Records from 1985 to 2001. Most recent: inspection, 29 May 2001.
Inspection history · 30
29 May 2001
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1065089
29 March 2000
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 816602
2 March 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1369562
4 March 1999
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1390961
25 August 1998
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 802549
20 July 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1375440
19 June 1998
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1473074
26 March 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1094030
5 March 1997
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1466995
21 October 1996
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1158706
9 October 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1431689
29 March 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1142895
8 March 1995
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1174611
4 March 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 853145
15 June 1993
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 835604
4 March 1993
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 842113
7 November 1990
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1224716
24 July 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 927751
23 May 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 926273
23 June 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1197251
13 June 1989
Deficiency Check · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1211982
23 May 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1206139
9 June 1988
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1199448
19 May 1988
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1352192
12 February 1988
MARPOL Annex II Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1021080
7 January 1988
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1009134
15 May 1987
Drydock Extension · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1334657
9 July 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1307563
19 May 1986
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1302182
28 May 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1291721
Electrical
Issued 2 March 2000
Resolved
Replace cracked wire on cargo pump electric cord controller.
Condition: Unknown
Due 2 March 2000
Resolved 2 March 2000
Deck/Cargo
Issued 2 March 2000
Resolved
Repair indicator on number 1 cargo transfer valve.
Condition: Unknown
Due 2 March 2000
Resolved 2 March 2000
Lifesaving
Issued 20 July 1998
Resolved
Replace or remove both life rings.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Deck/Cargo
Issued 20 July 1998
Resolved
Replace kerosene fuel station hose.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Deck/Cargo
Issued 20 July 1998
Resolved
Replace all mooring cables.
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Deck/Cargo
Issued 20 July 1998
Resolved
Ensure all hoses and header pipe is properly tested (hydro).
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Deck/Cargo
Issued 5 March 1997
Resolved
PROVIDE PROOF OF HYDRO DATE ON F/O TRANS. HOSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Deck/Cargo
Issued 5 March 1997
Resolved
REPLACE PORT FWR FACING WIRE.
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Deck/Cargo
Issued 5 March 1997
Resolved
INSTALL MISSING BOLTS ON FLANGES TO CARGO PIPING.
Condition: Unknown
Due 5 March 1997
Resolved 5 March 1997
Deck/Cargo
Issued 9 October 1996
Resolved
PROPERLY LABEL TANK TRUNKS "1,2 AND 3" TO MATCH VESSEL OIL SPILL RESPONSE PLAN.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Deck/Cargo
Issued 9 October 1996
Resolved
PROPERLY PRESSURE TEST CARGO PIPING PRIOR TO CONDUCTING CARGO OPERATIONS._x001C_
Condition: Unknown
Due 11 October 1996
Resolved 18 October 1996
Deck/Cargo
Issued 8 March 1995
Resolved
PROVIDE PROOF OF ANNUAL TESTING OF CARGO PIPING, FLEX HOSE, RELIEF VALVE AND PRESSURE GAUGE PRIOR TO CONDUCTING OIL TRANSFERS.
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Documentation
Issued 4 March 1993
Resolved
PROVIDE PROOF OF ANNUAL PRESSURE TESTING AND PROPER MARKING OF OIL XFER HOSE AND CARGO PIPING.
Condition: Unknown
Due 4 March 1993
Resolved 4 March 1993
Construction/Loadline
Issued 4 March 1993
Resolved
MARK HULL WITH VSL NAME AND DRAFT MARKS FORE AND AFT ON EACH SIDE OF VSL INCONTRASTING COLOR TO HULL.
Condition: Unknown
Due 4 March 1993
Resolved 4 March 1993
Deck/Cargo
Issued 24 July 1990
Resolved
STENCIL SERVICE AND MAXIMUM ALLOWABLE WORKING PRESSURE ON CARGO TRANSFER HOSES.
Condition: Unknown
Due 24 July 1990
Resolved 24 July 1990
Deck/Cargo
Issued 23 May 1990
Resolved
HYDRO TEST CARGO HOSES AND PIPING.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Documentation
Issued 23 May 1990
Resolved
ADD NRC TOLL-FREE PHONE NUMBER TO OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Deck/Cargo
Issued 23 May 1990
Resolved
PUMP WATER FROM BOW RAKE.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Fire Fighting
Issued 23 May 1990
Resolved
REPAIR/SERVICE FIRE EXTINGUISHERS.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Fire Fighting
Issued 23 May 1990
Resolved
PROPERLY MOUNT FIRE EXTINGUISHERS.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Construction/Loadline
Issued 13 June 1989
Resolved
CROP TO GOOD METAL AND RENEW: WASTED BOTTOM PLATING ON STBD SIDE #1 CARGO TANK; WASTED STBD SIDE SHELL PLATING PORT SIDE #1 CARGO TANK. AIR TEST IN THE PRESENCE OF A MARINE INSPECTOR TO PROVE REPAIRS.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Deck/Cargo
Issued 13 June 1989
Resolved
PROVE OR REMOVE STEAM PIPING.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Construction/Loadline
Issued 23 May 1989
Resolved
RENEW DRAFT MARKS, FOWARD AND AFT, BOTH SIDES (PAINT).
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Deck/Cargo
Issued 23 May 1989
Resolved
MAKE OIL TRANSFER PROCEDURES LEGIBLE.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Construction/Loadline
Issued 23 May 1989
Resolved
DOCK VESSEL, PRESENT BOTH END VOIDS AND 3 CARGO TANKS FOR INTERNAL INSPECTION. VESSEL TO BE IN A GAS-FREE STATE FOR CG INSPECTION. THE ABOVE TO BE COMPLETED TO THE SATISFACTION OF ATTENDING MARINE INSPECTORPRIOR TO 23JUN89.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Deck/Cargo
Issued 19 May 1988
Resolved
PERFORM ANNUAL TEST ON ALL CARGO HOSES AND TRANSFER PIPING.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Deck/Cargo
Issued 19 May 1988
Resolved
RENEW FLAME SCREEN TO THE NO. 1 CARGO TK PRESSURE/VACUUM VALVE.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Lifesaving
Issued 19 May 1988
Resolved
RENEW GRAB LINES ON STB RING BOUY.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Deck/Cargo
Issued 19 May 1986
Resolved
CONDUCT ANNUAL REQUIRED CARGO PIPING TEST.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Deck/Cargo
Issued 19 May 1986
Resolved
INSTALL DISCHARGE HEADER PRESSURE GAGE.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Deck/Cargo
Issued 19 May 1986
Resolved
CONDUCT ANNUAL CARGO HOSE TEST.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Deck/Cargo
Issued 19 May 1986
Resolved
PLUG OR CAP CONTAINMENT DRAIN.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Electrical
Issued 19 May 1986
Resolved
REMAKE WIRING CONNECTION TO "ALLEN BRADLEY" CONTROLLER FOR CARGO PUMP.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Deck/Cargo
Issued 19 May 1986
Resolved
CORRECT WORDING ON WARNING SIGN. ADD "NO OPEN LIGHTS"
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986