other standard specified. Net in life float was broken in several areas. Repair net. 46 CFR 180.200 (a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
Resolution: Net repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 1 March 2022 Resolved
An embarkation ladder, approved IAW 160.017 in subchapter Q of this chapter, or other standard specified by the Commandant. Embarkation ladder bolt holes are worn. Repair holes. 46 CFR 180.50 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 March 2022
Resolution: Welds completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 March 2022 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Extra child size life jackets stowage location was not marked. Label stowage area. 46 CFR 180.78
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2022
Resolution: Stowage location marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 March 2022 Resolved
Exhaust blower switches must be located outside of any space required to be ventilated by this section, and must be of type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. Exhaust blower switches were not interlocked accordingly. Interlock exhaust blower switches IAW this subpart. 46 CFR 182.460(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2022
Resolution: Interlock installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 March 2022 Resolved
The materials and construction of fuel lines, including pipe, tube, and hose, must meet the requirements of this paragraph. Discovered cracked fuel hose on starboard engine. Replace cracked hose. 46 CFR 182.455(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2022
Resolution: Fuel lines replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 March 2022 Resolved
Shutoff valves so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line. Shut off valves missing for the engine connection. Install shutoff valves for the engine connection. 46 CFR 182.455(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
Resolution: No servicing accessories on vessel as stated in 182.455(b)(4). Removed deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 March 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Hydraulic hose mounted is rusted through. Restore mount. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2022
Resolution: New hydraulic line installed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 March 2022 Resolved
At each inspection, the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Discovered severe pitting on steering connected rod. Replace rod. 46 CFR 176.814
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
Resolution: Rod replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 March 2022 Resolved
Battery installations must be mounted to protect against shifting of the vessel and free from exposure to water splash/spray. Battery covers were loose. Secure covers. 46 CFR 183.350(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
Resolution: Covers secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 March 2022 Resolved
Each ship transporting more that six passengers for hire equipped with a radiotelephone station must carry a radio operator who: holds a marine radio operator permit or higher class license. Master did not have marine radio operator permit. Provide proof of marine radio operator permit. 47 CFR 80.158 (e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 March 2022
Resolution: MROP provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 March 2022 Resolved
A drydock exam shall include inspection of hull plating from interior and exterior of vessel. Could not examine the internal hull plate where fuel tank is located. Make fuel tank space ready for inspection. 46 CFR 176.610
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 March 2022
Resolution: Tank space made ready for inspection. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
Provide Letter of Regulatory Compliance (LORC) for Reliable Drug Testing Services Consortium.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
Update EAP Information to reflect current changes to DAPI program (i.e., Provide EAP information posted in vessel common space; Identify SAP and update EAP information with contact information; Hot-line information, etc).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
Provide the DAPI covered employees list for BWR vessels. Confirm all employees have record of preemployment test or subject to random since COVID-19 shutdown.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel (continued on second page).Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2021 Resolved
Confirm Blue Water Rafting's policy regarding employment for mariner's who have tested positive on any of the five types of DOT chemical tests and the MRO return to work process.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 6 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 March 2021 Resolved
Gages to indicate lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. The port/stbd engine oil pressure gage was not operable during inspection. Provide operable oil pressure gage at operating station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 5 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2021 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Outboard battery was found to be sitting in approximately 5-6 inches of standing water. Remove water and dry out battery container.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 3 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 March 2021 Resolved
Hydrostatic release for EPIRB was expired. Install new hydrostatic release to ensure installment is set to automatically float free and activate in accordance with regulations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 3 March 2021
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 3 March 2021 Resolved
MMSI was not operable on VHF radio at time of inspection. Ensure MMSI # is properly entered into VHF radio for emergency use of the MOB/Distress button.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 3 March 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 3 March 2020 Resolved
Non-return devices on port and stbd scuppers were cracked. Renew in accordance with 46 CFR 176.802.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 9 March 2020
Resolution: Non-return devices renewed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 March 2020 Resolved
Ventilation duct under console was deteriorated. Renew in accordance with 46 CFR 176.816.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 9 March 2020
Resolution: Duct renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 March 2020 Resolved
Port tachometer was inoperative. Repair in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2020
Resolved 9 March 2020
Resolution: Tachometer repaired.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 27 March 2019 Resolved
Cracks were noted at center console running outboard, stbd approx 12"/port approx 6". Repair in accordance with 46 CFR 176.802.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2019
Resolved 29 March 2019
Resolution: Cracks repaired.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 March 2019 Resolved
VHF DSC function was not programmed. Prove DSC capability in accordance with 46 CFR 184.502.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2019
Resolved 30 April 2019
Resolution: VHF DSC radio programmed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 March 2019 Resolved
Hull inspection plates were not removed for inspection. Remove plates in accordance with 46 CFR 176.802.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2019
Resolved 29 March 2019
Resolution: Hull inspection plates were removed for inspection.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 30 March 2017 Resolved
Replace mounting bracket.
Due 17 April 2017
Resolved 31 March 2017
Resolution: Mounting bracket was replaced.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 July 2005 Resolved
Provide 18 adult PFD's
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2005
Resolved 14 July 2005
Lifesaving › Lifebuoys › Serviceable
Issued 14 July 2005 Resolved
Provide one 24" life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2005
Resolved 14 July 2005
Lifesaving › Buoyant Apparatus › Serviceable
Issued 14 July 2005 Resolved
Repair torn area on buoyant apparatus
Due 14 August 2005
Resolved 8 August 2005
Electrical › Electrical Distribution System (service)
Issued 5 June 2002 Resolved
Remove or properly repair dead end wires located at operating station IAW 46CFR183.340. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 19 June 2002
Resolved 24 June 2002
Construction/Loadline › Hull › Hull Plating
Issued 5 June 2002 Resolved
Provide plans for repair to stbd bow fracture IAW 46CFR176.700.
Condition: Unknown
Due 19 June 2002
Resolved 5 June 2002
Resolution: Recieved plans for repair. Conducted SAT repairs at A Plus Welding Services INC. Witnessed repair procedures IAW inspection note #37.
Engineering
Issued 20 June 2001 Resolved
Remote fuel shutoff not working properly. Prove proper operation or shield valve IAW 46CFR182.455(b)(4) NLT 20JUL01.
Condition: Unknown
Due 19 July 2001
Resolved 19 July 2001
Navigation
Issued 20 June 2001 Resolved
Hydraulic steering hose fitting rusted and damaged the hose. Renew as appropriate with hose/fitting assemblies that meet SAE J-1942 NLT 20JUL01._x001C__x001C_ _x001C_
Condition: Unknown
Due 19 July 2001
Resolved 19 July 2001
Engineering
Issued 17 July 2000 Resolved
Prove proper operation of starboard engine temperature gauge IAW 46CFR176.804 NLT 17 AUG 00.
Condition: Unknown
Due 19 August 2000
Resolved 19 August 2000
Lifesaving
Issued 17 July 2000 Resolved
Prove survival craft are in a float free arrangement NLT 17AUG00, IAW 46CFR180.130(a)(2).
Condition: Unknown
Due 19 August 2000
Resolved 19 August 2000
Construction/Loadline
Issued 17 July 2000 Resolved
Conduct satisfactory alternate chamber pressure test in the presence of a Marine Inspector not later than 17AUG00. Vessel reduced to 15 passengers until in compliance. 46CFR176.800 and MSO inspection note 22.
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Engineering
Issued 17 July 2000 Resolved
Prove proper operation of fuel gauge IAW 46CFR176.804 NLT 17AUG00.
Condition: Unknown
Due 19 August 2000
Resolved 19 August 2000
Lifesaving
Issued 17 July 2000 Resolved
Repair or renew Ring Buoy NLT 24JUL00 IAW 46CFR180.70 and 160.050.
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Fire Fighting
Issued 6 July 1999 Resolved
Provide proof of current hydro test on Fixed CO2 bottle.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Navigation
Issued 6 July 1999 Resolved
Provide proof of operational mast head light. Vessel is restricted to daylight operations until in compliance.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Lifesaving
Issued 9 August 1996 Resolved
Renew EPIRB battery.
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Documentation
Issued 8 February 1996 Resolved
Provide evidence of compliance with chemical testing regulations to include: a)60 minutes supervisor training, b)Employee assistance program and c) employee acknowledgements.
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Construction/Loadline
Issued 9 August 1994 Resolved
MAKE VESSEL AVAILABLE FOR INFLATION TESTS PER LOCAL POLICY (CIDNOTE 22).
Condition: Unknown
Due 9 August 1994
Resolved 9 August 1994
Lifesaving
Issued 9 August 1994 Resolved
MARK THE LIFEFLOAT WITH THE TOTAL NUMBER OF PERSONS (15).
Condition: Unknown
Due 9 August 1994
Resolved 9 August 1994
Lifesaving
Issued 9 August 1994 Resolved
PROVIDE WATERLIGHT FOR RING BUOY. VESSEL IS RESTRICTED TO DAYLIGHT_x001C_ OPERATIONS UNTIL COMPLETE.
Condition: Unknown
Due 9 August 1994
Resolved 9 August 1994
Documentation
Issued 9 August 1994 Resolved
PROVIDE OIL DISCHARGE PLACARD.
Condition: Unknown
Due 9 August 1994
Resolved 9 August 1994
Navigation
Issued 9 August 1994 Resolved
PROVIDE CHART FOR THE KAUAI OPERATING AREA. VESSEL IS RESTRICTED FROM OPERATING IN KAUAI UNTIL COMPLETED.
Condition: Unknown
Due 9 August 1994
Resolved 9 August 1994
Navigation
Issued 15 July 1994 Resolved
PROVIDE COPIES OF ALL REQUIRED CHARTS AND PUBLICATIONS NECESSARY FOR SAFE VESSEL OPERATION.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Documentation
Issued 15 July 1994 Resolved
PROVIDE WRITTEN PROOF OF VESSEL'S STABILITY INCLUDING A DIAGRAM SHOWING FIXED SEATING ARRANGEMENT FOR PASSENGERS AT 18 INCHES PER PERSON.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Lifesaving
Issued 15 July 1994 Resolved
PROVE VESSEL IS FULLY OUTFITTED AND OPERATIONAL TO MARINE INSPECTOR IN AREAOF OPERATION.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.