MAURY USCG vessel records Sign in
← All vessels

HOUSTON

HOUSTON is a 1985 freight ship. The Coast Guard has recorded 17 inspections since 1995, most recently in November 1999, along with 44 deficiencies — 4 with no resolution recorded — and 2 operational controls.

Records from 1995 to 1999. Most recent: inspection, 3 November 1999.

Built
1985
Last inspected
3 November 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8600492 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
409987
Flag
UKRAINE
—
Maury page id
psix-409987

Inspections, by type

…with no type recorded17
…past their stated due date4
Years with a record 5 calendar years (1995–1999)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8092 - Regulatory (Subpart C or D), Net Ton
15893 - Regulatory (Subpart C or D), Gross Ton
17850 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

3 November 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 434303
25 February 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 413059
22 June 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 404840
14 December 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 398507
12 December 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 398209
30 September 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 395951
23 September 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 395561
9 July 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 90692
31 October 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 645350
3 October 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 383329
25 September 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 191367
25 September 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 457720
25 September 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 755555
8 April 1995 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1420959
27 March 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 191369
27 March 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 376514
27 March 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 760010

Deficiency record · 44

Documentation
Issued 3 November 1999 No resolution recorded
Incomplete Pollution Placard in vicinity of Oily water seperator._x001C_
Condition: Unknown
Due 3 May 2000 — due date passed with no resolution recorded
Lifesaving
Issued 3 November 1999 No resolution recorded
Four rations in Port lifeboat, Fifteen rations in starboard lifeboat, vacuum seals are bad.
Condition: Unknown
Due 3 May 2000 — due date passed with no resolution recorded
Documentation
Issued 3 November 1999 No resolution recorded
Incomplete Pollution Placard in vicinity of Oily Water Seperator.
Condition: Unknown
Due 3 May 2000 — due date passed with no resolution recorded
Fire Fighting
Issued 3 November 1999 No resolution recorded
International Shore Connections need two washers per bolt, in accordance with Solas 74 CH II-2.
Condition: Unknown
Due 3 November 1999 — due date passed with no resolution recorded
Navigation
Issued 23 September 1996 Resolved
SECURELY MOUNT THE EMERGENCY RADIO BATTERIES TO PREVENT THEM FROM SHIFTING IN ROUGH WEATHER._x001C_ SEE SOLAS 74 AMENDED II-1/45.9.1
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Electrical
Issued 23 September 1996 Resolved
RENEW/REPAIR INOPERABLE EMERGENCY LIGHT LOCATED BENEATH THE LADDER STBD SIDE IN WAY OF THE STBD LIFEBOAT._x001C_ SEE SOLAS 74 AMENDED II-1/43.2.2
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Engineering
Issued 23 September 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING PIPE FOR THE STERN TUBE CYLINDER COOLING LOCATED IN THE ENGINE ROOM LOWER LEVEL AFT PORT SIDE OF THE SHAFT._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Accommodation/Occupational Safety
Issued 23 September 1996 Resolved
RENEW AS ORIGINAL, MISSING CLOSURE TO NATURAL VENTLATION LOCATED ON THE FOC'SLE._x001C_ SEE SOLAS 74 AMENDED II-2/48/16
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Engineering
Issued 23 September 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING SUPPLY PIPE FOR THE #3 MAIN GENERATOR LUBE OIL COOLER LOCATED IN THE GENERATOR ROOM AFT OF THE GENERATOR AT THE DECK PLATES._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Engineering
Issued 23 September 1996 Resolved
PROVE SATISFACTORY OPERATION OF THE SHIPS OILY WATER SEPERATING SYSTEM INCLUDING THE 15PPM ALARM AND AUTO STOPPING DEVICE._x001C_ SEE 33 C.F.R. 155.380(b)
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Navigation
Issued 23 September 1996 Resolved
CONDUCT SATISFACTORY STEERING GEAR TESTS.
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Lifesaving
Issued 23 September 1996 Resolved
CONDUCT A SATISFACTORY FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Engineering
Issued 23 September 1996 Resolved
RENEW AS ORIGINAL THE DETERIORATED SEA WATER COOLING SUPPLY PIPE FOR THE GYRO COMPASS COOLING UNIT._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Engineering
Issued 23 September 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING SUPPLY PIPES (3) LOCATED IN THE ENGINE ROOM #2 DECK FWD CENTERLINE. (RED PIPES)_x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Engineering
Issued 23 September 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING SUPPLY PIPE FOR THE AUX. ENGINE LOCATED IN THE ENGINE ROOM 2ND LEVEL STBD SIDE._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Engineering
Issued 23 September 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING SUPPLY PIPE FOR THE MAIN AIR COMPRESSORS LOCATED FWD OF THE AIR COMPRESSORS._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Lifesaving
Issued 23 September 1996 Resolved
RENEW MISSING SKATE ON PORT LIFEBOAT._x001C_ SEE SOLAS 74 AMENDED III/47.7.9
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 23 September 1996 Resolved
PROVIDE ONBOARD VESSEL, A TRAINING MANUAL FOR LIFESAVING APPLIANCES THAT COMPLIES WITH THE REQUIREMENTS OF SOLAS 74 AMENDED III/51_x001C_ SEE SOLAS 74 AMENDED III/18.2
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Fire Fighting
Issued 23 September 1996 Resolved
CLEAN ENGINE ROOM VENT LOCATED ON THE STARBOARD SIDE, DECK 3._x001C_ SEE SOLAS 74 (AMENDED) I/11(a)
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 23 September 1996 Resolved
RENEW/REPAIR THE TWO (2) BROKEN WINDOWS ON THE PORT LIFEBOAT._x001C_ SEE SOLAS 74 (AMENDED) III/19.2
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Construction/Loadline
Issued 23 September 1996 Resolved
RENEW ALL MISSING NON-RETURN CHECK VALVE BALLS FOR THE BALLAST TANK OVERFILLS/VENTS THROUGHOUT THE MAIN DECK._x001C_ SEE ICLL 66 REGULATION 19
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 23 September 1996 Resolved
PROVIDE FOR BOTH LIFEBOATS A BUOYANT LIFELINE BECKETED AROUNG THE OUTSIDE OF THE LIFEBOATS._x001C_ SEE SOLAS 60 III/11
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Documentation
Issued 23 September 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 23 September 1996 Resolved
Provide onboard vessel, instructions for the onboard maintenance of lifesaving appliances._x001C_ See Solas 74 Amended III/19.3/52
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Accommodation/Occupational Safety
Issued 23 September 1996 Resolved
RENEW MISSING CLOSURE TO NATURAL VENTILATION CLOSURE LOCATED ON THE MAIN DECK FWD BULKHEAD OF THE MAIN DECK HOUSE._x001C_ SEE SOLAS 74 AMENDED II-2/48/16
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Fire Fighting
Issued 23 September 1996 Resolved
RENEW AS ORIGINAL DETERIORATED FIREMAIN PIPING TO THE ENERGENCY FIRE PUMP LOCATED IN THE EMERGENCY FIRE PUMP COMPARTMENT BENEATH THE DECK PLATES._x001C_ SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Fire Fighting
Issued 23 September 1996 Resolved
SERVICE ALL FIRE MAIN HYDRANT VALVES TO PROVIDE SMOOTH OPERATION._x001C_ SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Fire Fighting
Issued 23 September 1996 Resolved
RENEW/REPAIR INOPERABLE FIRE MAIN HYDRANT VALVE LOCATED ON THE MAIN DECK PORT SIDE OF THE #2 CARGO HOLD._x001C_ SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Accommodation/Occupational Safety
Issued 23 September 1996 Resolved
RENEW MISSING GASKET TO THE VENTILATION CLOSURE LOCATED ON THE MAIN DECK FWD OF AFT PILOT HOUSE. (T-91)_x001C_ SEE SOLAS 74 AMENDED II-2/48/16
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Construction/Loadline
Issued 23 September 1996 Resolved
RENEW AS ORIGINAL DETERIORATED BALLAST PIPING LOCATED IN THE EMERGENCY FIREPUMP COMPARTMENT BENEATH THE DECK PLATES._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Construction/Loadline
Issued 23 September 1996 Resolved
RENEW MISSING GASKET TO THE WATERTIGHT DOOR LOCATED ON THE MAIN DECK PORT SIDE OF THE MAIN DECK HOUSE._x001C_ SEE SOLAS 74 AMENDED II-1/25-9.1
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Accommodation/Occupational Safety
Issued 23 September 1996 Resolved
RENEW/REPAIR INOPERABLE VENTILATION CLOSURES (7) LOCATED ON THE PORT SIDE MAIN DECK AFT._x001C_ SEE SOLAS 74 AMENDED II-2/48/16
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Accommodation/Occupational Safety
Issued 23 September 1996 Resolved
REMOVE ALL EXCESSIVE OIL AND OIL RESIDUE FROM THE FOLLOWING AREAS: (a) ALL CONTAINMENTS THROUGHOUT THE ENGINE ROOM, (b) THE MAIN GENERATOR, (c) THE BILGES IN THE GENERATOR ROOM, (d) THE FUEL OIL SEPERATOR ROOM.
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Engineering
Issued 23 September 1996 Resolved
RENEW AS ORIGINAL DETERIORATED FRESH WATER SERVICE PIPE LOCATED IN THE OVERHEAD OF THE AFT STBD CORNER OF THE SEPERATOR ROOM._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Construction/Loadline
Issued 23 September 1996 Resolved
RENEW MISSING GASKET TO THE WATERTIGHT DOOR LOCATED ON THE STBD SIDE OF THEMAIN DECK HOUSE ON THE MAIN DECK._x001C_ SEE SOLAS 74 AMENDED II-1/25-9.1
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Electrical
Issued 23 September 1996 Resolved
RENEW/REPAIR INOPERABLE EMERGENCY LIGHT LOCATED AFT PORT SIDE OF #6 DECK._x001C_ SEE SOLAS 74 AMENDED II-1/43.2.2
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Electrical
Issued 23 September 1996 Resolved
RENEW/REPAIR INOPERABLE EMERGENCY LIGHT LOCATED AFT OF THE PILOT HOUSE._x001C_ SEE SOLAS 74 AMENDED II-1/43.2.2
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Fire Fighting
Issued 23 September 1996 Resolved
RENEW AS ORIGINAL DETERIORATED FIRE MAIN HYDRANT LOCATED ON THE PORT BRIDGEWING._x001C_ SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Lifesaving
Issued 23 September 1996 Resolved
RENEW MISSING RETRO-REFLECTIVE MATERIAL TO THE PORT AND STBD LIFEBOATS. LIFEBOATS SHALL BE FITTED WITH RETRO-REFLECTIVE MATERIAL IN ACCORDANCE WITHSOLAS 74 AMENDED III/30.2.7 AND IMO RESOLUTION A.658(16)
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Accommodation/Occupational Safety
Issued 23 September 1996 Resolved
RENEW MISSING GASKETS TO NATURAL VENTILATION CLOSURES LOCATED ON THE PORT BOAT DECK._x001C_ SEE SOLAS 74 AMENDED II-2/48
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Construction/Loadline
Issued 23 September 1996 Resolved
RENEW/REPAIR INOPERABLE DOGS TO THE WATERTIGHT DOOR LOCATED AFT ON THE #4 DECK._x001C_
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Construction/Loadline
Issued 23 September 1996 Resolved
RENEW/REPAIR INOPERABLE DOGS TO THE WATERTIGHT DOOR LOCATED AFT ON THE #3 DECK.
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Electrical
Issued 23 September 1996 Resolved
RENEW/REPAIR INOPERABLE REMOTE SHUT-OFF FOR THE EMERGENCY GENERATOR FUEL TANK._x001C_ SEE SOLAS 74 AMENDED II-2/15.5
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996
Accommodation/Occupational Safety
Issued 23 September 1996 Resolved
RENEW/REPAIR INOPERABLE MAIN VENTILATION DOORS LOCATED ON THE PORT BOAT DECK. ENSURE ALL DOGGING BOLTS ARE PRESENT AND OPERABLE._x001C_ SEE SOLAS 74 AMENDED II-2/48/16
Condition: Unknown
Due 27 September 1996
Resolved 30 September 1996

Ownership record