MAURY USCG vessel records Sign in
← All vessels

THE DRIFT OUT

THE DRIFT OUT is a 1994 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 1994, most recently in November 2025, along with 67 deficiencies.

Records from 1994 to 2025. Most recent: inspection, 10 November 2025.

Built
1994
Last inspected
10 November 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ4266
409748
Flag
UNITED STATES
—
Maury page id
psix-409748

Inspections, by type

…with no type recorded4
Years with a record 30 calendar years (1994–2025)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 50

10 November 2025 Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8266891
9 May 2025 Simplified Stability Test · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8131944
13 March 2024 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7878476
27 November 2023 Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7830095
7 March 2023 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7647182
7 July 2022 DAPI Audit · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7499775
6 July 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7509944
18 June 2022 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7485884
11 February 2022 COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7394996
25 January 2022 Plan Review "T" Boat
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7385279
16 August 2021 Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7288576
15 June 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7226143
15 July 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7007280
21 February 2019 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6630611
11 February 2019 Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6623920
26 February 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6361891
7 February 2017 Deficiency Check · Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6083830
2 February 2017 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6081782
21 November 2016 Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 6046055
26 July 2016 Construction Oversight · Simplified Stability Test
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5953825
27 October 2015 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5750846
1 October 2014 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5001994
16 September 2011 Administrative Inspection · Drydock Exam · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4154629
6 January 2010 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3659513
4 January 2010 Administrative Inspection · Hull Examination · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3685278
6 May 2009 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3468913
7 May 2008 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3200984
6 May 2008 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3199367
14 June 2007 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2958412
20 March 2007 Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2891489
26 September 2006 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2787213
22 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2655901
10 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2644845
20 May 2005 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2365641
10 May 2005 COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2354144
6 May 2004 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2060433
12 May 2003 Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1791660
4 June 2002 Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1627352
3 April 2002 Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1600579
4 June 2001 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1423585
30 May 2001 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1441849
15 June 2000 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 819459
18 May 2000 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1439035
4 May 1999 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 797970
12 May 1998 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1124968
30 May 1997 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1111188
10 March 1997 Deficiency Check · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1099619
25 June 1996 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1084828
24 February 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1160666
23 June 1994 Initial Construction-Excluding Oversight · Hull Examination · Plan Review "T" Boat · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1178532

Deficiency record · 67

10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 July 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. Vessel did not have a current chart on the vessel.
Action required: 10 - Deficiency Rectified
Due 7 July 2022
Resolved 7 July 2022
Resolution: Vessel owner purchased and placed in service a current chart.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 July 2020 Resolved
Vessel must carry adequate and up to date navigation publications. Vessel did not have current coast pilot, light list, and rules of the road onboard. Provide evidence of current publications onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 23 July 2020
Resolution: received pictures, all sat
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 July 2020 Resolved
Vessel must carry onboard an approved first aid kit with current equipment. Vessel had expired ammonia inhalants, aspirin, and burn gel. Provide evidence of current equipment onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 21 July 2020
Resolution: received pictures of new kit, all sat
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 16 July 2020 Resolved
Vessel must have onboard or readily available, the Drug Testing consortium policy, EAP inofrmation, hotline telephone numbers, and supervisor training for the captain. Provide evidence of policy information and supervisor training onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 28 July 2020
Resolution: Received pictures of all mentioned issues with DAPI, all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 March 2019 Resolved
Replace retro-reflective material on 7 lifejackets and 3 child-size lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2019
Resolution: Cleared by [name withheld]
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 6 March 2019 Resolved
Post Stability Letter at operating station.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2019
Resolution: Cleared by [name withheld]
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 March 2019 Resolved
Provide current/corrected charts for area of operation and coast pilot.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 7 March 2019
Resolution: Cleared by [name withheld]
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 March 2017 Resolved
PFD's retro tape worn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 23 March 2017
Resolution: Retro tape added to PFD's.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 March 2017 Resolved
Water light on ring buoy missing battery.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 23 March 2017
Resolution: Battery installed and tested sat.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 March 2017 Resolved
Portable fire extinguishers required to have approved mounting brackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 23 March 2017
Resolution: Brackets purchased and installed.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 14 March 2017 Resolved
Provide proof of initial 60 minutes of EAP training for supervisory personnel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 23 March 2017
Resolution: Supervisory training completed.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 14 March 2017 Resolved
Post emergency procedures.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 23 March 2017
Resolution: Emergency instructions posted.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 14 March 2017 Resolved
Post EAP hotline phone number.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 23 March 2017
Resolution: EAP phone number posted.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 14 March 2017 Resolved
Post drug zero tolerance policy.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 23 March 2017
Resolution: EAP policy posted.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 March 2017 Resolved
Provide current or currently corrected charts for area of operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 23 March 2017
Resolution: Updated charts provided.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 1 October 2014 Resolved
Install flame scree in fuel tank vent IAW 46 CFR 182.450.
Action required: 705 - Other - as specified
Due 1 November 2014
Resolved 9 October 2014
Resolution: Received email pictures of new tank vent and flame scree - administratively cleared.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 October 2014 Resolved
Renew ring bouy line with bouyant, UV resistant line IAW 46 CFR 180.70(c)(1).
Action required: 705 - Other - as specified
Due 1 November 2014
Resolved 9 October 2014
Resolution: Received email photo of new line installed. Administratively cleared.
Navigation › Piloting/Steering › Marine Charts
Issued 16 September 2011 Resolved
Provide proper up to date charts onboard specific for route intended and large enough scale to make safe operation IAW 46 CFR 420 (a) (1), w/in 30 days of the inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 October 2011
Resolved 17 September 2012
Resolution: Updated chart onboard.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 16 September 2011 Resolved
Provide a proper emergency broadcast placard next to the VHF radio and make the placard specific to the vessels use; with 1 week of this inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 September 2011
Resolved 22 September 2011
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 September 2011 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 22 September 2011
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 16 September 2011 Resolved
Provide an up to date MIS report for the year 2010 IAW the annual drug and alcohol program, 46 CFR 16.500.
Action required: 705 - Other - as specified
Resolved 22 September 2011
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 January 2010 Resolved
Properly provide 4 additional Adult Type I PFD's, with the vessel name on the PFD's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 July 2010
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 January 2010 Resolved
Properly provide a Coast Guard approved (46 CFR 161.010) self activating water light wtih a 3 foot lanyard prior to to conducting night time operations.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 6 August 2010
Documentation › Markings/Placards › Lifejacket Placard
Issued 4 January 2010 Resolved
Provide proper donning placards for PFD's and post in conspicuous place that are regularly accessible and visible to the crew and passengers, IAW 46 CFR 185.516.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 July 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 May 2009 Resolved
Renew rope lifelines (rail courses).
Action required: 705 - Other - as specified
Due 13 June 2009
Resolved 3 June 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 May 2009 Resolved
Prove proper operation of nav lights. Vsl restricted to daylight operations until satisfied.
Action required: 705 - Other - as specified
Due 13 June 2009
Resolved 3 June 2009
Electrical › Lighting (service) › Conductor
Issued 6 May 2009 Resolved
Make all electrical connections permanent.
Action required: 705 - Other - as specified
Due 13 June 2009
Resolved 3 June 2009
Engineering › Gasoline Engine (propulsion) › Combustion Chamber (2 stroke)
Issued 6 May 2009 Resolved
Prove proper operation of water temp gauge.
Action required: 705 - Other - as specified
Due 13 June 2009
Resolved 3 June 2009
Resolution: Water temp gauge is not available this make and model engine.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 May 2008 Resolved
Provide serviceable B-I portable fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2008
Resolved 7 May 2008
Lifesaving › Lifebuoys › Serviceable
Issued 6 May 2008 Resolved
Provide serviceable lifebuoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2008
Resolved 7 May 2008
Engineering › Steering Gear System › Power Unit
Issued 6 May 2008 Resolved
Provide auxiliary steering system.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 7 May 2008
Construction/Loadline › Hull › Longitudinal Frame
Issued 22 March 2007 Resolved
Make repairs to longitudinal frames in way of port and starboard pontoons, aft, where fractures have developed. Provide office with repair proposal for review.
Condition: Unknown
Due 15 June 2007
Resolved 14 June 2007
Resolution: Cleared.
Construction/Loadline › Hull › Hull Plating
Issued 22 March 2007 Resolved
Make compartment #3, port pontoon, and #4 starboard pontoon, available for inspection. (O/O could not open PVC plug to each space at time of this visit.)
Condition: Unknown
Due 15 June 2007
Resolved 14 June 2007
Resolution: Cleared.
Construction/Loadline › Hull › Hull Plating
Issued 22 March 2007 Resolved
Make repair to W/T Compartment #4, center pontoon, where small undercut or pinhole exist from previous repair. (Provide this office with repair proposal for review.)
Condition: Unknown
Due 15 June 2007
Resolved 14 June 2007
Resolution: Cleared.
Construction/Loadline › Hull › Hull Plating
Issued 22 March 2007 Resolved
Make center pontoon, W/T compartments #4 & #5, Port and Starboard pontoon W/T compartments #6 & #7, available for Audio Gauge, to be witnessed by inspectors from this office.
Condition: Improper/Lack of Maintenance
Due 15 June 2007
Resolved 14 June 2007
Resolution: Cleared.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 10 May 2006 Resolved
Vessels fuel tank is to be properly grounded IAW 46 CFR 182.440(b)(4).
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 22 May 2006
Resolution: Tank grounded
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 May 2006 Resolved
Vessel is to provided a 3' lanyard with clip for the ring bouy waterlight IAW 46 CFR 180.70(d)(2).
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 22 May 2006
Resolution: New lanyard installed
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 May 2006 Resolved
Vessel is to install a means to prevent passengers from accessing the forward portion of the vessel while underway due to the fact that the forward rails are incapable of handling the required 200 lb point load test.
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 22 May 2006
Resolution: Railing installed
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 May 2005 Resolved
Issued CG-835 to replace expired items in first aid kit.
Due 24 May 2005
Resolved 20 May 2005
Resolution: Verified that the contents of the first aid kit are within the expiration dates.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 10 May 2005 Resolved
Issued CG-835 to replace fire extinguisher bracket
Due 24 May 2005
Resolved 20 May 2005
Resolution: Verified the fire extinguisher mount has been replaced with the proper bracket and in good working order.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 May 2005 Resolved
Issued CG-835 to repair navigation lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2005
Engineering › Fuel Oil Service System
Issued 6 May 2004 Resolved
Issued CG-835 to double clamp fuel hose connections on the fuel filter. LEGACY COMPONENT DESC: Filter
Condition: Placed in Improper Service
Due 17 May 2004
Resolved 6 May 2004
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 6 May 2004 Resolved
Issued CG-835 to post lifejacket donning procedures for the vest type lifejackets.
Condition: Unknown
Due 17 May 2004
Resolved 7 May 2004
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 6 May 2004 Resolved
Issued CG-835 to replace retro-flective tape on the 4 adult & 1 child lifejackets designated by the inspector. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Damaged By Earlier Event
Due 17 May 2004
Resolved 7 May 2004
Resolution: Corrected.
Navigation › Piloting/Steering
Issued 6 May 2004 Resolved
Issued CG-835 to provide a chart for the route transited. LEGACY COMPONENT DESC: Marine Charts
Condition: Unknown
Due 17 May 2004
Resolved 7 May 2004
Resolution: Corrected.
Personnel › Manning/Qualifications
Issued 6 May 2004 Resolved
Issued CG-835 to provide proof of first aid. LEGACY COMPONENT DESC: First Aid Certified Personnel
Condition: Unknown
Due 17 May 2004
Resolved 15 May 2004
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 12 May 2003 Resolved
Issued CG-835 to make electrical connections permanent on wiring coming from the batteries. Connections were twisted together and wrapped in black electrical tape. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Due 8 June 2003
Resolved 12 May 2003
Resolution: Corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 12 May 2003 Resolved
Issued CG-835 to replace fire extinguisher bracket. The bracket was so corroded that the bottom was completely missing. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Unknown
Due 8 June 2003
Resolved 3 June 2003
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 May 2003 Resolved
Issued CG-835 to label location of child lifejackets. The storage area was not designated. All storage areas were just marked life jackets. Did not require the owner to mark the other locations "adult" as long as the child storage was properly marked. LEGACY COMPONENT DESC: Storage
Condition: Unknown
Due 8 June 2003
Resolved 12 May 2003
Resolution: Corrected.
Accommodation/Occupational Safety › Medical/First Aid
Issued 12 May 2003 Resolved
Issued CG-835 to provide CG approved first aid kit. The kit was a normal recreational kit and did not meet the requirements of 46 CFR 160.041-4. LEGACY COMPONENT DESC: Kit
Condition: Unknown
Due 8 June 2003
Resolved 3 June 2003
Resolution: Corrected.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 4 June 2002 Resolved
CLEAN TOILET COMPARTMENT
Condition: Improper/Lack of Maintenance
Due 18 June 2002
Resolved 17 June 2002
Documentation › Logs/Records
Issued 4 June 2002 Resolved
Provide passenger count plan
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2002
Resolved 5 June 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 4 June 2002 Resolved
Provide CG approved or equivelant first aid kit LEGACY COMPONENT DESC: Medicine Chest
Due 18 June 2002
Resolved 17 June 2002
Engineering › Gasoline Engine (propulsion)
Issued 4 June 2002 Resolved
Permanent mount outboard cable
Condition: Placed in Improper Service
Due 18 June 2002
Resolved 17 June 2002
Construction/Loadline › Hull
Issued 3 April 2002 Resolved
Vessels center hull and inboard plating of port and starboard hulls how signs of electrolysis. Idications of dissimilar metals in the center hull. Issued CG-835 to identify root problem, submit repair proposal and complete permanent repairs NLT 30SEP02. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 6 May 2004
Resolution: Corrected.
Navigation
Issued 30 May 2001 Resolved
MAKE PROPER REPAIRS TO STARBOARD RUNNING LIGHT AND MASTHEAD LIGHT.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Lifesaving
Issued 30 May 2001 Resolved
PLACE NAME OF VESSEL ON RING LIFE BUOY.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Documentation
Issued 18 May 2000 Resolved
Post Stability ltr, Emergency instructions, COI and lifejacket instructions
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Lifesaving
Issued 18 May 2000 Resolved
Provide Documentation that 50 percent of the crew has been trained in CPR/First Aid.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Documentation
Issued 30 May 1997 Resolved
PROVIDE STABILITY LETTER.
Condition: Unknown
Due 30 May 1997
Resolved 2 June 1997
Documentation
Issued 30 May 1997 Resolved
PROVIDE PROOF OF DRUG TESTING FOR 50% OF CREW._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 May 1997
Resolved 2 June 1997
Documentation
Issued 30 May 1997 Resolved
PROVIDE INFORMATION ON DRUG TESTING PROGRAM.
Condition: Unknown
Due 30 May 1997
Resolved 2 June 1997
Lifesaving
Issued 24 February 1995 Resolved
Post Stability Letter, Certificate of Inspection, Emergency Check-off list and Lifejacket donning proceedures placard.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Lifesaving
Issued 23 June 1994 Resolved
Provide 6 additional adult pfd's. Restricted to 22 passengers until completed.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Lifesaving
Issued 23 June 1994 Resolved
Provide retrotape for ringbuoy.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Lifesaving
Issued 23 June 1994 Resolved
Mark life presever lockers with number stowed inside and 1" letters "LIFE PRESERVERS".
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994
Engineering
Issued 23 June 1994 Resolved
Mark emergency fuel shutoff valve in 1" letters.
Condition: Unknown
Due 23 June 1994
Resolved 23 June 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.