← All vessels
MF 10
MF 10 is a 1971 tank barge. The Coast Guard has recorded 42 inspections since 1981, most recently in May 1998, along with 12 deficiencies.
Records from 1981 to 1998. Most recent: inspection, 5 May 1998.
- Built
- 1971
- Last inspected
- 5 May 1998
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
683692
40975
Flag
UNITED STATES
—
Maury page id
psix-40975
Inspections, by type
…with no type recorded22
Years with a record
18 calendar years (1981–1998)
The 42 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it601 - Simplified, Net Ton
601 - Simplified, Gross Ton
601 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 42
5 May 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125080
19 December 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 763190
28 November 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 209834
21 March 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 773381
20 March 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1371712
21 June 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1081648
15 February 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1439701
19 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 439817
13 April 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1427034
17 February 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1426867
25 February 1993
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1148727
18 February 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412474
5 November 1992
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 948051
20 February 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1258689
2 July 1991
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1245023
12 April 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 900285
14 March 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 917520
7 May 1990
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 497975
23 February 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 929390
1 June 1989
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 480598
13 April 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1212054
3 September 1988
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 457536
26 February 1988
Hull Examination · COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1026260
3 December 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1003504
17 September 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1008385
25 August 1987
Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1338450
18 June 1987
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 528242
18 December 1986
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 515532
12 November 1986
Deficiency Check · COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1015829
12 November 1986
Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1326469
21 October 1986
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1318071
19 May 1986
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 997279
8 April 1986
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 453753
4 June 1985
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 539700
16 November 1984
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 482178
15 November 1984
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 506792
13 November 1984
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1283570
13 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971742
8 February 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971514
15 December 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278866
11 January 1982
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1279362
3 April 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279348
Deficiency record · 12
Deck/Cargo
Issued 20 March 1997
Resolved
PROVE PROPER OPERATION OF PUMP ENGINE AND REMOTE SHUTDOWN IN THE PRESENCE OF CG MARINE INSPECTOR.
Deck/Cargo
Issued 25 August 1987
Resolved
THERE ARE NO "DANGER KEEP OUT" SIGNS ON THE CARGO HATCHES. PROVIDE THESE SIGNS AT THE PROPER LOCATIONS.
Deck/Cargo
Issued 25 August 1987
Resolved
THREADS ON TOGGLE BOLTS ON THE HATCH COVERS WERE PLUGGED, PREVENTING THE HATCHES FROM BEING PROPERLY TIGHTENED. CLEAN TOGGLE BOLTS PRIOR TO LOADING THE NEXT CARGO.
Deck/Cargo
Issued 25 August 1987
Resolved
CARGO PUMP DRIVE ENGINE FUEL FILTER HAS A PETCOCK IN THE BOTTOM. REPLACE THE PETCOCK WITH A PLUG OR POSITIVE ACTION VALVE OR REPLACE THE FILTER HOUSING WITH ONE SO EQUIPPED.
Construction/Loadline
Issued 25 August 1987
Resolved
ALL DRAFT MARKS ILLEGIBLE. REPAINT DRAFT MARKS.
Deck/Cargo
Issued 25 August 1987
Resolved
REMOTE EMERGENCY SHUT DOWN SIGN ILLEGIBLE. RELETTER THE SIGN.
Construction/Loadline
Issued 25 August 1987
Resolved
4' OF WATER IN THE BOX STERN. HOLE AT THE 7'DRAFT IN PORT SIDE SHELL. 6" VERTICLE CRACK IN THE CORNER WRAPPER ON PORT STERN. MAKE PERMANENT REPAIRS AND PROVE THE SOUNDNESS OF THE COMPARTMENT TO THE SATISFACTION OF THE ATT- ENDING USCG MARINE INSPECTOR PRIOR TO LOADING THE NEXT CARGO.
Construction/Loadline
Issued 25 August 1987
Resolved
18" OF WATER IN #3S WING VOID, DETECTED THE SOUND OF LEAKING WATER. LOCATE THE SOURCE OF THE LEAK IN THE COMPARTMENT, MAKE PERMANENT REPAIRS, AND PROVE THE SOUNDNESS OF THE COMPARTMENT TO THE SATISFACTION OF THE ATTENDINGUSCG MARINE INSPECTOR PRIOR TO LOADING THE NEXT CARGO.
Deck/Cargo
Issued 19 May 1986
Resolved
TEST CARGO PIPING AT 1-1/2 TIMES MAWP AND PROVIDE RECORD OF THE TEST.
Construction/Loadline
Issued 19 May 1986
Resolved
HORIZONTAL PUNCTURE/SET-IN/CRACK ABOUT 24" LONG IN PORT BOW RAKE CORNER WRAPPER AT HEADLOG. CROP OUT DAMAGED AREA AND RENEW AS ORIGINAL.
Unknown
Issued 15 December 1983
Resolved
PERFORM THE ANNUAL TESTS AND INSPECTIONS REQUIRED BY 33 CFR 156.170.
Unknown
Issued 15 December 1983
Resolved
THE FOLLOWING DEFICIENCY IS FOR THE RGT 908, CG008052.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.